| 1 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : |
| 2 | All kinds of soil |
| 3 | All types of Ordinary rock including all types of laterite rock, blasting prohibited |
| 4 | Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 5 | Demolishing R.C.C. work including stacking of steel bars & disposal of unserviceable within 50 mts. lead. |
| 6 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 meters lead. |
| 7 | Dismantling steelwork in built up sections in angles, tees, flats and channels including all gusset plates bolts, nuts, cutting dismembering and staking within 50 mts. lead |
| 8 | Dismantling and removing mangalore roofing tiles from roofs including ridges, hips, valleys, sheets wind ties etc. but excluding battens, roof timber etc. and stacking materials within a distance of 50 mt. |
| 9 | Supplying and stacking of good earth at site including royalty and carriage upto 1 km. (earth measured in stacks will be reduced by 20% for payment). |
| 10 | Construction of embankement with approved material obtained from borrowpits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300-2 as per MORTH specification 305 |
| 11 | Supplying of laterite stone soling of size 150-200 mm size and murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power road roller including spreading, watering and consolidation of binding material etc.(Measurements shall be considered on finished item) . |
| 12 | Supplying and fixing Pre-cast cement concrete kerb stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. |
| 13 | a)Size 30 cm L x 50 cm H x 15 cm T |
| 14 | Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge A) 110 mm dia. |
| 15 | Providing and fixing Karatos (400x400) and 12mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 16 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. |
| 17 | All types of Ordinary rock including all types of laterite rock, blasting prohibited |
| 18 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 19 | Providing & laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded granitic or basaltic stone aggrt. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 20 | All works upto plinth level |
| 21 | Centering & shuttering including Strutting, Propping & removal of forms for : |
| 22 | Foundations, Footings, Bases for columns |
| 23 | Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like |
| 24 | Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan) |
| 25 | Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 26 | Suspended floors, roofs landings, shelves & their supports |
| 27 | Providing and laying in position ready mixed concrete (RMC) with usage of Ordinary Portland Cement manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineer-in-charge. All works upto floor V level |
| 28 | M-30grade of concrete |
| 29 | Extra for carriage of R.M.C. beyond the initial lead of 10 kms.Considering additional lead of 15 kms i.e. 47x15 |
| 30 | Providing corrosion resistant steel CRS-50 bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.)(Confirming to IS 1786 if 1985) for RCC work including bending, binding & placing in position in all the floors along with factory made precaste concrete cover blocks of specified s izes whose compressive strengthis not less than that of surrounding concrete in the structural member . |
| 31 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 32 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 33 | Exposed decorative laterite masonry using Patradevi stone of size as specified and laid as directed by architect in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 34 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 35 | Providing and filling in the sunken slabs with C.M 1:4 . Broken laterite soling stones to be laid in layers with mortar and top layer of I.P.S finish (1:2:3) over brickbat coba filling etc complete in all floors. |
| 36 | Pre-cast cement concrete solid block masonry of compressive strength 70 kg / cm2 in cement mortar 1:4 (1 cement : 4 corase sand ) in all sizes in superstructure from floor one level upto floor V level ( size of block 30x23x15) |
| 37 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. |
| 38 | b) Moorum |
| 39 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 40 | A) all works up to plinth level |
| 41 | 12mm cement plaster 1:4 (1 cement : 4 coarse sand) |
| 42 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 43 | 6mm cement plaster to ceiling 1: 4 (1 cement : 4 fine sand) |
| 44 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 45 | Applying one coat of cement primer of approved brand and manufacture on wall surface |
| 46 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 47 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 48 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 49 | Applying one or more 2 pack coats of epoxy zinc Phosphate primer on Steel Work of approved brand on New work to give an even shade.(Asian/Berger) |
| 50 | Painting two or more coats of Anti Corrosive 2 pack Epoxy finish paint on steel work of approved brand (asian) on New work to give an even shade. (Asian/Berger) |
| 51 | Providing and fixing vitrified matt finished (600x600) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 52 | Providing and fixing Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps and dados, jointing with grey cement slurry @3.3 kg per sqm, including pointing/grouting in white cement mixed with pigment of matching shade complete. |
| 53 | 600 x 600 mm - light Shades |
| 54 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm |
| 55 | Jet Black |
| 56 | Providing and fixing Aluminium shutters (Jindal make), 40mm series double openable shutters as per design including transportation, scaffolding and handling etc, complete. Windows with openable double shutters with outer frame 39 mm x 40 mm and shutters 54 mm x 40 mm with aluminium cleating system on SS 304 friction stay hinges, fixed mullion, single point locking, fixing screws of HILTI make with GP silicon. |
