| 1 | Supplying and replacement of existing old tubular pole by HOT Dip galvanized octagonal steel pole of 10 mtr height made out of 3 mm thick sheet having bottom 210 mm A/F & top 90 mm A/F with built in connector control box with flush cover on height of 1000 mm from the bottom of pole, PCD 320 mm, MS base plate of size 320 mm x 320 mm x 20 mm thick with 250 mm strip in octagonal shape(anti theft arrangement), the pole is to be fixed on existing RCC foundation with bolt and nuts making connection, interconnection with thimble/ lugs in the connector box, earthing, making/ numbering of pole etc as required with following accessories with mounted in built in control box. a) 6 mm thick laminated sheet along with 2 nos. 6 Amp, 10KA, SPMCB, 'C' charcteristic on the din channel, 2 no. 63 Amp terminal block suitable for 25 sq.mm Aluminum condr. cable and din channel for MCB's.b) Earth stud weld at suitable height i/c washer, spring washers and nuts.c) Cable support clamps suitable for 2 nos. of 2x 16 sqmm Cable.d) Hot dipped galvanized channel type bracket suitable for mounting upto 4 nos fixture lightings with nut bolt and suitable canopy.e) Drawing of pole and bracket shall be approved from the engineer incharge as per manufacturer before use at site. ( The rate is inclusive of rebate) |
| 2 | Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 500 mm long x 500 mm wide and 1600 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1650mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-10 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 750 mm long (150 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 26 mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.) |
| 3 | Supplying and replacement of existing old tubelor pole by HOT Dip galvanized octagonal steel pole of 7 mtr height i/c dismantling of existing old /rusted pole, made out of 3 mm thick sheet having bottom 130 mm A/F & top 70 mm A/F with built in connector control box with flush cover on height of 500 mm from the bottom of pole , MS base plate of size 220 mm x 220 mm x 12 mm thick with 250 mm strip in octagonal shape(anti theft arrangement), the pole is to be fixed on existing RCC foundation with bolt and nuts making connection, interconnection with thimble/ lugs in the connector box, earthing, making/ numbering of pole etc as required with following accessories with mounted in built in control box. a) 6 mm thick laminated sheet along with 2 nos. 6 Amp, 10KA, SPMCB, 'C' charcteristic on the din channel, 2 no. 63 Amp terminal block suitable for 16 sq.mm Aluminum condr. cable and din channel for MCB's.b) Earth stud weld at suitable height i/c washer, spring washers and nuts.c) Cable support clamps suitable for 2 nos. of 2x 16 sqmm Cable.d) galvanized steel 500mm single arm bracket made out of suitable mm dia pipe with canopy suitable mm as required and suitable for LED fitting etc. as required.e) Drawing of pole and single arm bracket shall be approved from the engineer incharge as per manufacturer before use at site.(rebate for old dismantled MS pole is inclusive in the rate and dismantled pole shall be the property of the agency and agency should quote the rates accordingly i/c rebate ) |
| 4 | Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 400 mm long x 400 mm wide and 1400 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1600 mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-8 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-16 x 450 mm long (100 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 200 mm x 200 mm x 3 mm thick having 4 Nos. suitable mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.) |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq.mm |
| 6 | Supply of PVC sheathed & XLPE insulated armoured aluminium conductor power cable (As per IS 7098 (Part-1) of 1.1 KV grade i/c connection testing etc.as required. 2 x 10 sq. mm |
| 7 | 4 x 50 sq. mm |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63mm & ID-51 mm nominal) |
| 10 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 11 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10sq. mm (19mm) |
| 12 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 72 Watt |
| 13 | Supplying, Installation, Testing & Commissioning of 200 Watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Please Enable Macros to View BoQ information |