| 1 | Taking down carefully aluminium / copper point wiring (light, fan, socket, power point) including batten, conduit, casing caping and fittings to match with existing surface complete removing from site, making good disturbed surfaces of wall, floor, ceiling complete all as specified and directed. |
| 2 | Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 3 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 4 | Taking down carefully ceiling/ exhaust fans, sealing cable ends, dismantelling blades removing fan and blades for taking to store and refixing back to its original position and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 5 | M&L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLSH Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLSH type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC casing capping, medium grade of suitable size including all fittings such as bend, elbow, tee, joint etc with sunk cast pressed steel terminal box made out of MS sheet with 3 mm thick hylum laminated sheet cover / plastic gang box for mounting of switch, socket, fan regulator complete all as specified and directed for following:- |
| 6 | Light /bell point controlled by one number one way switch |
| 7 | Fan point controlled by one number one way switch |
| 8 | 5 Amp s socket point on same board |
| 9 | 5 Amp switch socket point on independent board |
| 10 | Light point controlled by one number Two way switch |
| 11 | All as per item Ser No 5.00 here in before but with 2.5 sqmm PVC insulated, unsheathed cable multistranded FRLSH type, copper conductor (for phase & neutral) and 2.5 sqmm (for earth wire with same specification) for 6/16 Amp switch socket point on independent board complete all as specified and directed. |
| 12 | All as per item Ser No 5.00 here in before but with 4.0 sqmm PVC insulated, unsheathed cable multistranded FRLSH type, copper conductor (for phase & neutral) and 4.0 sqmm (for earth wire with same specification) for 6/16 Amp switch socket point on independent board complete all as specified and directed. |
| 13 | M&L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLSH Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLSH type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC conduit, medium grade of suitable size including all fittings such as bend, elbow, tee, joint, junction box including cutting chases for concealed conduits/ sunken boxes and making good to disturbed walls,floors with sunk cast pressed steel terminal box made out of MS sheet for mounting of switch, socket, fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and directed for following:- |
| 14 | Light / bell point controlled by one number one way switch |
| 15 | Fan point controlled by one number one way switch |
| 16 | 5 Amp s socket point on same board |
| 17 | 5 Amp switch socket point on independent board |
| 18 | Light point controlled by one two way switch complete |
| 19 | All as per item Ser No 8.00 here in before but with 2.5 sqmm PVC insulated, unsheathed cable multistranded FRLSH type, copper conductor (for phase & neutral) and 2.5 sqmm (for earth wire with same specification) for 6/16 Amp switch socket point on independent board complete all as specified and directed. |
| 20 | All as per item Ser No 8.00 here in before but with 4.0 sqmm PVC insulated, unsheathed cable multistranded FRLSH type, copper conductor (for phase & neutral) and 4.0 sqmm (for earth wire with same specification) for 6/16 Amp switch socket point on independent board complete all as specified and directed. |
| 21 | M&L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLSH Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including ERW conduit, medium grade of suitable size including all fittings such as bend, elbow, tee, joint, junction box complete all as specified and directed. |
| 22 | M & L for point wiring with 4.0 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLSH Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 4.0 sqmm copper conductor, multistranded cable (FRLS type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including ERW conduit, medium grade of suitable size including all fittings such as bend, elbow, tee, joint, junction box complete all as specified and directed. |