| 57 | Providing and fixing of Aluminium Window (Jindal make) 40mm series single openable shutter as per design, including transportation, and handling, with outer frame 39mm x 40mm and shutter 54mm x 40mm with aluminium cleating system on S.S 304 friction stay hinges, single point locking OR multi-point locking, 5mm clear annealed glass (ST. Gobain/AIS glass), fixing screw HILTI make and GP Silicon. |
| 58 | Extra for powder coating with pure polyester powder of shade of required colour on the aluminium section |
| 59 | Wood Finish Wood Core FRP (Fiber Reinforced Polymer) Door Shutter Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by using tray system with seasoned hard wood, moisture less than 17%, wooden styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) and printed matt having wooden textures used along with UV Resistant resin to give the clear texture on the door. The core of shutter will be filled with MR 2nd grade Block Board. The Shutter to be water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory. |
| 60 | Accessories: i) S. S. Hinges 4” - 3 Nos ii) S. S. Latch - 1 No iii) Tower Bolt 5” - 2 Nos iv) Handle 5” - 2 Nos |
| 61 | Shutter Thickness : a) 32mm |
| 62 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: |
| 63 | 110 mm dia |
| 64 | 75 mm dia |
| 65 | Fabricating and fixing of brush silver finish stainless steel box letters (4\\" box) cut to size as per the given design with grade SS 304 installed protruding 5cms from the existing wall surface and 450cms above the plinth level as per drawing including drilling of holes, fixing in position, fabricating, etc. completed. |
| 66 | Providing and fixing of Name plaque for a hand painted Logo of size 3.13m x 2.03m of tile size 6''x6\\" blue in color hand painted as per the design requirement including the charges for designing, hand painting, Tiles, artwork,etc. completed. |
| 67 | Supply installation testing and commissioning of 45W LED post top lantern of 5000K, Wipro make LP09s or Havels Spring 6LED POST TOP |
| 68 | Providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 69 | Supply installation testing and commissioning of Bollards with post (along the main road footpath)BROWN colored of height 1150mm complete with 60W,5000K led lamp with foundation bolts, CERCO Catalogue no Victoria (M) PL-01S |
| 70 | Sypply, installation testing and commisioning of Bollards without post (on the entrance/exit road gate-posts) ,BROWN colored complete with 60W,5000K led lamp and foundation bolts ,CERCO Catalogue no (L)GL-01 |
| 71 | Supplying and erecting integrated LED flood light fitting Max. 50W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No. FG ODF/FL |
| 72 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No. FG ODF/FL. |
| 73 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design 5m octagonal / conical GI pole).complete (for 3 to 5m octagonal / conical GI pole/Bol;lards etc). |
| 74 | Supplying & erecting GI flexible Conduit 50 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete in pole foundation |
| 75 | Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. |
| 76 | 3 Core 2.5 sq.mm |
| 77 | Supply of 4core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I),IS:7098(Part I) with latest amendments of following size. |
| 78 | (5) 4cx16 sq.mm |
| 79 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. |
| 80 | 4cx4sqmm |
| 81 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of trench as per Cable Trench drawing provided by the Engineer - Incharge, sand cushioning with screened sand bed of 20mm thick, protective covering with bricks placed lengthwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on top complete as required. |
| 82 | In rocky strata |
| 83 | Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. |
| 84 | In rocky strata |
| 85 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 86 | Supplying and fixing following way TPN sheet steel, double door, Vertical type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinbar detachable gland plate interconnections phosphatized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBs as required) |
| 87 | (d) 4 way (8+12), double door, Vertical type, Cat B |
| 88 | (e) 8 way (8+24), double door, Vertical type, Cat B |
| 89 | Supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with Supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having IP54, IK10 protection, 4 pole contactor upto 60A, with maintenance mode to switch ON street lights during time of repairs with energy consumption data recording for analysis and LCD display for energy monitoring with numeric keypad in provided box as per specification SW-STCP. |
| 90 | Supply installation of water tight Hensel make cable junction box of size 150x100x100mm |
| 91 | Supply installation and commisioing of waterpproof 60A 4way connetor |
| 92 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. |
| 93 | (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 94 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 95 | (g Group A -- with Cat C Modular Accessories |
| 96 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. |
| 97 | (b) Cat B |
| 98 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately). |
| 99 | (b) In rocky strata |
| 100 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately). |
| 101 | (b) In rocky strata |
| 102 | Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt) |
| 103 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 104 | Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required |
| 105 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing . as required |
| 106 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. |
| 107 | (2) 4 x 4 Sq. mm. |
| 108 | (5) 4 x 16 Sq. mm. |
| 109 | Supplying and erecting CRCA powder coated mirror light LED fitting (4 feet)Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V,surge protection of 4 kV, Life class of 50,000 Hrs at L70B50, IP 20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 110 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. |
| 111 | (f) SP, Cat B |
| 112 | (j) TPN, Cat B |
| 113 | Providing and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles1350 R.P.M. Oscillating type, plastic or metal blades chrome plated guard withregulator and moisture proof treatment to winding and with ‘E’ class insulation. Please Enable Macros to View BoQ information |