| 1 | CIVIL WORKS |
| 2 | Dismantling door, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead:Of area beyond 3 Sqm |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.For thickness of tiles above 25 mm and upto 40 mm |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc including dismembering and stacking within 50 meters lead |
| 5 | KOTA STONE FLOORINGKota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 Coarse sand) |
| 6 | Providing and laying polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 7 | Providing edge moulding to 18 mm / 16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Extra for brick work with common burnt clay bricks / cement concrete bricks in superstructure above plinth level upto floor five level. |
| 10 | CEMENT PLASTER (IN FINE SAND)12 mm Cement plaster of mix:(1 cement : 4 fine sand) |
| 11 | Providing and fixing of steel doors double revated with gauge shutter all complete including hinges, tower bolt, locker and necessary handle including fitting all carriage complete job (Make Tata or Rivazo) |
| 12 | Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60±0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, DPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded to all corner, including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately).Note: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in this account shall be made.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm) |
| 13 | Providing and fixing 5mm thick toughened glass in UPVC windows including all accessories with all carriage. |
| 14 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work.Demolishing cement concrete manually / by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in-charge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 16 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in-charge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 17 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5, including getting out excavated earth and disposal of surplus excavated earth as directed:Ordinary Rock |
| 18 | CEMENT CONCRETE (CAST-IN-SITU)Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 19 | Providing and laying cement concrete in retaining walls, return walls, walls (Any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc. upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.1:2:4 (1 Cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) |
| 20 | Cement concrete flooring 1:2:4 (1 Cement :2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc complete |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc complete. Hot finished welded type tubes |
| 22 | C.G.I SHEETS ROOFINGProviding corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required, 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 23 | Providing and fixing of 10 mm thick puff panel including channel, all accessories complete, carriages, lead and lift (complete job). |
| 24 | Providing and fixing factory made UPVC white colour casement / casement cum fixed glazed windows comprising of UPVC multi-chambered frame, sash and mullion (hwere ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (White powder coated) casement handles, G>I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer road of required size and of approved quality, all complete as per approved drawing sealant shall be paid separately)Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm) |
| 25 | Providing and fixing 5 mm thick ACP sheet including rubble (Complete job). |
| 26 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick. |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work. |
| 28 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams / liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 29 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall suface |
| 30 | Carriage of Sand by Mechanical Transport av. Lead with in 55 km upto Tarakote including loading, unloading and stacking properly at site |
| 31 | Carriage of stone aggregate below 40 mm by Mechanical Transport av. Lead within 25 km upto Tarakote including loading, unloading and stacking properly at site. |
| 32 | Carriage of bricks by MT av. Lead within 60 km upto Tarakote including loading, unloading and stacking properly at site |
| 33 | Carriage of material by M.T Tarakote from Katra to Adhkuwari |
| 34 | Disposing of dismantled material lading unloading complete |
| 35 | ELECTRICAL WORKS |
| 36 | Wiring for light point / fan point / exhaust fan point / call being point with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. – Group – C. |
| 37 | Wiring for light / power plug with 2 x 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 38 | Wiring for light power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 39 | Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. |
| 40 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 41 | 2 x 6 sq. mm + 1 x 6 sq. mm earth wire |
| 42 | 2 x 10 sq. mm + 1 x 6 sq. mm earth wire |
| 43 | 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
| 44 | Supplying and drawing co-axial TV Cable RG -6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required. |
| 45 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required |
| 46 | 25 mm Conduit |
| 47 | 32 mm Conduit |
| 48 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Make: - Legrand (Mylinc) / Havell’s (Coral) |
| 49 | Modular Switch 5/6 Amp. |
| 50 | Modular Switch 15/16 Amp. |
| 51 | Modular Socket 3 pin 5/6 Amp. |
| 52 | Modular Socket 6 pin 15/16 Amp. |
| 53 | TV antenna socket outlet Modular |
| 54 | Modular Bell Push |
| 55 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make: - Legrand (Mylinc) / Havell’s (Coral) |
| 56 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Make: - Legrand (Mylinc) / Havell’s (Coral) |
| 57 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make: - Legrand (Mylinc) / Havell’s (Coral) |
| 58 | 1 or 2 Module (75 mmX75 mm |
| 59 | 3 Module (100 mmX75 mm) |
| 60 | 6 Module (200 mmX75 mm) |
| 61 | MCCB, MCB & DB’s |
| 62 | Providing and fixing following capacity TP&N dis-connector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.(Make: - Havell’s / ABB / Schinder / Legrand / L&T)100 Amps TP&N |
| 63 | Supplying and fixing following way, single pole and neutral , sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCC/Isolator) (Make: - Havell’s / ABB / Schinder / Legrand / L&T) |
| 64 | 8-way, Double door |
| 65 | 12-way, Double door |
| 66 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(Make:- Havell’s / ABB / Schinder / Legrand/L&T)4 way (4+12), Double door |
| 67 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:- Havell’s / ABB / Schinder / Legrand/L&T) |
| 68 | Single Pole |
| 69 | Single pole and neutral 40 Amp. |
| 70 | INSTALLATION, TESTING AND COMMISSIONING Supplying, installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc directly on ceiling / wall, including connections with 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required |
| 71 | LED Tube fitting 14-20 Watt 4 feet long. (Batten 4’) |
| 72 | LED Tube fitting 10 Watt 2 feet long ( Batten 2’) |
| 73 | LED Ceiling light 10-12 Watt (Round) |
| 74 | Bell Ding Dong |
| 75 | Supplying, Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required |
| 76 | Supplying, installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 77 | Upto 450 mm sweep (10”) |
| 78 | Upto 510 mm sweep H/D |
| 79 | Supply, Installation, testing and Commissioning of Geyser 35Ltr etc as required |
| 80 | Main Panel |
| 81 | Supply, Installation, testing and commissioning of panel 14/16 SWG CRCA fabricated and powder coated, compartmentalized panel with air ventilation and dust/vermin proof. = 01 No.(A) Main Incoming MCCBa) 200 Amp, 4P, 35 KA MCCB = 01 No.(Make:ABB,Schinder & L&T)b) LED RYB Indicators with MCB Protection = 01 Set(Make:C&S and GE)c) Ammeter with switch and voltmeter and frequency meter with switch (Make: AE) = 01 Setd) Bus Bars: 200 Amp, 43 Volt, 433 Volt, 4 Strips, Aluminium with heat shrinkable sleeves. = 01 Set(B) Outgoing MCCB’sa) 100 Amp, 16 KA MCCB 4-Pole. = 01 No.(Make:- ABB/ Schinder and L&T ) Please Enable Macros to View BoQ information |