| 1 | M&L for site clearence in soft / loose soil including cleaning away all grass, vegetation, sapling, shrubs, brushwood, undergrowth, roots and trees not exceeding 30cm girth (measured one meter above ground level) and removing rubbish up to a distance of 50 m outside the periphery complete all as specified and directed. |
| 2 | Excavating over areas, n exc 1.5m deep & getting out in hard / dense soil complete all as directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed. |
| 4 | M & L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M&L for hard core of broken stone or boulder, gauge n exc 63mm deposited spread and leveled in layers n exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 6 | M&L for precast cement concrete block masonary build with solid block of PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) exceeding 10 cm in width , set in cement mortar 1:6 complete all as specified and directed. |
| 7 | M & L for 100 mm thick PCC 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub- base floor finished the surface fair and rough to receive subsequent layer with and including necessary formwork complete all as specified and as directed. |
| 8 | M& L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in foundation for post and similar work complete all as specified and directed. |
| 9 | M&L for RCC 1:1.5:3 type A1 (20mm graded aggregates) as in foundation, footing, mass concrete, foundation beam, plinth beam and base for column complete all as specified and directed. |
| 10 | M&L for RCC 1:1.5:3 type A1 (20mm graded aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 11 | Use & waste for flat formwork to sides of concrete foundations, footings, bases of columns raft and raft beams, sides and soffits if any of foundations and plinth beams and similar work, etc, rough finished surfaces of concrete etc all as specified and directed |
| 12 | Use & waste for flat form work to sides of pillars, posts struts, piers columns and stanchions, square, rectangular or polygonal rough finished surfaces of concrete etc all as specified and directed |
| 13 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | S&F TMT bars 5 mm to 10mm dia as in stirrups / spacers / binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | M & L for rendering 15 mm thick cement plastering on wall surfaces in two layers (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 16 | Supply only liquid water proofing compound complete all as specified and directed. |
| 17 | Returning filling in including spreading leveling watering and well ramming in layers n exc 25cm complete all as specified and directed. |
| 18 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as specified and directed. |
| 19 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 20 | S&F rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe 410-W(Gde E-250) Quality B complete all as specified and directed. |
| 21 | S&F mild steel Plates (plain or chequered) channels, square cut or notched(ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W(Gde E-250) Quality B complete all as specified and directed. |
| 22 | S&F Pre- painted galvalume aluminum zinc coating Gl based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall of mangalore pattern design, fixed with self tapping screws as specified & directed. |
| 23 | S&F Pre- painted galvalume aluminum zinc coating Gl based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall of mangalore pattern design, fixed with self tapping screws as specified & directed. |
| 24 | S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410- W(Gde-E-250) quality -A complete all as specified and directed. |
| 25 | S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed. |
| 26 | S & F rolled mild steel hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming toFe-290 Gde E-165 complete all as specified and as directed. |
| 27 | M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed |
| 28 | S&F for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders; framed balusters; walk ways; railings, framework of water tanks and similar work conforming to Fe.290. Gde-E-165 complete all as specified and directed. |
| 29 | S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides and hanging; also fastening and fixing complete conforming to Fe.290. Gde-E-165 complete all as specified and directed. |
| 30 | S&F Mild steel screw bolts (machine made) 11 to 15mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm and n exc 10cm long complete all as specified and directed. |
| 31 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrom primer, complete all as specified and directed. |
| 32 | S&F mild steel galvanised PVC coated chain link fencing, 3.15 mm nominal dia of GI wire, 1.4 mm thick PVC coating and average area of aperatus 25 sqcm with weight of chain link not less than 3.00 Kg / Sqm complete all as specified and directed. |
| 33 | S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 34 | S&F of 20 mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as specified and as directed. |
| 35 | S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all complete all as specified and directed. . |
| 36 | Supply, installation, testing and commissioning of pop up spray head, 4\\" (102mm) pop up height, , full circle 360 degree, dual spray pattern nozzle, with 1/2 \\" FNPT inlet, adjustable spray radious 8-15 ft, operating pressure 15-70 psi, UV resistant, plastic body with stainless steel spring, pressure activated wiper seal, ratcheting mechanism for alignment and removable top serviceable internal parts including all accessories, necessary excavation, connection to lateral line, flushing commissioning and making good complete all as specified and directed.(Make: Model No.1804 FDS of Rain Bird / Model No. PROS-04-CV of Hunter / Model No. PRO-S of K-Rain or as approved by GE.) |