| 23 | S&F in repair / replacement of submain wiring with 2 X 1.5 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade alongwith 1 X 1.5 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 24 | S&F in repair / replacement of submain wiring with 2 X 2.5 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade alongwith 1 X 2.5 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 25 | M&L for Concealed Sub main wiring with 2 X 6.0 sqmm PVC insulated unsheathed FLRS copper conductor single core multi stranded and one run of insulated copper earth wire 1 X 6.0 sqmm drawn through PVC medium grade Conduit complete all as specified and directed. Note :- Copper conductor 3 run of 6 sqmm and one run PVC conduit shall be measured as one length. |
| 26 | S&F in repair / replacement of submain wiring with 2 X 6.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade alongwith 1 X 6.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 27 | S&F in repair / replacement of submain wiring with 2 X 4.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade alongwith 1 X 4.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 28 | S&F in repair / replacement of submain wiring with 4 X 6.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade alongwith 1 X 6.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLSH type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 29 | S&F in repair / replacement of submain wiring with 4 X 10.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 10.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 30 | S&F for switch piano flush type 5/6 amps, 230 volt, one way, single pole complete all as specified and directed. |
| 31 | S&F for socket 5 pin, multipurpose type, 5 Amps, piano flush type, 230V complete all as specified and directed. |
| 32 | S&F for switch socket combination 2 in 1, 5 pin, multipurpose type, 5/6 Amps, piano flush type 230 V complete all as specified and directed. |
| 33 | S&F for switch socket combination 6 pin, multipurpose type, 15/16 Amps, piano flush type 230 V complete all as specified and directed. |
| 34 | S&F for bell push switch, piano flush type 5 amps, 240 volts, single pole complete all as specified and directed. |
| 35 | S&F for step type electronic fan regulator piano flush type, 230 Volts, 5 speed complete all as specified and directed. |
| 36 | S&F for electric buzzer / ding dong bell, AC, 230 volt single phase complete all as specified and directed. |
| 37 | S&F for ceiling rose 3 terminals / PVC / Polycarbonate, isolated body, surface type with ISI marked 230 V complete all as specified and directed. |
| 38 | S&F for lamp holder, PVC / polycarbonate type with back plate straight or angular, 230 volts suitable for batten fitting complete all as specified and directed. |
| 39 | S&F for switch 2 way 6 Amps,230 volts, 50 HZ complete all as specified and directed. |
| 40 | S&F in repair / replacement of switch piano flush type 5/6 amps, 230 volt, one way, single pole complete all as specified and directed. |
| 41 | S&F in repair / replacement switch 2 way 6 Amps,230 volts, 50 HZ complete all as specified and directed. |
| 42 | S&F in repair / replacement of socket 5 pin, multipurpose type, 5 Amps, piano flush type, 230V complete all as specified and directed. |
| 43 | S&F in repair / replacement of switch socket combination 2 in 1, 5 pin, multipurpose type, 5/6 Amps, piano flush type 230 V complete all as specified. |
| 44 | S&F in repair / replacement of switch socket combination 6 pin, multipurpose type, 15/16 Amps, piano flush type 230 V complete all as specified and directed. |
| 45 | S&F in repair / replacement of switch socket combination 5 pin, multipurpose type, 5/6 Amps with box piano flush type 230 V complete all as specified and directed. |
| 46 | S&F in repair / replacement of switch socket combination 6 pin, multipurpose type, 15/16 Amps with box, piano flush type 230 V complete all as specified and directed. |
| 47 | S&F in repair / replacement of bell push switch, piano flush type 5 amps, 240 volts, single pole complete all as specified and directed. |
| 48 | S&F in repair / replacement of step type electronic fan regulator piano flush type, 230 Volts, 5 speed complete all as specified and directed. |
| 49 | S&F in repair / replacement of step type deluxe electronic fan regulator flush type, 230 Volts, 5 speed complete all as specified and directed. |
