Name of Work:- REPAIR/MAINT/IMPROVEMENT OF VCB, RMU ALONGWITH ALLIED HT INFRASTRUCTURE AT AF STN SIRSA UNDER GE (AF) SIRSA
Sl. No.
Item Description
1
Material and labour for replacement of Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and as directed by Engr-in-Charge.
2
Material and labour for Servicing of Vacuum Circuit Breaker and calibration of HT VCB panel including VCB 800/630/400 Amps, after taking proper shut down and disconnecting the cables from panel and VCB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of VCB isolating contacts, rewiring of burnt out/unsv VCB panel wiring complete, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/outgoing cable and necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of burnt out/defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc., under the supervision of expert technician of ground or authorised dealer/ representative, and refixing the panel in its original position with complete painting of VCB Panel and testing entire satisfaction of Engineer -in- Charge .
3
Material and labour for Servicing of Vacuum Circuit Breaker and calibration of HT VCB panel including VCB 800/630/400 Amps, after taking proper shut down and disconnecting the cables from panel and VCB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of VCB isolating contacts, rewiring of burnt out/unsv VCB panel wiring complete, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/outgoing cable and necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of burnt out/defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc., under the supervision of expert technician of ground or authorised dealer/ representative, and refixing the panel in its original position with complete painting of VCB Panel and testing entire satisfaction of Engineer -in- Charge .
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.