| 1 | Earthwork in excavation of foundation trenches in ordinary in soil (vide classification od soil item -A) and disposal of excavated earth as obtained to a distance upto 50M including all lift, leveling ramming the foundation trenches, removing roots of tree shurbs all complete as per approved design, building specification and direction of E/I. (5.1.1.) |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) (5.1.2.) |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). (5.1.7) |
| 4 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). (5.1.8) |
| 5 | Providing coarse clean sand filling in foundation trenches and plinth including ramming and watering in layers not exceeding 150mm thick with all leads & lifts including the cost of all materials, labour, royality, & taxes all complete as per building specification and direction of E/I (5.1.10) |
| 6 | Supplying and (Properly as per design and drawing) rip- rap with good quality of boulders duly packed including the cost of materials, royalty all taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/I. (W.R.D 5.6.8) |
| 7 | Providing designation 75B one brick flat soling joints filled with local sand including the cost of watering taxes royality all complete as per building specification and direction of E/I. (5.6.3) |
| 8 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.(5.6.1) |
| 9 | Providing 150mm. Thick dry rammed khoa beaten to 112mm. (Compacted with water) made of well burnt or jhama bricks including ramming properly till Compacted thickness is achieved curing - do - of E/I. (5.6.5) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:2:4 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 20 mm nominal size) (5.3.1.2) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (5.3.9.1.) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) (5.3.10.) |
| 13 | Providing And laying in position cement concrete of specified grade excluding the coast of centering and shuttring -All work up to plinth level .1:1.5:3 (1 cement :1.5 coarse sand(Zone-III):3 graded stone aggregate 20mm nominal size) (5.3.1.1) |
| 14 | Providing designation 75B brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. (5.2.6.) |
| 15 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). (5.3.5.) |
| 16 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894 -1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.(5.2.52) |
| 17 | Providing designation 75 A brick work in C.M. (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.(5.2.2) |
| 18 | Providing designation 75B brick in C.M. (1:6) in Superstructure with approved quality of clean sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints , cost of screening materials raking out joints to 15 mm depth , curing , taxes and royality all complete as per building specification and direction of E/I (5.2.14.) |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (5.3.11.) |
| 20 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.1) |
| 21 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.3.) |
| 22 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.5.) |
| 23 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.6.) |
| 24 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (5.5.12.) |
| 25 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (5.5.29.) |
| 26 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. (5.6.7.) |
| 27 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.14.) |
| 28 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.(5.7.15) |
| 29 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l.(5.7.11) |
| 30 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) (5.8.41.) |
| 31 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (5.8.45.) |
| 32 | Supplying, fitting, and fixing M.S. Grill gate with M.S. grill made of 20X6mm M.S. Flate or 16mm M.S. angle frame of size 60x60x6mm, including cost of fabricated approved neccessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all com. as per specification and direction of E/I. (5.5.30.) |
| 33 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.6.) |
| 34 | Providing 12 mm thick cement plaster in C.M. (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all lead and lift of water , scaffolding taxes and royality all complete as per buildig specification and direction of E/I (5.7.3 ) |
| 35 | Providing 12 mm thick cement plaster in C.M. (1:3.) with clean coarse sand of F.M 1.5 including screening, curing with all lead and lift of water , scaffolding taxes and royality all complete as per buildig specification and direction of E/I (5.6.10.) |
| 36 | Providing two coats of snowcem shade and make over a coat of cement of primer on new surface including preparing the plastered surface smooth with sand paper, soaping, curing and taxes all complete as per building specification and direction of E/I. (5.8.24) |
| 37 | Supplying fitting and fixing C.A.R.W.D. pipe with necessary strip spikes bends shoes etc. including cost - do - of E/I. |
| 38 | Finishing walls with Premium Acrylic Smooth exterior paint with of required shade: Old work(Two or more coats applied @ 1.67 ltr/ 10 sqm) over and including priming coat exterior primer applied @ 2.20kg/10sqm. (D.S.R 13.46.1) |
| 39 | Providing Tor steel reinforcement of 8mm, 10 mm and 12 mmmm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.4) |
| 40 | Providing Tor steel reinforcement of 8, 10 mm and 12 mm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.5) (b) |
| 41 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standarddesign :(DSR 19.15.1)With 20x20 mm Square Bar |
| 42 | Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :(DSR 19.34.2)150 mm Dia |
| 43 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation and refilling all complete as per specification and direction of E/l.(3.3.8 corr) |
| 44 | Iron steel and material (sail/tiscon ) ex - bokaro rates excluding G.S.T angle size in mm (M-195(b) (i) |
| 45 | Labour for fabricating, erecting, hoisting and fixing in position structure steel work - do - of E/I. (5.5.28) |
| 46 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR 16.53) |
| 47 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (5.3.8.) |
| 48 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. (5.10.35.) |
| 49 | Supplying & Fixing C.I. Cover without frame -do-do- all complete job (DSR 19.18.1) |
| 50 | Point wiring in PVC conduit with Modular type switch wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5 sqmm FRPVC insulated copper conductor single core cable in surfface/ recessed PVC conduit with modular type switch modular plate suitable of GI box etc as required (1.1.2) EnergyGroup -(B) |
| 51 | Power plug widng in PVC conduit (2 x 4 sq. nun) : Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loop carthing etc as required. (1.5.)Energy |
| 52 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (1.21) Energy20 mm. P.V.C. Conduit. |
| 53 | 25 mm. P.V.C. Conduit |
| 54 | S/F Piaoo type switch/ socket : lSupptyrng and fxing of following piano type switch / socket on the existing lswitch box / cover including connections etc. as requted.1.23.5/6 amps, one way switch |
| 55 | 5/6 amps, one way switch |
| 56 | S/F PVC/G.I. boxes : Supplying and fixing of following sizes of PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1.22.7126 mm x277mmx 6lmm deep/ (6\\" x 12\\") |
| 57 | SIF S.P. MCB DB : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.8. 8 way double door |
| 58 | Supplying and Fixing Batten holder: Supplying and fixing Batten/Angle holder including connection etc as required.(1.34) |
| 59 | Supplying of 12\\" (300mm.) metel exhaust fan (M- 775) |
| 60 | Holder type CFL 15/16 watt LED Bulb (M-856) |
| 61 | Water supplyProviding and fixing Gum metal full way valve of approved quality, all complete, as per specification and direction of E/I. (3.1.12)i) 20 mm dia |
| 62 | ii) 25 mm dia |
| 63 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. (e) R.C.C. CHAJJA (3.1.18)250mm. Thick wall |
| 64 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.(3.1.21)C.P. Brass tower rail (C (i)) |
| 65 | C.P. Brass Soap container medium quality with screw & hinge etc. tower (C (ii)) |
| 66 | Approved basic rates construction material for preparations of schedule of rates only (material should confirm be relevent B.I.S specification) the rates (M-961)Pillar cock |
| 67 | Bib cock |
| 68 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR 12.41)Single socket pipe110 mm diameter (12.41.2) |
| 69 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion (DSR 12.42)Single \\"T\\" without door (75x75x75)mm (12.42.4.1) |
| 70 | Single \\"T\\" without door (110 x 110 x 110)mm (12.42.3.2) |
| 71 | 75mm Bend (12.42.5.1) |
| 72 | 110mm Bend (12.42.5.2) |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. D.S.R 18.725 mm nominal dia Pipes (18.7.3) |
| 74 | 32 mm nominal dia Pipes (18.7.4) |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.(D.S.R 18.8)15 mm nominal outer dia Pipes (18.8.1) |
| 76 | 20 mm nominal outer dia Pipes (18.8.2) |
| 77 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. (18.48) |
| 78 | Supply of G.l. pipes of Tata or any equivalent) as per IS-1239 all complete liob as per direction of E/I. (M-930 k)(i) 15mm dia |
| 79 | (ii) 20mm dia |
| 80 | (iii) 25mm dia |
| 81 | (iV) 32mm dia |
| 82 | (V) 40mm dia |
| 83 | Providing and fixing male ended 15mm dia brass bib cock all complete las per direction of E/I. (3.1.5.1) |
| 84 | Providing and fixing brass/C.I. stop lcock of approved quality allcomplete as per specification and direction of E/1. (A)BRASS STOP COCK(a) 15mm dia |
| 85 | Supplying fitting and fixing of G.I. fitting ............. all. Complete as per direction of E/I. (3.1.13)(A) Elbows.(a) 15mm dia |
| 86 | (b) 20mm dia |
| 87 | (c) 25mm dia |
| 88 | (d) 32mm dia |
| 89 | (b) Tee Plain.(a) 15mm dia |
| 90 | (b) 20mm dia |
| 91 | (c) 25mm dia |
| 92 | (d) 32mm dia |
| 93 | (c) Reducing Socket(b) 20mm dia |
| 94 | (c) 25mm dia |
| 95 | (d) 32mm dia |
| 96 | (d) Nipple.(b) 20mm dia |
| 97 | (c) 25mm dia |
| 98 | (d) 32mm dia |
| 99 | (e) Plugs.(a) 15mm dia |
| 100 | (b) 20mm dia |
| 101 | (c) 25mm dia |
| 102 | (d) 32mm dia |
| 103 | (f) Reducing Tee plain.(c) 25mm dia |
| 104 | (g) Union socket(a) 15mm dia |
| 105 | (b) 20mm dia |
| 106 | (c) 25mm dia |
| 107 | (h) Socket plain.(a) 15mm dia |
| 108 | (b) 20mm dia |
| 109 | (c) 25mm dia |
| 110 | (d) 32mm dia |
| 111 | cutting chnia or cornce for laving G ppes and restoring the same wit RCC(1:2:4) brick work in cement mortar (1:4) and cement Plaster (1:4 Taas per specification and direction of E/I. (3.1.17) |
| 112 | Making holes in walls for laving G.I. pipes and restorng the same after pipe llaving as per specification and direction of E/I. (3.1.18)(a) 125mm thick wall |
| 113 | Supplying fitting and fixing viterous white Rlazed earth ware I.W.C of parry Hindustan or any other I.S.S. approved makewith 100mm H.C.I.P Itrap15 litress. I. orcopull andlet go fushingdodo-all complete las per direction of E/I. (3.2.1)(A) 580mm long width 12.5 liters low C12.5 lit low level P.V.C. cisterns |
| 114 | Supplying & installation of PVC water Istorage tank (over complete (PPVC Tank as per IS specification) (D.S.R 18.48) |
| 115 | Supplying fitting and fixing viterious white glazed earthan ware wash hand basin of parry or Hindustan or any lother I.S.S. aproved make supported ondo. all complete as per Idirection of E/I. (3.2.5) |
| 116 | Making Sonk-pit 2.5 m duameter 3.0 meter deep with 45 x 45 cm dry brck honey comb shaft with brick and S.W drain pipe 100 with comman burnt clay FPS (non modular) brck of class ldesignation 7.5 each all complete job. |
| 117 | Carraige of matterials :-Cement - |
| 118 | Steel - |
| 119 | Sand- |
| 120 | Brick- |
| 121 | Fly Ash Brick |
| 122 | Local Sand |
| 123 | Boulder |
| 124 | Stone Metal |
| 125 | Stone chips - |
| 126 | Add 18%GST |
| 127 | Add Labour cess@ 1% Please Enable Macros to View BoQ information |