| 1 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit.,GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed PS No.121 C |
| 2 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface complete with 1.5 sq. mm.FRLSH PVC insulated ultistrand copper conductor cable as earthwire drawn inside the conduit. piano type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect.PS NO.123C |
| 3 | Wiring Point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface,complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit., GP Box and piano type switch and socket etc. complete in all respect.PS NO.124C |
| 4 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed inthe wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. PS NO.138C |
| 5 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit.,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash.PS NO.140C |
| 6 | Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. and piano type switch and socket etc., complete in all respect including matching colour wash. PS No.141C |
| 7 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. PS NO.1149 |
| 8 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.PS No.1139 |
| 9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.DSR-2018 1.17.A) 3 x 1.5 sq. mm DSR-2018 1.17.3 |
| 10 | B) 3 x 2.5 sq. mm DSR-2018 1.17.12 |
| 11 | C) 3 x 4 sq. mm DSR-2018 1.17.21 |
| 12 | D) 3 x 6 sq. mm DSR-2018 1.17.30 |
| 13 | Supply and fixing of PVC corrugated conduits of 20 mm outer dia mtr. on surface as sleeving including all labour, T&P etc. required for proper completion of work as per direction and satisfaction of Engineer in charge.PS No.185 (II) |
| 14 | Supply and fixing of PVC corrugated conduits of 25 mm outer dia mtr. on surface as sleeving including all labour, T&P etc. required for proper completion of work as per direction and satisfaction of Engineer in charge.PS No.185 (III) |
| 15 | Supply and fixing of PVC corrugated conduits of 32 mm outer dia mtr. on surface as sleeving including all labour, T&P etc. required for proper completion of work as per direction and satisfaction of Engineer in charge.PS No.185 (IV) |
| 16 | Supply and fixing and concealing of 20 mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge.PS No 148A |
| 17 | Supply and fixing and concealing of 25 mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge.PS No 149A |
| 18 | Supply and wiring of submain with two number 10 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25mm dia heavy guage rigid steel conduit on surface, with one number 10 SWG copper earth continuity wire etc. complete in all respect. in 25 mm dia heavy duty (2 mm thick ) PVC conduit with one number 6 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.PS No.213C |
| 19 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. PS No.1413 CAT- AAA |
| 20 | S&F of 6 Amp to 32 Amp. SP MCB (10 KA) C Curve Ps No.1002 CAT A |
| 21 | S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve Ps No.1009 CAT A |
| 22 | S&F of 6 Amp. to 32 Amp. TP MCB (10 KA) C Curve Ps No.1013 CAT A |
| 23 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve CAT A PS No.1020A CAT A |
| 24 | S&F of 100 Amp 4 pole MCCB (25 KA) Thermal Magnetic release. Ps No.1021C CAT A |
| 25 | S&F of 250 Amp 4 pole MCCB (25 KA) Thermal Magnetic release. PS No.1021 G CAT A |
| 26 | S & F surface/Flush mounting 6ways V TPN distribution board without additional Door without DPX3 160 MCCB complete in all respect,as directed at site by Engineer in charge.PS No. 1030(D) Cat B |
| 27 | Supply of Top MS Channel 100x50x2240mm (2.5 Mtr long) as per design complete in all respects UPERC P-39 |
| 28 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. PS No. 627 |
| 29 | S&F of 200 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour,T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.PS No. 379 |
| 30 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other rameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 100 Amp MCCB -1 No Outgoning (a) 63 Amp. MCCB-2 Nos.Cat. B. Pannel Cubicle Type PS No.811(A) |
