| 1 | Taking down old unserviceable aluminium point wiring (light, fan, socket , power socket and bulk head fittings) from PVC/matelic conduit,on surface wiring, on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc complete all as specfied and directed. |
| 2 | M & L for modular point wiring for one light/one fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit having thickness not less than 1.8 mm thick (ISI Marked) with all accessories including suitable modular plate (Inner and outer) and modular metalic boxes of suitable sizes (for mounting switches/sockets/regulators etc) including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellgulators/ ceiling roses etc.)ow, Earth- Green) |
| 3 | All as per srl item No 2 above but for call bell point complete all as specified and directed. |
| 4 | All as per item no 2 above but for One 5 Amp modular socket outlet on independent board. |
| 5 | All as per item no 2 above but for One 5 Amp modular socket outlet on same board. |
| 6 | M & L for modular point wiring for one light/one fan controlled by one switch with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit having thickness not less than 1.8 mm thick (ISI Marked) with all accessories including suitable modular plate (Inner and outer) and modular metalic boxes of suitable sizes (for mounting switches/sockets/regulators etc) including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellgulators/ ceiling roses etc.)ow, Earth- Green) |
| 7 | M & L for replacement of existing un-serviceable switch piano with modular switch 1 way 6A, 1 module ISI marked complete all as specified and directed. |
| 8 | M & L for replacement of existing un-serviceable bell push piano type with modular bell push 1 way 6A, 1 module ISI marked complete all as specified and directed. |
| 9 | M & L for replacement of existing un-serviceable switch piano with modular switch 1 way 16A, 1 module ISI marked complete all as specified and directed. |
| 10 | M & L for replacement of existing un-serviceable socket with modular socket 16 amp AC 230 volts ,2 module ISI marked complete all as specified and directed. |
| 11 | M & L for replacement of existing un-serviceable socket with modular socket 6 amp AC 230 volts ,2 module ISI marked complete all as specified and directed. |
| 12 | M & L for ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 13 | Supply and fixing electronic bell ding-dong AC 230 Volts single pole complete all as specified and diercted. |
| 14 | Supply and fixing modular fan regulator step type 120W-2module |
| 15 | S & F for lamp holder/batton holder/angle holder insulated body with back bakelite plate suitable for batten fittings complete all as specified and directed. |
| 16 | M & L for Inverter LED batten with square profile and polycarbonate channel,lithium Ion battery with charging time 8 hours to 10 hours and back up time upto 4 hours of capacity 20 watt 230 volt,complete with all accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size mounting on rectangular PVC black complete all as specified and directed, |
| 17 | S&F LED Tube Light 20 watt LUMILINE Basic all purpose surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver. complete inicluding taking down old one as directed . |
| 18 | Supply & fixing LED Bulk head Sirius Series 10 W LED light. |
| 19 | S & F of sheet metal enclosures distribution boards, double door ,VTPN, 415 volts 4 ways (one incoming three phase & twelve out goings single phase )for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 16 KA=01 NO (for incoming ) (b) MCB SP 63 amps = 04 Nos (for outgoings) . ( Note :- (i)The DB shall be VTPN series. (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) cutting chasing shall be part of job at no extra cost . |
| 20 | Supply and fixing sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 12 ways complete all as specified and directed. |
| 21 | Supply and fixing sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 08 ways complete all as specified and directed. |
| 22 | Supply and fixing for MCB SPN 63 amps 240 Volt 'B' series complete all as specified and as directed. |
| 23 | Supply and fixing for MCB SPN 40 amps 240 Volt 'C' series complete all as specified and as directed. |
| 24 | Supply and fixing for MCB SP 6 to 32 amps 240 Volt 'B' series complete all as specified and as directed. |
| 25 | Taking down the unservicable /burnt sub main wiring from wooden batten and Supply & fixing for submain wiring in and including PVC conduit 1.8 mm thick ,32 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 10 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green) Please Enable Macros to View BoQ information |
| 26 | Taking down the unservicable /burnt sub main wiring from wooden batten and Supply & fixing for submain wiring in and including PVC conduit 1.8 mm thick ,32 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 10 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green) Please Enable Macros to View BoQ information |