| 1 | Repairing/Replacement of existing wormout material of 02 Nos. of Hot Baine Marrie including Thermostate, Indicator , Rotary switch, element etc as per requirement including credit of old dismantle material. |
| 2 | Repairing/Replacement of existing wormout material of 02 Nos. of Four Door Refrigerator including Complete Unit with Wiring with temperature Control and on and off Switch, Door lead with Gas kit etc as per requirement including credit of old dismantle material. |
| 3 | Repairing/Replacement of existing wormout material of Display Counter Fridge including Condensor Fan Motor, Sub Zero with Wiring, Cooling Coil Fan etc as per requirement including credit of old dismantle material. |
| 4 | Repairing/Replacement of existing wormout material of 04 Nos. of Single Burner Cooking Range including Complete Burner Set and Pilot etc as per requirement including credit of old dismantle material. |
| 5 | Repairing/Replacement of existing wormout material of 02 Nos. of Chinese Cooking Range including Complete Burner Set and Pilot etc as per requirement including credit of old dismantle material. |
| 6 | Repairing/Replacement of existing wormout material of 02 Nos. of Hot Plate Burner including Complete Burner Set and Pilot etc as per requirement including credit of old dismantle material. |
| 7 | Rewinding, repair and servicing of following monoblock/ mono submersible pump set/ Centifugal Pump set / submersible pump set suitable for run 3 phase, 440volt, 50 Hz AC supply i/c replacement of bearing, seal, gasket etc.i/c dismental from existing location and carriage (to and fro) to the workshop and testing, commissioning with credit of scrap copper wire and other parts etc. as required. |
| 8 | 5 to 10 HP |
| 9 | 15 to 20 HP |
| 10 | Supplying Installation, testing and commissioning of 30 L Microwave Oven with Touch Controls, Defrost, Digital Display, voltage 220-240V, power 800 Watts, etc. complete as required |
| 11 | SITC of submersible/monoblock pump DOL control panel suitable for 3/5 HP 3 Phase having Ammeter, Voltmeter, Selector Switch, Single phase priventer complete with sheet steel enclosure, indicator light, ON/OFF push button, auto, manual switch i/c connection testing credit of old dismantle etc. as reqd. |
| 12 | SITC of 440V 50 Hz 3 Phase Star-delta starter panel suitable for 10 HP Open-well motor pump set having Ammeter, Voltmeter, Selector Switch, Single Phase Priventer etc. as reqd with credit of old dismentle material as reqd. |
| 13 | Supplying, Installation, testing and commissioning of 3 HP 415 Volt, Borewell submersible pump set capable of delivery of 1.6 LPS at the head of 60 meter directly coupled with submersible electric motor in the existing borewell i/c Gi pipe, nipple, flange, rubber gasket, nut bolt along with cable lowering making connection as reqd. i/c removing and dismantling the old pump set with testing and commissioning etc complete in all respect as reqd. |
| 14 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: |
| 15 | 65 mm dia |
| 16 | 80 mm dia |
| 17 | 150mm dia |
| 18 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required: |
| 19 | 80 mm dia |
| 20 | 150mm dia |
| 21 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 22 | 150 mm dia |
| 23 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 24 | 50 mm |
| 25 | SITC of 10 HP 440 Volt, 2900 RPM monoblock pump set capable of delivery of 1150 - 550 LPM at the head of 24-39 meter having suction and delivery 80 x 65 mm dia making connection & disconnection, removing and dismentling old pumpset with testing and commissioning as reqd. |
| 26 | Supplying, installation, Testing and Commissioning of Horizontal split casing Condenser water Centrifugal pump sets with CI Casing ,Bronze impller, Mechanical Seal, Carbon steel/stainless steel shaft, coupling, coupling guard complete with TEFC Squirrel cage induction motor with class 'F' insulations,IP 55 ,efficiency class IE2, operating on 415 +/-10% volts ,3 phase , 50 Hz A.C.supply and Mounting base frame work with anti vibration pads etc. complete as reqd including necessary flanges & reducers for suction & delivery pipe connections etc complete as required & as per following parameters i/ old dismantle material etc. as required. Capacity (LPM) --- 4542Pump Head (mtrs)--- 27.5 HP of motor --------- 50 HP |
| 27 | Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. as required. |
| 28 | 3 Core 4.0 Sq. mm Flat Cable |
| 29 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 30 | 250 Amp, 36KA, FPMCCB |
| 31 | supply, installation, testing and commissioning of MV compartmentalized type outdoor type double door cubical type panel board suitable for 3 phase 4 wire, 415 volts AC supply and having suitable size of front area and 400 mm deep nominal size fabricated out of 2 mm thick CRCA sheet dust & vermin proof hinged type openable door, locking arrangement i/c 3mm thick sheet in bottom for gland plates, supplying and fixing following accessories as mentioned below i/c 400 Amp Aluminium bus bar inter connection, arrangement for cable entry/support/termination 2 Nos. earthing stud inter connection with 25 mm x 5 mm Copper strip (externally), 50mm x 50mm x 5mm MS angle iron base frame duly welded 500mm long, 4 Nos. legs for grouting in foundation i/c painting, Pdg. Of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (300mm |
| 32 | below the ground level and 300mm above the ground level) it should be covered with Aprin plate (300mm above the ground) not less than 3mm thick etc. complete as required, including dismantling and buyback of existing old damaged panel with connection of cables etc as required. (Design shall be approved by Engineer in Charge). |
| 33 | Supplying, Installation, Testing and Commissioning of following switch gear and accessories in the existing cubical panel board as reqd. |
| 34 | Incoming |
| 35 | 250 Amp, 36 KA, FPMCCB with Rotary handle & Spreader as Incomer |
| 36 | 125 Amp, 36 KA, FPMCCB |
| 37 | 100 Amp, 30 KA, FPMCCB |
| 38 | Digital type ampere Meter of 0-100 Amps. Range with selector switch CT 100/5 15VA for amps. (3 Nos.) |
| 39 | Digital type voltmeter of 0-600 volts range with selector switch |
| 40 | Phase indicating lamps (LED type) with toggle Switches |
| 41 | Anodised Al. MV danger notice Plates and phenolic labeling as reqd. |