| 31 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.DSR 2018 13.10 Page No. 45 |
| 32 | Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. DSR 2018 , 13.11 Page No. 45 |
| 33 | S/f of 11 KV TPMO 9 Nos Insulator of Jai Shree / BHEl Make complete in all raspect as per direction of E/I UPERC Page No-48 |
| 34 | S/F of out door type 11 KV fuse set Relco/Rama /Azad make with insulator Jai Shree/BHEL Make complete in all raspects as per Direction of E/I (AOR) |
| 35 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : DSR-2018 120 Sq mm 10.5.2 |
| 36 | 240 Sq mm 10.5.3 |
| 37 | Supply of 185 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I. . (AOR) |
| 38 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required..(DSR elect 2018 Item.N. 8.3.2 Above 120 Sqmm and upto 400 Sqmm |
| 39 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :. (UPERC P-41) 185 Sqmm |
| 40 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. DSR Elect.2018/I.No. 1.15.1 |
| 41 | Repairing of transformer 63 KVA with replaced HV LV Coil , Bushing, Gasket set, injection Meaterial fresh transformer oil savita make & painting etc. Complete in all raspects (AOR) |
| 42 | Dis/ Re-erection of 63 KVA Al. wound outdoor type transformer as per ISS including fees as per direction of E/I (AOR) |
| 43 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS NO. 501. a) 70 Sq. mm 3-1/2 core |
| 44 | b) 50 Sq. mm 3-1/2 core |
| 45 | c) 35 Sq. mm 3-1/2 core |
| 46 | d) 16 Sq. mm 4 core |
| 47 | e) 16 Sq. mm 2 core |
| 48 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504. a) 70 Sq. mm |
| 49 | b) 50 Sq. mm |
| 50 | c) 35 Sq. mm |
| 51 | d) 16 Sq. mm |
| 52 | S & F surface/Flush mounting 6ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. PS No. 1027 A CAT A |
| 53 | Supply, Installetion, Testing & Commissioning of 450 mm dia 1400 R.P.M Exhaust fan with lovuvred shutters (AOR) |
| 54 | Supply, Installetion, Testing & Commissioning of 300 mm dia 900 R.P.M Exhaust fan with lovuvred shutters (AOR) |
| 55 | Supply of ceiling fan 1200 mm dia (ISI Mark) Make- Crompton/Havells/Bajaj/Usha or equivalent (AOR) |
| 56 | Supply and fixing of electronic fan dimmer, 300/400 watt, ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. PS No. 1203 |
| 57 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a)63 mm dia (OD-63 mm & ID-51 mm nominal) DSR-2018 14.15.1 |
| 58 | b)90 mm dia (OD-90 mm & ID-76 mm nominal)DSR-2018 14.15.2 |
| 59 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive &conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725(B) |
| 60 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. DSR2018, 12.42 |
| 61 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. DSR-2018 , 11.3.1 Above 4.5 metre and upto 6.5 metre |
| 62 | Above 8.0 metre and upto 10.0 metre DSR-2018, 11.3.3 |
| 63 | Above 10.00 metre and upto 12.00 metre DSR-2018, 11.3.4 |
| 64 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.DSR-2018 1.23. 2 way 5/6 A switch DSR -2018, 1.23.2 |
| 65 | 15/16 A switch DSR-2018, 1.23.3 |
| 66 | 3 pin 5/6 A socket outlet DSR-2018, 1.23.4 |
| 67 | 6 pin 15/16 A socket outlet DSR-2018, 1.23.5 |
| 68 | Bell push DSR-2018, 1.23.8 |
| 69 | 5/6 amps switch DSR-2018, 1.23.1 |
| 70 | Annual Maintenance of following type air conditioner as per attached term and conditions (AOR). 1.5 Tr. Window A.C. |
| 71 | 1.5 Tr. Split A.C. |
| 72 | fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect.PS No.1423 CAT- AAA |
| 73 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.PS No.1403 CAT- AAA |
| 74 | fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect. Ps No.1455 CAT- AAA |
| 75 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR-2018, 12.34 |
| 76 | S/F of Sintex type Juction box model No.IIGSJB2817 of Size 240x130x110 with way connector HDPE pipe 32 mm dia PE 100 PN-8 2 Nos 0.75 mtr MS Clamp with strip etc. Complete with all raspects as per direction of E/I (AOR) |
