| 1 | Earthwork in excavation of foundation trenches in ordinary in soil (vide classification od soil item -A) and disposal of excavated earth as obtained to a distance upto 50M including all lift, leveling ramming the foundation trenches, removing roots of tree shurbs all complete as per approved design, building specification and direction of E/I. (5.1.1.) |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) (5.1.2.) |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). (5.1.7) |
| 4 | Providing coarse clean sand filling in foundation trenches and plinth including ramming and watering in layers not exceeding 150mm thick with all leads & lifts including the cost of all materials, labour, royality, & taxes all complete as per building specification and direction of E/I (5.1.10) |
| 5 | Providing designation 75B one brick flat soling joints filled with local sand including the cost of watering taxes royality all complete as per building specification and direction of E/I. (5.6.3) |
| 6 | Providing and laying factory made chamfered edge Cement concrete paver blocks in footpath, parks, lawns,drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer- in-charge. D.S.R 16.91.2 80 mm thick C.C. Paver block of M-30 grade with approved color design and pattern. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:2:4 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 20 mm nominal size) (5.3.1.2) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (5.3.1.1.) |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (5.3.9.1.) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) (5.3.10.) |
| 11 | Providing designation 75B brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. (5.2.3.) |
| 12 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). (5.3.5.) |
| 13 | Providing designation 75B brick in C.M. (1:6) in Superstructure with approved quality of clean sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints , cost of screening materials raking out joints to 15 mm depth , curing , taxes and royality all complete as per building specification and direction of E/I (5.2.14.) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (5.3.11.) |
| 15 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.1) |
| 16 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.2) |
| 17 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.3.) |
| 18 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.5.) |
| 19 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.6.) |
| 20 | Providing and fixing aluminium work for doors, windaws, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including neccessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc - do- of E/I. (D.S.R 21.1.1.1) |
| 21 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P. brass/stainless steel screws etc. - do- of E/I. (D.S.R 21.2.1) |
| 22 | Providing and fixing glazing in aluminium door, window, ventilator shutter and partitions etc. with required EPDM rubber/neoprene gasket etc - do- of E/I. (D.S.R 21.1.1.1)with required EPDM rubber/neoprene gasket etc - do- of E/I. (D.S.R 21.3.2) |
| 23 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty: surkhi: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (5.6.19) |
| 24 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (5.5.12.) |
| 25 | Supplying, fitting, and fixing M.S. Grill gate with M.S. grill made of 20X6mm M.S. Flate or 16mm M.S. angle frame of size 60x60x6mm, including cost of fabricated approved neccessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all com. as per specification and direction of E/I. (5.5.30.) |
| 26 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. (5.6.7.) |
| 27 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.14.) |
| 28 | Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.15.) |
| 29 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (5.5.13.) |
| 30 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) (5.8.41.) |
| 31 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (5.8.45.) |
| 32 | Providing two coats of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface thooughly cost of scaffolding and taxes all complet as per building specification and direction of E/I. (5.8.43) |
| 33 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.6.) |
| 34 | Providing 12 mm thick cement plaster in C.M. (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all lead and lift of water , scaffolding taxes and royality all complete as per buildig specification and direction of E/I (5.7.3 ) |
| 35 | Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I. (5.8.18) |
| 36 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. do all complete job as per direction of EI (DSR 13.26) |
| 37 | Finishing walls with Premium Acrylic Smooth exterior paint with of required shade: Old work(Two or more coats applied @ 1.67 ltr/ 10 sqm) over and including priming coat exterior primer applied @ 2.20kg/10sqm. (D.S.R 13.46.1) |
| 38 | Finishing walls with Premium Acrylic Smooth exterior paint with of required shade: Old work(Two or more coats applied @ 1.43 ltr/ 10 sqm) over and including priming coat exterior primer applied @ 2.20kg/10sqm. (D.S.R 13.47.1) |
| 39 | Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standard rolled 'Z' and mullion stees sections and size as per IS - 1038 joints met and welded with 100x 16x 3mm, M.S lugs fixed in cement concrete (1:2:4) blocks 15x 10x 10cm, size including cost of oxidised iron fittings, with hinges, handle per steps,catch springs, 3mm thick plain glass panes with Aluminimum beads and 95 inner frame fixed with lugs with 20mm lond 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I. (5.5.18) |
| 40 | Providing Tor steel reinforcement of 8, 10 mm and 12 mmmm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.5) (a) |
| 41 | Providing Tor steel reinforcement of 8, 10 mm and 12 mm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.5) (b) |
| 42 | Providing Tor steel reinforcement of 8, 10 mm and 16 mm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.5) (c) |
| 43 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (5.3.8.) |
| 44 | Point wiring in PVC conduit with Modular type switch wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5 sqmm FRPVC insulated copper conductor single core cable in surfface/ recessed PVC conduit with modular type switch modular plate suitable of GI box etc as required (1.1.1) EnergyGroup -(C) |
| 45 | Power plug widng in PVC conduit (2 x 4 sq. nun) : Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loop carthing etc as required. (1.5.)Energy |
| 46 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (1.21) Energy20 mm. P.V.C. Conduit. |
| 47 | 25 mm. P.V.C. Conduit |
| 48 | Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required (1.7)2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (1.7.2) |
| 49 | 2 x 4 sq.mm + 1 x 4 sq.mm earth wire (1.7.3) |
| 50 | S/F SP MCB DB Supplying and fixing following way three pole and neutral sheet MCB distribution board 415 volts on surface/recess complete with tinned copper busbar neutral busbar earth bar din bar detachable gland plate, interconnection phosphatized and powder painted including earthing etc as required (but without MCB/RCCB/Isolator) (2.10)4 way (8+12) Single door vertical type |
| 51 | Supplying and fixing suitable sizes G.I/PVC box on surface or inrecess with phenolic laminated sheet cover in frong including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps paino type switch connection painting etc as required. (1.29) |
| 52 | Supplying and Fixing Batten holder: Supplying and fixing Batten/Angle holder including connection etc as required.(1.34) |
| 53 | Supply, fitting and fixing of Special type bulk head fittings complete set with 9/10 Watt CFL/ LED. Make:- Havells/ Wipro/Baja. (M-869) |
| 54 | S/F ceiling rose : lsupplying and fxing 2 pn 5 amp. Ceiling rose on the existing junction box/ l*oo\\"n block including connection etc. as required. (1.33.) |
| 55 | Supplying installation, testing and commissioning of following size ceiling fan 3 Blades conforming to IS : 374:2019 including wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230v 50hz, single phase supply etc complete as required. (9.4)Ceiling Fan 48\\" (1200mm) BLDC 5star (9.4.1) |
| 56 | L2 50/60W LED Flood light (9.2.2) |
| 57 | Supplying and fitting - 1x28 watt TS Tubelight (865) |
| 58 | Carraige of matterials :-Cement - |
| 59 | Steel - |
| 60 | Sand- |
| 61 | Brick- |
| 62 | Paver block |
| 63 | Stone chips - |
| 64 | Add 18% G.S.T |
| 65 | Add 1% Labour Cess Please Enable Macros to View BoQ information |