| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposalof unserviceable materials with all leads all complete as per direction of E/I |
| 2 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 3 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 4 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm.Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stonechips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 5 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 6 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 7 | Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 |
| 8 | Providing and laying APP (Atactic polypropylene polymer) modified refabricated five layer 3mm thick water proofing membrane, black finished reinforced with non - woven polyester matt consisting of acoat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87- 0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all jointsetc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under :Jointstrength in longitunal and transverse direction at 23°c as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane mot less than 150°C. Coldflexibility shall be upto - 2°C When tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through theauthorised applicator of the manufacturer of membrane :3mm thick. ITEM 14.90 DSR |
| 9 | Providing TMT steel reinforcement as per approved design and drawing excluding carriage of M.S bar to work site, all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.5.5 A |
| 10 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.BCD 5.10.10 |
| 11 | Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size. |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.D.S.R. Item No. 13.80 |
| 13 | Finishing wall with textured exterior paint of required shade New work ( Two or more coats applied @ 3.28ltr/10sqm) over and including primer coat of exterior primer applied @ 2.2./10sqm DSR item no.13.45.1 |
| 14 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty where required, scaffolding, washing of floors and taxes all complete as per specification and direction of E/I.B.C.D. S.O.R. Item No. 5.8.18 |
| 15 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).D.S.R. Item No. 13.47.1 |
| 16 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification.B.C.D. S.O.R. Item No. 5.8.41 |
| 17 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.8.43 |
| 18 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.B.C.D. S.O.R. Item No. 5.3.8 |
| 19 | S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.) |
| 20 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes.D.S.R. Item No. 12.41.2 |
| 21 | Earthwork in excavation in foundation Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth a obtained to a distance Up to 50M including all lifts with leveling remming the foundation trenches removing roots of trees shurbsall complete as per approved design, building specification and direction of E/I |
| 22 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item -A) |
| 23 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fullycompacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M andlift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compactedvolume) |
| 24 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 25 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I. |
| 26 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:2:4 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 40 mm nominal size) |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 28 | Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centering, shuttering, finishing and reinforcement- all work up to plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand (zone-iii): 3 graded stone aggregate 20 mm nominal size). |
| 29 | Reinforced cement concrete work in walls (any thickness), including attached plasters, buttresses, plinth and string courses, fillets, column pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand (zone -iii):3 graded stone aggregate 20 mm nominal size) |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, piers, Abutments, posts and Struts. |
| 32 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand ofF.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mmdepth curing, taxes and royalty all complete as per building specification and direction of E/I |
| 33 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 34 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 35 | Providing Tor steel reinforcement of 8mm 12 to 16 mm dia. M.S. bars as per approved design and drawing including carriage of M.S. bars to work site cutting, bending and binding with annealed wire cost of wire,removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 36 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 37 | Providing and laying vitrified floor tiles for step of stair in with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete step tiles & have bullnose, Anti and self embossed line. Size of Tile 1200x300mmx15 mm |
| 38 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 39 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 40 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed PVC conduit, with modular switch, modular plate suitable GI box and the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc. as required.(GROUP-A) |
| 41 | wiring for ligh/power plug with 2x4 sq.mm FR PVC insulated,copper conductor,single core cable in and surface/recessed PVC conduitalong with 1 no. 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 42 | Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor single core cable in and surface/recessedPVC coduit as required.2x1.5sqmm+1x1.5sq mm earth wire |
| 43 | 2x2.5sqmm+1x2.5sq mm earth wire |
| 44 | 2x6 sqmm+1x6 sq mm earth wire |
| 45 | S/F 3 pin.5amp. Ceilling rose on the existing junction box/wooden block including connection etc.as reqd. |
| 46 | S/F brass battan/angle holder including connection etc.as reqd. |
| 47 | S/F of following sizes of PVC conduit alongwith the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required . 20 mm PVC coduit. |
| 48 | 25 mm PVC coduit. |
| 49 | Suppling and fixing following piano type switch / socket on the existing switch box / cover including connection etc. as reqd.5/6 amps switch |
| 50 | 5/6 amps socket outlet |
| 51 | S/F PVC/GI box of following sizes on surface or in recesses with suitable size of phenolic laminated sheet cover infront including painting etc.210 mm x 206 mm x48 mm deep(10\\"x12\\") |
| 52 | Supplying and fixing of following way single pole & neutral, sheet steel , MCB distribution board 240 volts, on surface /recess , complete with tinned copper bushbars ,neutral busbar, earth bar , din bar ,detachable gland plate , interconnections ,phosphatized and powder painted including earthing etc. as requried. (but without MCB/RCCB/ISOLATOR) (2+8 way double door) |
| 53 | 48\\"(1200mm) ceiling fan |
| 54 | Fan regulator |
| 55 | 9/10 watts led bulb |
| 56 | 10/12 watts tubelight fitting(led) |
| 57 | For wall painting and writing |
| 58 | Carriage of materialsBricks |
| 59 | Stone chips |
| 60 | Cement |
| 61 | steel |
| 62 | Add 18% G.S.T |
| 63 | Add 1% L.C Please Enable Macros to View BoQ information |