| 1 | WIRING |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 3 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 4 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 2.5 sq. mm |
| 7 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | 20 mm |
| 9 | 25 mm |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | 5/6 A switch |
| 12 | 15/16 A switch |
| 13 | 3 pin 5/6 A socket outlet |
| 14 | 6 pin 15/16 A socket outlet |
| 15 | 15/16A modular socket Three module |
| 16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 17 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 18 | 6 Module (200mmX75mm) |
| 19 | 8 Module (125mmX125mm) |
| 20 | Supplying and making end termination with copper reducer/bottle lugs/terminal lugs for following size of PVC insulated copper stranded cable of 1.1 KV grade as required. |
| 21 | 4 x 10 sq.mm + 2 x 6 sq.mm |
| 22 | 2 x 6 sq.mm + 1 x 6 sq.mm |
| 23 | DLP PVC Trunking |
| 24 | Supply and fixing of DLP Pastic Trunking 105x50mm with cover including all accessories (flexible cover (85 mm),end cap, junctions, joints, wall crossing, VDI accessories etc. as per site condition) |
| 25 | Supplying and fixing following modular switch/socket on existing modular plate, including connections etc. as required on the existing DLP trunking. |
| 26 | 5/6 A switch |
| 27 | 5/6 A socket outlet |
| 28 | Supply and fixing following modular support for mounting wiring accessories suitable for DLP trunking with 85mm cover plate |
| 29 | 6 module |
| 30 | MCCB, MCB & DB'S |
| 31 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 32 | 32 A TP&N |
| 33 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 34 | 4 way , Double door |
| 35 | 16 way, Double door |
| 36 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 37 | 4 way (4 + 12), Double door |
| 38 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | Single pole |
| 40 | Double pole |
| 41 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 42 | Supplying and fixing the following rating rating, 415 V, 10kA, 'C' curve miniature circuit breaker suitable for inductive load of Four Pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required. |
| 43 | 6-32A |
| 44 | EARTHING |
| 45 | Supplying and fixing 12 SWG copper wire on surface or in recess for loop earthing as required. |
| 46 | MV CABLE LAYING |
| 47 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 48 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 49 | Supply of 1.1 kV grade following rating, Aluminium conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required. |
| 50 | 2C x 10 sq.mm |
| 51 | MV CABLE JOINTING & END TERMINATION |
| 52 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 53 | 2 X 10 sq. mm (19mm) Please Enable Macros to View BoQ information |