| 50 | S&F in repair / replacement of electric buzzer / ding dong bell, AC, 230 volt single phase complete all as specified and directed. |
| 51 | S&F in repair / replacement of ceiling rose 3 terminals / PVC / Polycarbonate, isolated body, surface type with ISI marked 230 V complete all as specified and directed. |
| 52 | S&F in repair / replacement of lamp holder, PVC / polycarbonate type with back plate straight or angular, 230 volts suitable for batten fitting complete all as specified and directed. |
| 53 | S&F in repair / replacement of modular switch 1 way 10 Amps, 1 module, 230 volt complete all as specified and directed. |
| 54 | S&F in repair / replacement of modular switch 1 way 16 Amps, 1 module, 230 volt complete all as specified and directed. |
| 55 | S&F in repair / replacement of modular socket 1 way 6 Amps, 2/3 pin combined, 2 module, 230 volt complete all as specified and directed. |
| 56 | S&F in repair / replacement of modular socket 1 way 6/16 Amps, 3/3 pin combined, 2 module, 230 volt complete all as specified and directed. |
| 57 | S&F in repair / replacement of modular Bell Push Switch 10 Amps 1 module, 230 volt complete all as specified and directed. |
| 58 | S&F in repair / replacement of Modular type electronic fan regulator 2 module, 5 speed complete all as specified and directed. |
| 59 | S&F in repair / replacement of switch flame proof rotary type with termination box in LM6, 16A, single pole, 230V complete all as specified and directed. |
| 60 | S&F in repair / replacement of switch socket & plug combined in LM6 cable termination box in LM6, 25A, 2P+earth, 230V complete all as specified and directed. |
| 61 | S&F in repair of sheet metal enclosure, MCB DB, single door, single pole & neutral, 2 way, 230 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 62 | S&F in repair of sheet metal enclosure, MCB DB, double door, single pole & neutral, 4 way, 230 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 63 | S&F in repair of sheet metal enclosure, MCB DB, double door, single pole & neutral, 8 way, 230 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 64 | S&F in repair of sheet metal enclosure, MCB DB, double door, Triple pole & neutral, 4 way, 415 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 65 | S&F in repair of Sheet metal enclosure, MCCB DB, TP&N, vertical type, double door with bus bars, neutral links, blanking plates 4 way, 415 volts, 50 Hz suitable for mounting MCCB 4 pole, 100 Amps, 415 volts, 18 kA , fixed type as incomer complete all as specified and directed. |
| 66 | S&F in repair of sheet metal enclosure, single pole and neutral with two pin and earth plug and socket, 20 Amps, 230 volts, 50 Hz complete with one single pole MCB of 20 Amps, 10 kA, 230 volts, 50 Hz, C curve type complete all as specified and directed. |
| 67 | S&F in repairs MCB single pole, 6 to 32 Amps, 230 volts, 10 kA, C series complete all as specified and directed. |
| 68 | S&F in repairs MCB single pole and neutral, 32 Amps, 230 volts, 10 kA, C series complete all as specified and directed. |
| 69 | S&F in repairs MCB Triple pole and neutral, 40 to 63 Amps, 415 volts, 10 kA, C series complete all as specified and directed. |
| 70 | S&F in repairs MCCB Triple pole and neutral,100 Amps, 415 volts, 16 kA, fixed type complete all as specified and directed. |
| 71 | S&F in repairs MCCB Triple pole and neutral,125 Amps, 415 volts, 16 kA, fixed type complete all as specified and directed. |
| 72 | M&L for LED Bulb (B-22) of 1 x 9 w fitting properly in Lamp holder complete all as specified and directed. |
| 73 | S&F in repair of recessed mounted CIMFR certified LED 1 X 16/20 watt, 230 Volts, 50 Hz flameproof batten fitting suitable for and including single T8 tube of 16W/20W, recommended for Gas/Vapor group of llA & llB and zone 1& 2, IP 65 Protection including connection wire complete all as specified and directed. |
| 74 | S&F in repair of recessed mounted CIMFR certified LED 2 X 16/20 watt, 230 Volts, 50 Hz flameproof batten fitting suitable for and including double T8 tube of 16W/20W, recommended for Gas/Vapor group of llA & llB and zone 1& 2, IP 65 Protection including connection wire all as specified and directed |
| 75 | S&F in repairs of electrically operated Industrial gong bell made of stainless steel 230 volts AC, 50 Hz with existing size complete all as specified and directed. |