| 37 | Supply, installation, testing and commissioning of submersible pump set 3.00 HP, single phase, water cooled, suitable for continious duty operation on 180-240 volts supply having cast iron body, dynamically balanced impeller, stainless steel shaft with bearings, capable of delivering discharge upto 100LPM against head 20-40 m, with and including suitable control panel for off on (DOL starter), submercible power cable ( 2.50 Sqmm flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible pump Motors 1100 Volt, conforming to IS 694, Minimum length shall be 10 M.) fixing arrangements, electrical connections including making good disturbed surfaces complete all as specified and directed. |
| 38 | Supply, installation, testing and commissioning of central foam jet fountain nozzle, heavy duty, stainless steel / brass, corrosion resistant, 1\\" BSP connection, design to deliver a stable, frothy water column of 2.5-3 m height, operating pressure 1.50 - 3.00 bar, suitable for outdoor decorative fountain in the centre of locations including necessary flow straightner, clamps, piping alignment, connection to pump by all electrical connection including making good disturbed surfaces complete all as specified and directed. |
| 39 | M & L for 75 mm thick PCC 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub- base floor finished the surface fair and rough to receive subsequent layer with and including necessary formwork complete all as specified and as directed. |
| 40 | M & L Machine pressed precast concrete interlocking paver block any shape prepared with grey cement and pigment of size confirming to IS 15658-2006 of 60 mm thick M-35 Grade laid over sand cushioning layer complete all specified and directed. (Note: Sand cushioning shall be measured and paid in relevant item.) |
| 41 | M&L for sand filling under floors or in foundations including watering and consolidation for cushioning complete all as specified and as directed. |
| 42 | M & L for 75 mm thick PCC 1:3:6, type C2, (using 40mm graded stone aggregate) as in base of kerbstone and including necessary formwork complete all as specified and as directed. |
| 43 | M&L Stone kerb of machine pressed rubber moulded precast cement concrete of M-25 grade , using 20mm graded stone aggregate, block of size 45cmX30cmX15cm finished at top bullnosed shape and finished surface even and smooth using coloured pigment and jointed in CM 1:3 struck finished as directed. |
| 44 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed. |
| 45 | M&L for preparing the concrete surfaces of kerb stone applying two coats of synthetic enemel paints in zebra pattern over a coat of primer complete all as specified and as directed. |
| 46 | M&L for 18 to 20 mm thick granite (of any type and colour) tiles machine cut as in floors jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing with and including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.(Note: The colour / shade / design of granite shall be as approved by GE(I).) |
| 47 | M&L for preparing new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 m/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as ecommended by the manufacturer all as specified and as directed (Note : Rate shall be included for necessary scaffolding and safety measures where required at site ). |
| 48 | Supply and laying of pea gravel of 10mm size as in children play area complete all as specified and directed. (Loose volume shall be measured for payment purpose) |
| 49 | Supply, plantation and developing of carpet Grass including necessary earthwork and excavation to achieve a depth of 30 cm in any type of soil, removing the roots and vegetation and filling of the excavated area with good earth (red soil) mixing with cow dung and vermi compost and watering etc and applying soil pesticide complete all as specified.Notes: (i)Layout plan for lawn/plants/hedges/grass shall be submitted and get its approval from GE (I) before the execution of respective items.(ii) Cost of manure, good soil, pesticides etc. shall be measured and paid separately under relevant items. |
| 50 | Supply and plantation of Royal palm (height of plant not less than 10 feet above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed by the Engineer-in-charge.Note: (i)Layout plan for lawn/plants/hedges/grass shall be submitted and get its approval from GE (I) before the execution of respective items.(ii) Cost of manure, good soil, pesticides etc. shall be measured and paid separately under relevant items. |
| 51 | Supply and plantation of Temple Tree (height of plant not less than 10 feet above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed by the Engineer-in-charge.Note: (i)Layout plan for lawn/plants/hedges/grass shall be submitted and get its approval from GE (I) before the execution of respective items.(ii) Cost of manure, good soil, pesticides etc. shall be measured and paid separately under relevant items. |
| 52 | Supply only approved loose soil best quality for plantation |
| 53 | Supply only approved manure (cow dung) best quality |
| 54 | Supply only approved vermi compost best quality |
| 55 | (Note for Serial item No. 49, 50 & 51 : During defect liability period contractor shall look after the plants / tree by deputing one malli , who will watering the plants / tree, provide manure if requirred , loosing the earth near root of tree as requirred without any extra cost to the Govt.) Please Enable Macros to View BoQ information |