Tender For maintenance Of electrical installation In Nrb At Chandigarh. (Replacement Of Defunct Led Flood Light Fittings In Chandigarh College Of Architecture, Sec-12, Chandigarh).
Name of Work:- Mtc of EI in NRB at Chandigarh. (Replacement of defunct LED flood light fittings in Chandigarh College of Architecture, Sec-12, Chandigarh).
Sl. No.
Item Description
1
DSR 8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2
100 watt
3
150 watt
4
200 watt
5
Supply and Laying of following XLPE insulated and PVC sheathed, aluminum un armd. conductor cable of 1.1KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid on surface as required at site. The job include the cost of making connections with suitable size of Al. Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of Polycab / Havells / Finolex / RR Kabel / KEI / RPG / Universal/Grandlay make only.
6
Size 10 Sq.mm 4 core PVC Al. Arm. Cond. Cable
7
S/E of M.S. bracket (‘L’ shape) made from 40mmx40mmx 5mm thick angle iron to be installed on existing parapet / wall with the help of suitable size of nuts & bolts etc. for erection of metal halide flood light fitting. The job includes cost of painting of bracket with superior quality of paint and other all petty material etc. as required to complete the job.
8
S/E of Thermo Plastic cable Jn. Box IP55 of size 130 x 180 x 77 mm deep approximate with 4 nos. thermal block suitable for 1 no. incoming and 3 nos. outgoing cables. The terminal block shall be made of Hansel make KF-1010 H with terminal link or its equivalent make Wago/ Elmex/ Siemens only and cable junction box of make Hansel/ Legrand or its equivalent to IP55. The job includes all labour and petty material to required complete the job to the entire satisfaction of the Engineer in Charge of work. Please Enable Macros to View BoQ information