| 1 | Supply&errection of Steel-tubular pole 410 SP-56,11 mtr. long 241 Kg. complete with 1/6 th of over all length of pole in cement concrete with one feet square/one feet dia cement ,concrete plinth around the pole above ground level. The foundations of underground will be of cement concrete in the ratio 1:2:4 .The stone ballast/brick-ballast used will be 1.25 cm (1/2x1) size with the stone pad 30x30x7.5 cm at the base, with MS pole Cap including all T&P, men & material for proper completion of work as per direction of Engineer in charge rate as per SIDC Sch. 02.07 |
| 2 | Supply/Fixing 11 KV ordinary pole fittings inculding all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. 03(a) |
| 3 | Supply & fixxing of 11 KV Originating/terminating pole fittings including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. 03.02(v) |
| 4 | Supply & fixxing of 11KV single/Section pole fittings including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. 03(d) |
| 5 | Supply & fixxing of 11 KV T-off pole fittings including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. 03(c) |
| 6 | Supply & fixxing of straight M.S channel of 75x40 mm, 2.24 Mtr.long including cost of holding clamps and materials for proper completion of work as per direction of Engineer in charge as per SIDC Sch. 03.03 |
| 7 | Supply & fixxing of 11 KV pin with insulator on channel & cross arm fixed on ST pole including cost of nuts,bolts,washers,T&P men & material for proper completion of work as per direction of Engineer in charge rate as per SIDC Sch. 03.07 |
| 8 | Supply & fixxing of 11 KV disc fittings for proper completion of work as per direction of Engineer in charge rate as per SIDC Sch. 03.08 |
| 9 | Supply&errection of double pole structure 410 SP-56,11 mtr. Long ST Pole complete with 1/6 th of over all length of pole in cement concrete with one feet square/one feet dia cement ,concrete plinth around the pole above ground level .The foundations of underground will be of cement concrete in the ratio 1:2:4 .The stone ballast/brick-ballast used will be 1.25 cm (1/2x1) size with the stone pad 30x30x7.5 cm at the base, including all T&P, men & material for proper completion of work rate as per SIDC Sch. 04(a) |
| 10 | Supply&errection of Stay set of HT Line for ST pole with GI anchor plate(152x152x6mm) stay rod (16mm dia x 1.85 mtr.long) GI stay below (16 mm dia, thimble,double stay, tightener ,stay insulator ,clamps & stay wire (GS 7/13 .15 mm) including grouting in 1:4:8 ratio of cement concrete using course sand ,over brunt brick ballast. including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 06(a) |
| 11 | Supply&errection of Stay of Gaurding channel for ST Pole with G.I Anchor plate (152x152x6mm) stay rod (16mm dia x 1.85 mtr.long) GI stay below (16 mm dia, thimble, double stay tightener, stay insulator, clamps & stay wire (GS 7/13 .15 mm) including grouting in 1:4:8 ratio of cement concrete using course sand, over brunt brick ballast. including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 06(b) |
| 12 | Supply,sagging,tensioning,jointing and binding of ACSR Dog conductor including cost of aluminium tape binding wire and jointing sleeves etc. complete in all respects including men & material,T&P proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 10.04 |
| 13 | Supply,sagging,tensioning,jointing and binding of G.I Wire no. 6 SWG on ST Pole complete in all respects including men & material,T&P proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 11.01 |
| 14 | Supply,sagging,tensioning,jointing and binding two parallel length of G.I Wire no. 6 SWG wire along the span and G.I 6 SWG wire across the span each at an internal of 5 mtr. for cross lacing complete in all respects including men & material,T&P proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 12.01 |
| 15 | Supply & fixxing of anticlimbing device fabricated grom G.I flat of 25mmx6mm size in a sape of ring of the pole size, having G.I flat pointed fins of the length 225 mm in 8 nos. and also barbed wire in 200 mm length above the said ring including material for proper completion of work as per direction of Engineer in charge |
| 16 | Supply & fixing of D clamp of size 50x6 mm flat iron on ST poles with nuts,bolt and washers etc. complete in all respect as per UPPWD Sch. No. 623 |
| 17 | Supply & fixing of 100 x 110 mm shackle insulator 100 x 80 mm pin insulator including GI bolt spindle, nuts etc. as pre UPPWD Sch. No. 621 |
| 18 | Supply and fixing of danger board fabricated from 10 gauge M.S.sheet as per I.E.Rules.UPSIDC E27.01 |
