| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group A |
| 2 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3x1.5 sq.mm |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3x2.5 sq.mm |
| 4 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 5 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 6 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 7 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm) |
| 8 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.8 Module (125mmX125mm) |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet (3 module) |
| 13 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 14 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.6x6 sq.mm |
| 15 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 16 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 17 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . The DB and outgoing circuits must be properly labelled as specified by Engineer in Charge . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 18 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 19 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 20 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 21 | Supplying and fixing 6-32A , Four pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Supply and fixing of box type tube fittings (Batten & T8 LED Tube), complete with side holders and 18/20 watt 4 feet T8 LED tube etc, as required. |
| 23 | Supplying and making end termination of suitable size for the submain wiring with suitable lugs for 4 x 6 + 2 x 6 sqmm of PVC insulated copper conductor. |
| 24 | Removing Fan rod from cealing and handing over to EMU store safely as required. |
| 25 | Removing of Sheet Steel Enclosure including wires, pipes MCB etc. as required and making good the damage to the wall and covering using hylam sheet and handing over to the store/yard. Please Enable Macros to View BoQ information |