| 1 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS No 647 (Make : Bajaj/Philips/Crompton/Transline) |
| 2 | Supplying, installation, Testing & Commisioning of Standard 4 mtrs high (above ground) hot dip galvanized (glading of galvenisation average 70 micron or better as per IS2629 or equivalent) pole, with stiffener, chain allen bolt, post top fixture arrangement, foundation bolt, anchor plate template, nut and washers galvanized, factory finish, base plate of size 200 x 200 x 12mm etc complete as required. The pole shall be made of 3 mm thickness sheet with tolerance of +/- 5%. The column shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening a juction/looping box with heavy duty 3 phase 32 Amp connector with 16A DP MCB including al accessories complete as required.(Make &| model will be selected bt the client). (Make : Bajaj/Philips/Crompton/Transline) |
| 3 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect PS No. 1422 AAA. Warranty 5 Years (Bajaj/Philps/Havells/Crompton) |
| 4 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 ( Grandley, Gloster, Kalinga, Havells, Nicco, Plaza, KEI Make) i) 16 sqmm x 4 core |
| 5 | 50 sqmm x 3.5 core |
| 6 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504 16 Sqmm |
| 7 | 50 sqmm |
| 8 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. PS. No. 725 (B) |
| 9 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 716 |
| 10 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. (DSR Elect 2018/1.17.3/P-4) 3X1.5 Sqmm |
| 11 | S/F of Copper Cable of size 2.5 mm x 3 Core. Complete in all respect (AOR) |
| 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 90 mm dia (OD-90 mm & ID-76 mm nominal) DSR Electrical-18 pg-52, I.No.14.16.2. (Make-CPE/Duraline/Rex/Times/Narender Plast/Pioneer) |
| 13 | 63 mm dia (OD-63 mm & ID-50 mm nominal) DSR Electrical-18 pg-52, I.No.14.16.1. (Make-CPE/Duraline/Rex/Times/Narender Plast/Pioneer) |
| 14 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. E/I E/I DSR Electrical-2018. 12.38 |
| 15 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 e (ii) 25 A TPN |
| 16 | Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect. P.S. No. 628 |
| 17 | Supply & fixing of 5Amp to 32 Amp SP MCB (10KA) (Legand make) PS No. 1002 Cat (A) |
| 18 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 19 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate moorum screening, red bajri and labour required. i) bituminious portion (AOR) |
| 20 | ii) water bound macadam (AOR) |
| 21 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 22 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 23 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 24 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) Please Enable Macros to View BoQ information |