| 76 | S&F in repair of wall mounted endura linear, decorative ultra slim square profile LED 20 watt, 230 volts, 50 Hz lighting fixture with extruded polycarbonate lighting fixture, environmental friendly,energy efficient ready to use pack including lamp complete all as specified and directed. |
| 77 | S&F inverter type batten LED light fitting of capacity 1X 20 W (or nearest next higher wattage) (4feet), 6500K, wall/ surface mounted,square profile housing and polycarbonate channel including lithium lon battery with charging time 8 hours and back up time up to 4 hours decorative type with integrated high efficiency electronic driver and operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and directed. |
| 78 | S&F in repair of wall mounted endura linear, decorative ultra slim square profile LED 10 watt, 230 volts, 50 Hz lighting fixture with extruded polycarbonate lighting fixture, environmental friendly,energy efficient ready to use pack including lamp complete all as specified and directed. |
| 79 | S&F for Decorative wall light fixture made up of polycarbonate suitable for 09 Watt LED retrofit of type B-22 base, IP66 grade, with and including inverter type 09 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified. Make - Havells , CAT No - LHFOECE1TZ1B014. |
| 80 | S&F in repairs of LED retrofit tube 18/20 watt, 230 volts, 50 Hz, LED T8 tube with extruded Al body, PC diffuser and inbult driver, double sided connection complete all as specified and directed. |
| 81 | S&F in repairs of bulk head luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge -lit LED luminaire comprising of high brightness LEDs 10 watt, 230 volts, 50 Hz including lamp, connection wire complete all as specified and directed. |
| 82 | S&F in repairs of E26 seek plus down light 6 watt, 230 volts, 50 Hz, Round / Square recess mounted (white / warm white) suitable to fulfil ground requirements aesthetically designed aluminium die-cast enclosure, with separate replaceable constant current driver including lamp, connection wire complete all as specified and directed. |
| 83 | S&F in repairs of slim, compact, aluminium die cast edge lit panel, Round / Square recess mounted (white / warm white) suitable to fulfil ground requirements with opal diffuser and separate electronic driver 12 watt, 230 volts, 50 Hz including lamp, connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 84 | S&F in repair of slim, compact, aluminium die cast edge lit panel, Round / Square recess mounted (white / warm white) suitable to fulfil ground requirements with opal diffuser and separate electronic driver 15 watt, 230 volts, 50 Hz including lamp, connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 85 | S&F in repair of recessed mounted 36 watt (clear white) LED panel light 600 mm X 600 mm, ultra slim design, 230 volts, 50 Hz with CRCA sheet housing precoated white colour and high quality diffuser for uniform light and high efficiency with separate replaceable electronic driver including lamp connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 86 | S&F in repair 6 Sqmm twin core cable flat or circular stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed. |
| 87 | S&F in repair 10 Sqmm twin core cable flat or circular stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed. |
| 88 | Taking down and refixing after repairs ceiling fans of any make/model/sweep in its original position, connecting and testing, including provision of cable from ceiling rose/connector to fan complete all as specified and directed. |
| 89 | Taking down and refixing after repairs exhaust fans of any make/model/sweep in its original position, connecting and testing, including provision of cable from ceiling rose/ connector to fan complete all as specified and directed. |
| 90 | Taking down and refixing after repairs air circulator fans of any make / model /sweep in its original position, connecting and testing complete all as specified and directed.Note for Item Nos. 76 to 78 :- Bearing / gun metal bush / rubber bush & bolts / capacitor / rewinding / shaft etc. will be measured and paid separately. |
| 91 | S&F in repair converter circuit converts mains AC(90 V-285 V) to DC(24 V) using a flyback,boost PFC or buck converter, Microcontroller Unit and MOSFET gate driver for BLDC fan of any existing make/ model/sweep complete all as specified and directed. |
