| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. |
| 2 | Excavation in trenches n.exc 1.5m wide and exc 1.5 m but n.exc 3.0 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge. |
| 4 | Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge. |
| 5 | M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge. |
| 6 | M&L for broken bricks Loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells etc., complete all as specified and as directed. |
| 7 | M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete with necessary formworks (as/if required), complete all as per specified and as directed by Engineer-in-charge. |
| 8 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in surface channels and drains with necessary formwork and finishing concrete surfaces even and smooth with using extra cement, including demolition of existing old damaged PCC drains, complete all as specified and as directed by Engineer-in-charge. |
| 9 | M&L for precast reinforced cement concrete 1:2:4, type-B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes, etc.) and similar articles with plain faces and set in cement mortar 1:4, including demolition of existing old damaged RCC, complete all as per specified and as directed by Engineer-in-charge. NOTE : Reinforcement will be measured and paid separately under relevant Item. |
| 10 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, incl demolition of existing B/W,complete all as per specified and as directed by Engineer-in-charge. |
| 11 | M&L for Rendering 15mm thick in cement morter 1:4 on brick work or concrete surfaces, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge. |
| 12 | S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge. |
| 13 | M&L for providing 100 mm thick Cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including filling joints with bitumen and sand mixture of 1:3, use and waste of form work and finishing concrete surfaces even and fair and demolition of existing old damaged PCC of any type, complete all as per specified and as directed by Engineer-in-charge. |
| 14 | M&L for providing 75mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including filling joints with bitumen and sand mixture of 1:3, use and waste of form work and finishing concrete surfaces even and fair and demolition of existing old damaged PCC of any type, complete all as per specified and as directed by Engineer-in-charge. |
| 15 | M&L for providing glossy finished Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors., laid over 20mm thick cement screed 1:6 with grey cement and pigments to match, including dismantling the existing old unserviceable tiles of any type and of any description, complete all as per specified and as directed by Engineer-in-charge. |
| 16 | M&L for providing Machine pressed precast coloured concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, with grey cement and pigment, including dismantling the existing old unserviceable paver block of any type and of any description, complete all as per specified and as directed by Engineer-in-charge. |
| 17 | M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, including dismantling the existing old unserviceable tiles of any type and of any description, complete all as per specified and as directed by Engineer-in-charge. |
| 18 | M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 350x 250x 7/ 300x 450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, including dismantling the existing old unserviceable tiles of any type and of any description, complete all as per specified and as directed by Engineer-in-charge. |
| 19 | S&F in-repair of 20mm dia (Outer) CPVC pipes SDR 11.5 & Plain CPVC SDR 11.5 fittings fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge. |
| 20 | S&F in-repair of 25mm dia (Outer) CPVC pipes SDR 11.5 & Plain CPVC SDR 11.5 fittings fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge. |
| 21 | S&F in-repair of 20mm dia (Outer) CPVC female brass treaded adaptor of SDR 11.5 fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge. |
| 22 | S&F in-repair of 25mm dia (Outer) CPVC female brass treaded adaptor of SDR 11.5 fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge. |
| 23 | S&F in-repair of 20mm dia (Outer) CPVC brass treaded elbow of SDR 11.5 fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge. |
| 24 | S&F in-repair of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by Engineer-in-charge. |
| 25 | S&F in-repair of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by Engineer-in-charge. |
| 26 | S&F in-repair of 110mm dia PVC (SWR) bends any radius with access door, complete all as specified and as directed by Engineer-in-charge. |
| 27 | S&F in-repair of 75mm dia PVC (SWR) bends any radius with access door, complete all as specified and as directed by Engineer-in-charge. |
| 28 | S&F in-repair of 110mm dia PVC (SWR) junction single (single T) equal or unequal with access door, complete all as specified and as directed by Engineer-in-charge. |
| 29 | S&F in-repair of 75mm dia PVC (SWR) junction single (single T) equal or unequal with access door, complete all as specified and as directed by Engineer-in-charge. |
| 30 | S&F in-repair of 125/110mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-in-charge. |
| 31 | M&L for providing 150mm thick cement concrete 1:3:6, type C-2 (40mm graded aggregates) bed to 200mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed by Engineer-in-charge. |
| 32 | All as per Item No. 31 here-in-above, but for 100mm thick bed for 150mm dia drain pipes, complete all as specified and as directed by Engineer-in-charge. |