| 77 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 78 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 79 | Location and pin pointing of 11KV HT Cable fault exposing the same in the underground 11KV Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 80 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by expert technical staff. (AOR) |
| 81 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS No. 807 e (ii) 25 A TPN |
| 82 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. DSR Electricals 2018 No. 9.3a) 2 X 16/25 sq. mm (9.3.1) |
| 83 | 3.5 x 50 sq. mm (9.3.19) |
| 84 | 3.5 X 70 sq. mm (9.3.20) |
| 85 | Cement concrete with 4 cm auge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I. No. 5.07/S.N. 279 A |
| 86 | Cement concrete with 4 cm auge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I. No. 5.08/S.N. 281 |
| 87 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS No 647 |
| 88 | fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect PS No. 1422 AAA |
| 89 | Supply, Installation, Testing and commissioning of 1.5 Tr. Split type 3 star non-inverter air cooled A.C. unit consisting outdoor unit, indoor unit as detailed complete with standard factory supplied power and control coble, interconnection copper refrigerant piping insulated with insulation tubing as required as direction of E/I. (AOR) |
| 90 | Supply and fixing of Copper pipe insulating PVC Coated. Complete in all respects as per direction of E/I. (AOR) |
| 91 | Supply and laying of 2.5 sqmm x 3 core PVC Insulated Copper Cable. Complete in all respects as per direction of E/I. (AOR) |
| 92 | Cleaning of fountain pond including removing of mud grabage and washing with acid and bleching powder.complete in all respect. (AOR) |
| 93 | S/F of Stainless Steel Suction stainer complete in all respect. (AOR) |
| 94 | S/F LED Base Programmable colour changing water proof spot light power 24 watt. Complete in all respect. (AOR) |
| 95 | S/F. of MS Light Stand Powder Coated. Complete with all respect as per direction of E/I. (AOR) |
| 96 | S/F Cable 1.5 sqmm x 4 core round copper. complete in all respect.(AOR) |
| 97 | S/F Copper Cable of size 10 sqmm x 3 core. complete in all respect.(AOR) |
| 98 | S/F Foam jet nozzle of alluminium alloy engineering/ plastic epoxy coated.Complete in all respect. (AOR) |
| 99 | Annual maintenance Charges for 82.50 KVA DG Set with monthly visit of Service Engineer, Routine & Preventive Maintenance & Breakdown Service. Complete in all respects as per direction of E/I. (AOR) |
| 100 | S/F Lub Oil filter for 82.50 KVA DG Set. Complete in all respects as per direction of E/I. (AOR) |
| 101 | S/F Fuel filter, for 82.50 KVA DG Set. Complete in all respect in all respects as per direction of E/I. (AOR) |
| 102 | S/F Air Filter for 82.50 KVA DG Set. Complete in all respect in all respects as per direction of E/I. (AOR) |
| 103 | S/F Fuel Pipes for 82.50 KVA DG Set. Complete in all respect in all respects as per direction of E/I. (AOR) |
| 104 | S/F AVR 82.50 KVA DG Set. Complete in all respect in all respects as per direction of E/I. (AOR) |
| 105 | S/F Battery Charger 24 V DC 10 Amp Complete in all respect in all respects as per direction of E/I. (AOR) |
| 106 | S/F Hose Pipe. Complete in all respect in all respects as per direction of E/I. (AOR) |
| 107 | S/F Exhaust Silencer . Complete in all respect in all respects as per direction of E/I. (AOR) |
| 108 | Engine Safety Unit |
| 109 | Supply of Self Starter |
| 110 | Coolant |
| 111 | Mobil Oil |
| 112 | Repairing of 11KV Fuse wire/Jumper i/c supply & fixing of required size conductor, fuse wires of 11KV Line/DP Structure of Transformer by taking shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, Shoes and other necessary items. (AOR) |
| 113 | Pole Bus bar support connector 4 way with Backsheet. Completed in all respects. (AOR) Please Enable Macros to View BoQ information |