| 1 | M&L for painting of steel tubler LT pole any type any description including cross arm bracing with one coat of white silver colour , including the marking of pole no all as directed. |
| 2 | M&L for earthing complete with galvanized steel pipe electrode,40mmbore,medium grade,2.5 Mtrers length,buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground leavle cinnected with earthing lead of 4mm dia galvanised iron or steel wire all as shwn in Plate no-2 to the earthing test point all as specified and indicated including testing on completion. |
| 3 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.(For all installation transformer) |
| 4 | Supply and laying GI tubing 50 mm dia light grade for cable protection all as directed. |
| 5 | Supply and laying GI tubing 80 mm dia light grade for cable protection all as directed. |
| 6 | Dismantling and taking down MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed. |
| 7 | Fixing only MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed. |
| 8 | M&L cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated or directed complete incl painting ( one red oxide primer coat two coats of aluminium paint ) complete. |
| 9 | Supply and fix GI strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductorsand down conductors above ground all as directed. |
| 10 | Dismentling / Taking down old Aluminium conductor steel rainforced any type and size. |
| 11 | Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections etc all as specified & directed. |
| 12 | Re-Fixing/re-stringing Aluminium conductor steel reinforced of any type and size on existing steel tubular / PCC poles including winding, jumpering with alkathine pipe etc complete all as specified and as directed. |
| 13 | Dismantling and taking down insulators of any size from dismantled/existing LT poles of any type or description complete all as specified and directed. |
| 14 | M & L for LT insulator, PIN type 1100 volts as per IS 1445, grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed. Make;- Elpro or equivalent. |
| 15 | Fixing only LT insulator, PIN type, 1100 volts grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed. Make;- Elpro or equivalent. |
| 16 | Excavation in trenches Soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all as specified and directed. |
| 17 | Excavation in trenches for errection of poles etc.,n. exc 1.5m wide, exc 1.5m and n. exc 3.0m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 18 | Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed. |
| 19 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed. |
| 20 | Demolition of PCC coping , base , etc any type any location all as directed. |
| 21 | M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 22 | M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed. |
| 23 | Supply and fixing MCCB 400 Amp, 3/4 pole, 415 V,with breaking capacity 25 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.Make :L&T/havells/Legrand |
| 24 | Supply and fixing MCCB 250 Amp, 4 pole, 415 V,with breaking capacity 25 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.Make :L&T/havells/Legrand |
| 25 | Supply and fixing MCCB 200 Amp, 3/4 pole, 415 V,with breaking capacity 25 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.Make :L&T/havells/Legrand |
| 26 | Supply and fixing MCCB 160 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.Make :L&T/havells/Legrand |
| 27 | Supply and fixing MCCB 125 Amp, 3/4 pole, 415 V,with breaking capacity 16 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.Make :L&T/havells/Legrand |
| 28 | Supply and fixing MCCB 100 Amp, 3/4 pole, 415 V,with breaking capacity 16 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.Make :L&T/havells/Legrand |
| 29 | Supply and fixing MCCB 63 Amp, 3/4 pole, 415 V,with breaking capacity 10 . Make : Belno/havells/Legrand |
| 30 | Supply and fixing MCB 6 - 40 Amp, 2 pole, 220 V,with breaking capacity 10 KA . Make : Belno/havells/Legrand |
| 31 | M & L in repair HDPE DWC pipe 40 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection all as directed. Make:-Infra/Supreme/Prince |
| 32 | M & L in repair HDPE DWC pipe 50 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection all as directed. Make:-Infra/Supreme/Prince |
| 33 | Supply installation fabricated MS ring suitable for fixing six/five number flood light on top portion of MS pole.Note:- The rate including the fixing arrangement of light fitting complete all as directed. |
| 34 | Taking down the unserviceable light fitting any type, supply and fixing Flood light(SMD Type) 120 watt with high pressure die cast housing with IP66,surge protection light netural warm white, all as directed. make:Benlo,Havells, Philips Please Enable Macros to View BoQ information |
| 35 | Taking down the unserviceable light fitting any type, supply and fixing Flood light(SMD Type) 120 watt with high pressure die cast housing with IP66,surge protection light netural warm white, all as directed. make:Benlo,Havells, Philips Please Enable Macros to View BoQ information |