| 33 | M&L for providing 200mm dia Salt-glazed stoneware drain pipes laid in trenches and jointed including demolition of existing old damaged pipes, complete all as specified and as directed by Engineer-in-charge. |
| 34 | All as per Item No. 33 here-in-above, but for 150mm dia Salt-glazed stoneware drain pipes, complete all as specified and as directed by Engineer-in-charge. |
| 35 | S&F in-repair of 150 mm internal diameter of double wall corrugated (DWC) high density polyethelene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 part-2 complete all as per specified and as directed by Engineer-in-charge. MAKE- Sintex/ Supreme/ Astral |
| 36 | S&F in-repair of 100 mm internal diameter of double wall corrugated (DWC) high density polyethelene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 part-2 complete all as per specified and as directed by Engineer-in-charge. MAKE- Sintex/ Supreme/ Astral |
| 37 | Cleaning of air/ dust blockage from internal external water supply (surface/ concealed) pipe line from OH service tank of any type by taking out pipe and pipe fittings (as required) and removing air, scales, dirts, etc. and re-fixing all pipe and fittings as existing to facilitate smooth supply of water, complete all as per specified and as directed by Engineer-in-charge. |
| 38 | M&L for cleaning of chocked/ blocked IWC/ EWC/ Nahani/ Floor/ Gully traps of any description and in any position as per user requirement including washing/cleaning upto Ist manhole complete all as specified and as directed by Engineer-in-charge. |
| 39 | M&L for Cleaning of sewage line of any diameter and of any description including manholes by manually or other means, to clear the sludge/blockage inside the sewage line and manholes and will be flushing with water to drain out sludge etc. inside the sewage line from manhole to ease the flow of sewage including removing the sludge upto a distance of 250m and re-fixing the manhole cover complete all as specified and as directed by Engineer-in-charge. |
| 40 | M&L for taking out deposited sludge and water from septic tanks of any type and size by mechanical means using sewage pump with tanker (truck mounted honey sucker) and removing night soil/sludge out of MOD land including sweeping/cleaning with water and spreader bleaching powder, complete all as specified and directed by Engineer-in-charge. (Only sludge shall be measured). NOTE- Disposal of sludge at outside MoD land shall be at contractor's own arrangement. |
| 41 | All as per Item No. 40 here-in-above, but for cleaning of manhole/ covered drain of any size and depth, complete all as specified and as directed by Engineer-in-charge. |
| 42 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for pipe of internal dia. 150mm, complete all as specified and as directed by Engineer-in-Charge. |
| 43 | M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge. |
| 44 | M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge. |
| 45 | M&L for preparing old plastered or unplastered surfaces of wall and applying one coat of cement base paint of any shade, complete all as specified and as directed by Engineer-in-charge. |
| 46 | M&L for preparing old plastered or unplastered surfaces of wall and applying one coat of white wash, complete all as specified and as directed by Engineer-in-charge. |
| 47 | M&L for preparing old plastered or unplastered surfaces of wall and applying one coat of distemper oil emulsion of any shade, complete all as specified and as directed by Engineer-in-charge. |
| 48 | M&L for preparation of old painted steel/ iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of Synthetic enamel paint (1st quality) of any tint, complete all as specified and as directed by Engineer-in-charge. |
| 49 | M&L for preparation of old painted wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of Synthetic enamel paint (1st quality) of any tint, complete all as specified and as directed by Engineer-in-charge. |
| 50 | S&F in-repair of Vitreous China Urinal, Half stall type, white with and including grating, 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe and providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long CP brass screws, pointing around urinal back in putty; complete all as specified and as directed by Engineer-in-charge. |
| 51 | S&F in-repair of Vitreous China wash basin, white, with brackets, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand including 32mm dia CP Waste fittings, complete all as specified and as directed by Engineer-in-charge. |
| 52 | S&F in-repair of vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge. |
| 53 | S&F in-repair of Wash down water closet (Pedestal pattern) pan and S/P trap of 540x375x415mm with and including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or anodised aluminium hinging device including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge. |
| 54 | S&F in-repair of 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm dia, with and including making necessary connections, complete all as specified and as directed by Engineer-in-charge. |
| 55 | M&L for petty repair to high or low level flushing cistern of any capacity by adjusting the float valve, checking of PVC connection, PVC bend including replacing of rubber washer, check-nut, plunger, etc. of any type and cleaning the all scales, dirts formed inside, complete all as specified and as directed by Engineer-in-charge. |
| 56 | S&F in-repair of 15 mm dia fancy type Brass CP telephonic wall mixer (3-in-1) for mixing hot & cold water, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |