| 1 | Supply and fixing of 25 Mtr High Mast pole of approved make with rising system dip galvanized inside and outside dip. having pole sheet thickness 4 mm. top dia minimum 150 mm and bottom dia minimum 460 mm & base plate 32 mm thick) suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 12 luminaries & its control gear boxes 1.5 H.P. power tool motor, 3 point suspension system with steel wire rope 8 mm dia, double drum winch. including making suitable foundation as per manufacturer drawing/ site requirement along with foundation bolts, nuts, washers, anchor plates etc complete in all respect. SOR 21.3.3 |
| 2 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on 750 mm below the ground. (i) 16sq.mm 4 core SOR 20.1/20.1.9 |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire DSR 1.14.9 |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire DSR 1.14.10 |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in Existing surface/ recessed medium class PVC/Steel conduit as required. 3X 2.5sq.mm DSR 1.17.12 |
| 6 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB /Isolator). 4 way (4 + 12), Double door DSR 2.4.1 |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2.10.1 |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2.10.5 |
| 9 | Supplying, Installation, Testing & Commissioningof 200 Watt Flood Light, (System lumen efficacy ≥120 and <135 lm/Watt). powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5. with 5 Year OEM warranty. DSR 8.16.5 |
| 10 | Earthing with G.I. earth Pipe 4.5 Meter Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DSR 5.2 |
| 11 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15 |
| 12 | Supply and Laying of 63 mm dia DWC HDPE Pipe ISI marked along with all accessoriees like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench complete as required DSR 15.15.1 |
| 13 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4X16 Sqmm DSR 11.1.33 Please Enable Macros to View BoQ information |