| 42 | supply, installation, testing and commissioning of MV compartmentalized type indoor type single door cubical type panel board suitable for 3 phase 4 wire, 415 volts AC supply and having suitable size of front area and 400 mm deep nominal size fabricated out of 2 mm thick CRCA sheet dust & vermin proof hinged type openable door, locking arrangement i/c 3mm thick sheet in bottom for gland plates, supplying and fixing following accessories as mentioned below i/c 400 Amp Aluminium bus bar inter connection, arrangement for cable entry/support/termination 2 Nos. earthing stud inter connection with 25 mm x 5 mm Copper strip (externally), 50mm x 50mm x 5mm MS angle iron base frame duly welded 500mm long, 4 Nos. legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (300mm below the ground level and 300mm above the ground level) it should be covered with Aprin plate (300mm above the ground) not less than 3mm thick etc. complete as required, including dismantling and buyback of existing old damaged pannel with connection of cables etc as required. (Design shall be approved by Engineer in Charge). |
| 43 | Supplying, Installation, Testing and commissioning of following switch gear and accessories in the existing cubical panel board as reqd. |
| 44 | Incoming |
| 45 | 250 Amp, 36 KA, FPMCCB with Rotary handle & Spreader as Incomer |
| 46 | Digital type ampere Meter of 0-100 Amps. Range with selector switch CT 100/5 15VA for amps. (3 Nos.) |
| 47 | Digital type voltmeter of 0-600 volts range with selector switch |
| 48 | Phase indicating lamps (LED type) with toggle Switches |
| 49 | Supplying & Laying following size XLPE insulated and PVC sheathed Al. conductor armoured power cable of 1.1 KV grade in existing DWC / GI / pipe / on surface or loose for connection and testing etc as reqd. |
| 50 | 3.5 x 95 Sq. mm |
| 51 | 3 x 10 Sq. mm |
| 52 | providing & fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as reqd. |
| 53 | providing & fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as reqd. |
| 54 | Supplying and making end termination with brass compression gland and Al. lugs for following size of PVC insulated and PVC sheathed/XLPE Al. conductor cable of 1.1 KV gradeas reqd. |
| 55 | 3.5 x 95 Sq. mm (45mm) |
| 56 | Supply, Installation, Testing & Commissioning of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 25 mm dia. and l0 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm tested by CPRI capable of bearing fault current of 25 kA. Along with earth enhancement compound (jam plus) tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 50 kg ( 10 kg Bag x 5) resistivity is less than 0.12 ohm meter . The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement including cost of petty material required to complete the job in all respect. |
| 57 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+,brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc.as required. |
| 58 | 42 inch or larger |
| 59 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Preassembled shelves in multiple configurations, Rubber fibre slotted bracket built-in, metal splice shelf to protect the fibres, 2fiber spools built-in for 900μm tight buffered fibre storing, Capable of storing up to 3 meters of 900μm tight buffered fibre per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. |
| 60 | 12 Port LIU |
| 61 | Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control, White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates:- Triple streaming, configurable Main stream: 4MP (2560×1440)25/30fps, Sub streams minimum: 720P @ 25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. |
| 62 | 9) On board Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)-to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 63 | 4MP @ 25/30fps @1440P (2560x1440) Dome Camera with 2.7mm ~13.5mm Motorized lens, Vari Focal (view Angle for H: 104°–29°; V: 54°–16°; D: 125°–34°) |
| 64 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support |
| 65 | 3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nos USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Alert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempering, network disconnection and panic11) Web & Mobile Application: Web, Mobile app (For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF 21.12 (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS and BIS Certified14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing) 16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×76821) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode |
| 66 | 23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behaviour of fan 28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, pre-sets and email.29) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. |
| 67 | 33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behaviour of fan, cybersecurity exception34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, pre-sets and email.35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics |
| 68 | 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 69 | Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 70 | 10 TB (Terabytes) |
| 71 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5 Kg |
| 72 | 1 Run of cable |
| 73 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10GBase -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP/ MLD Groups 1K or more, IPv4/ IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN:802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN,VLAN Trunking, DHCP Snooping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict + WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/ UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp,802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL,SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 74 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each cooper port supporting 802.3at PoE+ min. |
| 75 | Supply and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U' Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 76 | 9U Rack |
| 77 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.. i) 25 mm dia . |
| 78 | Supplying and laying of HDMI cable with Ethernet male A to male A connector with 48 GBPS Transmission Ultra High Speed Compatible with All HDMI-Enable Devices Supporting Auto Low Latency Mode (ALLM), complete, etc. as required. |
| 79 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D |
| 80 | Copper Patch Cords of length 1m (3ft) |
| 81 | Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature). Non Inverter Type |
| 82 | 1.5 TR with minimum 3 Star BEE rating |
| 83 | Credit for old dismantle items |
| 84 | Assorted oven |
| 85 | Assorted Valve/NRV Please Enable Macros to View BoQ information |