| 19 | Painting of ST pole and all mountings on it with two coats of aluminium paints with an under coat of red oxide paint above 10 Mtr. support above the ground level as per direction of Engineer in-charge of work/site including T&P, men & material required for proper completion of work.UPSIDC Sch. No.20.(2) |
| 20 | S/L of 185 sq. mm 3 core cable standard aluminium conductor XLPE (cross linked polyethylene) insulated PVC bedded glavanised flat steel strip armoured cables confirming to IS 7098 (Part-II) with latest amendments, 11 KV grade at a depth of 900 mm below ground level. (When cable is passed through DWC/MS/GI pipe)The armouring of cable shall be properly connected with earth conductor by clamp etc.(Gloster/Havells/Grandlay/Polycab/KEI make) |
| 21 | S/F of outdoor/indoor type 11 KV jointing kit heat shrinkable type for 11 KV cable including cost of all material, labour, T&P etc. for proper completion of work. (Raychem, Denson/Birla /3M make) for 3x185 sq.mm cable. |
| 22 | Supply & fixing of 11 KV straight through jointing kit heat shrinkable type for 11 KV cable including cost of all material,labour, T&P etc. for proper completion of work (Raychem/Denson/Birla/3M make) for 3x185 sq.mm cable. |
| 23 | Supply & laying of 160 mm dia (OD-160 mm & ID-136 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc.confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect . |
| 24 | S/Laying of 200 mm dia MS pipe ISI marked 6 mm thick as per IS 2062 grade Fe-400 including welding etc.complete laying with Bogi method, cost of all T&P men & material for proper completion of work complete in all respect. |
| 25 | Supply, erection, Installation, testing & commissioning of 100 KVA ,11/.433 KV 3 Phase ONAN core type aluminium wound outdoor type transfromer with voltage ratio between phase at no load as 11000/433 V arranged for Delta/Star connection as per vector group Dyn-11 with neutral brought out on L.V Side.The work including all standard fittings and accessories ,T&P men & material required for proper completion of work including first fillings of transformer oil etc. complete in all respect .The Transformer would confirm to approved GTP/Drawing/Technical specification and relevent IS required in UPPCL at the time of execution. The manufacturer of Transformer shall be in approved list of MVVNL rates taken as per Stock Issue rate sch. of UPPCL 2023-24 Sr No.71 |
| 26 | Supply & fixing of welded wire mesh fencing of 5x3x2.4 meter and 2x2.4 M gate including excavation base concrete & brick work with back filling etc. complete in all respect. |
| 27 | Making plinth for installation of transformer of size 1x1.5x1.10 M plinth complete with excavation base concrete with 1:4:8 (padding) first class brick work in ratio 1:3, CC work and plastering as per design.complete in all respect. |
| 28 | Supply & erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuse and instrument chamber etc. complete in all respects. (Incoming 200 Amp.,TPN-1 No.,Outgoing 100 Amp.TPN-2 Nos. as per UPPWD Sch. No. 802-a(ii) Cat. B Cubicle type as per approved make |
| 29 | S/B of 600x600x6mm G.I. plate vertically for earthing with its top at least 3 M. below ground level complete with 20 mm dia G.I.pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15 mm dia G.I.pipe up to switch board ( from appron to switch board the cost of G.I.pipe and G.I. wire be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcole /Coke and salt at least 150mm thick around etc. as per directions of E/I complete in all respect as per UPPWD Sch. No. 702 |
| 30 | S/F of 11 kV three phase D.O. fuse set complete with suitable clamps, nuts & bolts, fuse wire etc.as per Stock issue rate 2021-22 of UPPCL Sr no.93 |
| 31 | Supply & fixing of 100 mm dia G.I.pipes 'B' class for climbing up the cable from ground to over head line including all accessories, material, labours and T&P required for proper completion of work as per specification as per SIDC Sch. No. 25.1 |
| 32 | Supply and laying of aluminium conductor PVC insulated, armoured, served, sheathed cable 1100 V grade of Havell,s/Grandlay/Gloster/Polycab/KEI Make at a depth of 750 mm below ground level in existing HDPE/DWC/GI Pipe complete in all respects. {as per PWD Sch. No. 501(n) - Sch No. 507 } 95 sq.mm 3.5 core |
| 33 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respects as per direction of the Engineer-incharge as per UPPWD Sch. No. 504 (i)95 sq.mm |
| 34 | S/F of brass nickel plated compression gland for PVC insulated and armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-in charge as per UPPWD Sch. No. 503 (n)95 sq.mm 3.5 core |