| 92 | M&L for rewinding of ceiling fans 1200 /1400 mm sweep of any make/model, including removal of existing burnt windings completely and carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete including dismantling and re-assembling of starter, rotor, blades etc complete all as specified and directed. Note:- (Rate is inclusive of transportation to and fro from MES store/site to workshop in Tinsukia/ Dibrugarh). |
| 93 | All as per item No.82 above but PVC (square/Round) type exhaust fans up to 250 mm sweep complete all as specified and directed. |
| 94 | All as per item No.82 above but exhaust fans up to 300 mm sweep. |
| 95 | All as per item No.82 above but exhaust fans from 325 mm to 450 mm sweep. |
| 96 | All as per item No.82 above but air circulator fans up to 450 mm sweep. |
| 97 | M&L for cleaning / preparation of surfaces of ceiling fans up to 1400 mm sweep thoroughly and painting with one coat of spray painting (body and blades both) using synthetic enamel white paint over the existing paint and stenciling of MES No. with black paint over it complete all as specified and directed.Note:- (Rate is inclusive of filling of cavities with filler and matching to existing finishing of fans) |
| 98 | All as per item No.87 above but exhaust fans up to 300 mm sweep complete all as specified and directed. |
| 99 | All as per item No.85 above but exhaust fans from 325 mm to 450 mm sweep complete all as specified and directed. |
| 100 | All as per item No.85 above but air circulator fans up to 450 mm sweep complete all as specified and directed. |
| 101 | S&F in repair of ball bearings, bearing No.6201 suitable for ceiling fans/wall mounted fans /exhaust fans /air circulator fans /table fans of any make/model/sweep complete all as specified and directed. |
| 102 | All as per item No. 91 above but bearing No.6202. |
| 103 | All as per item No. 91 above but bearing No.6203. |
| 104 | All as per item No. 91 above but bearing No.6204. |
| 105 | All as per item No. 91 above but bearing No.6205 |
| 106 | S&F in repair Oil type capacitor of 2.5 Mfd suitable for ceiling fans / wall mounted fans /exhaust fans /air circulator fans /table fans complete all as specified and directed. |
| 107 | All as per item No. 96 above but 4.0 Mfd complete all as specified and directed. |
| 108 | S&F in repair box type heavy duty Polypropylene Film capacitor of capacity upto 2.5 Mfd suitable for PVC type exhaust fans complete all as specified and directed. |
| 109 | S&F in repair gun metal bush suitable for ceiling fans/ wall mounted fans /exhaust fans/ air circulator fans/ table fans of any make/ model/ sweep complete all as specified and directed. |
| 110 | S&F in repair rubber bush with bolt and nut suitable for ceiling fans /wall mounted fans /exhaust fans /air circulator fans /table fans of any make/model/sweep complete all as specified and directed. |
| 111 | S&F in repair split pin and jam nut suitable for ceiling fans/ wall mounted fans/ exhaust fans/ air circulator fans /table fans of any make/model/sweep complete all as specified and directed. |
| 112 | S&F in repair MS down rod 15 mm bore and 450 mm long including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 113 | S&F in repair shaft suitable for ceiling fans /exhaust fans /air circulator fans of any make/model and sweep with necessary machining work complete all as specified and directed. |
| 114 | S&F in repair the canopy suitable for ceiling fan of existing type & size complete all as specified and directed. |
| 115 | S&F in repair MS clamp made of flat iron size 25 X 6 mm including nuts, bolts and 'S' hook complete all as specified and directed. |
| 116 | M&L for tubes 'medium grade' galavanised iron pipe of size 50 mm bore in short lenghts, with all fittings and fixed complete between walls for hanging of ceilings fans etc including cutting into sizes as per site requirement after taking down old unserviceable one complete all as specified and directed. |
| 117 | S&F in repairs of exhaust fan louvers iron shutter suitable for exhaust fan upto 300 mm sweep,necessary mounting arrangement with the help of flare nut of suitable size including taking down old unserviceable one complete all as specified and directed. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information |