| 35 | Providing and fixing of precast reinforced cement concrete 1:1.5:3(1 cement:1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement:3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35x93.5x10 cm size. |
| 36 | Finishing with epoxy paint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concrete work. |
| 37 | Lettering with black Japan paint of approved brand and manufacturer. |
| 38 | Constructing brick masonry chamber (inside dimentions 900x800 mm and 60 cm deep for single pipe line) for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover with frame to be not less than 38 Kg. (weight o'cover 23 Kg. and weight of frame 15Kg.) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. |
| 39 | Supply & fixing of LED Strip light with red, white and green (3 colour) in overall 18 Mtr. length (each colour 6 mtr.respectively) complete with LED strip driver (for each colour) etc.(complete with 01 year warranty for replacement from the date of work completion (Philips,Crompton,Bajaj Make) complete in all respect |
| 40 | Supply and fixing of 12.5 mtr. High mast shaft of approved make with Rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm.Top dia minium 150 mm bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferntial weld, with accessoies for high mast such as head frame suitable for 6 limminaries & its control gear boxes,75 HP power tool moter 3 point suspension system with steel wire rope 6 mm. dia double drum winch including making suitable foundation as per manufature drawing/ site requirment along with foundation bolts nuts, washer, anchor plates etc complete in all respects as per UPPWD Sch. No.651 (Bajaj/Crompton/Philips/Approved Make) |
| 41 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 200 watt confirming to IP 66 protection complete in all respects (With 5 Year Gaurantee). Catt. AA as per UPPWD Sch. No.1455 (Bajaj/Philips/Crompton/Wipro Make) |
| 42 | Supply & fixing of LED street light fittings having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt LED light confirming to IP 66 and above protection complete in all respect as per UPPWD Sch. No.1424 CAT- AA (Bajaj /Philips/Crompton/Wipro Make) |
| 43 | Supply & wiring of submain with 2 Nos.of 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P reuired for proper completion of the work as directed as site by Engineer I/C as per UPPWD Sch. No.289 |
| 44 | S/F of following capacity of automatic street light cubical cantrol panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 series with cintractors HRC fuses, isolating switch metering instuments box with CTS etc. as per UPPWD Sch. No. 807(d-ii)25 Amp.TPN) |
| 45 | Supply & laying 16 sq mm 4 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE/GI pipe &Surface laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(i) & 507 (Polycab/Havells/ Grandlay/Gloster/KEI Make) |
| 46 | Supply & laying 25 sq mm 3.5 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE/GI pipe &Surface laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(j) & 507 (Polycab/Havells/Grandlay/Gloster/KEI Make) |
| 47 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer - incharge as per UPPWD sch. no. 503 (i) 16 sq. mm 2 core |
| 48 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer-incharge as per UPPWD sch. no. 503 (k) 25 sq. mm 3.5 core |
| 49 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm |
| 50 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (f) 25 sq. mm |
| 51 | Supply & Laying of 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect. |
| 52 | Supply & Laying of 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. througth horizontal boring trenchless (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect |
| 53 | supply and fixing of 32 mm dia 1.20 mtr long GI pipe bracket including bend pipe ,2 nos 50x6 mm ms clamp in all respect |
| 54 | S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect as per UPPWD Sch. No.701 |
| 55 | Supply & Fixing of 25 x 3 mm GI strip from earth electrode directly in the ground as required complete in all respect. as per UPPWD Sch. 716 |
| 56 | Fabrication,Supply & Fixxing of work information board in M.S frame made by 50 mm dia sqaure pipe of stainless steel grade SS-304 &16 mm thick base plate with back supporting of bracing by MS flat of 25x6 mm and 2.85 Mtr. Long supporting leg made from 65mm pipe SS-304 grade with proper grouting arrangement. The board should be Retro reflective type in green colour with white letters as required and shall be fixed at a height of 1.2 Mtr. from ground by providing 0.45x0.45x0.60 Mtr. cement concrete stone pad Please Enable Macros to View BoQ information |