| 1 | Supply & erection of, 8.5 mtr. 410 SP-17 (Approx. wt. 92kg.) Steel tubular pole with 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement: 3 coarse sand: 6 stone ballast) including plinthing of pole 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. Complete in all respect as per direction of E-l/c.GNIDA SOR 2024/SL. No.27A |
| 2 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 50 Watt. (Cat-AA) Confirming to IP66 Protection complete in all respect.UPPWD 2018/SI. No.1421 |
| 3 | Supply, delivery, testing, laying of Al. conductor HDPE/XLPE insulated 1100V grade Arial Bunched Cable with Messenger wire on pole complete in all respect. (CCI, Gloster, Asian, Universal, NICCO, ICL, Diamond, Havells, Kalinga, Suraj, Delton Grandley & Polycab, make) Complete in all respect, as per the direction of E-I/c. (2C x 25 Sqmm. + 1C X 25 Sqmm)GNIDA SOR 2024/SL. No.65B |
| 4 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.UPPWD 2018/SI. No.501 |
| 5 | 16 sq. mm 4 core (i) |
| 6 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.UPPWD 2018/SI. No.503 |
| 7 | 16 sq. mm 4 core (i) |
| 8 | Supply and fixing of plain or pin type copper tin plated . cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.UPPWD 2018/SI. No.504 |
| 9 | 16 sq. mm |
| 10 | Numbering of poles with combination of yellow and . black colour paint etc. complete in all respect as per direction of the Engineer-Incharge at SITESOR 42/FTS No.128181 |
| 11 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG Gl wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing.UPPWD 2018/SI. No.701 |
| 12 | Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint.UPPWD 2018/SI. No.623 |
| 13 | Supply and Fixing 40mm. dia 1.5mtr. Long G.I. pipe 'B' Class bracket with 2 Nos. 'D' clamps 50X6mm. flat iron on steel tubular pole / PCC pole with bolts, nuts etc. complete in all respect, as per direction of E-I/C.GNIDA SOR 2024/SL. No.38 |
| 14 | Supply & fixing of 75 mm x 90 mm shackle insulator 2018/SI/100 mm x 65 mm pin insulator including G.I. Bolts /spindle nuts etc. complete in all respect.UPPWD 2018/SI. No.620 |
| 15 | Supply & Fixing HDPE pipe 160 mm dia PE-63/PN-4 including required material, T&P Etc. Complete in all respect as per direction of E-l/c.GNIDA SOR 2024/SL. No.21 |
| 16 | Supply and Fixing 50 Sqm to 16Sqm LT ABC Connector on Pole complete in all respect, as per . direction of E-I/C.GNIDA SOR 2024/SL. No.39 |
| 17 | Supply & erection of stay set at least 3.5 Metres away . from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 cm x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19 mm x 600 double screw tightener, 7/4.00 mm G.I stay wire etc. in 1:3:6 cement concrete complete in all respect.UPPWD 2018/SI. No.630 |
| 18 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect.UPPWD 2018/SI. No.634 |
| 19 | Supply & Fixing HDPE pipe 90 mm dia PE-63/PN-4 including required material, T&P Etc. Complete in all respect as per direction of E-l/c.GNIDA SOR 2024/SL. No.19 |
| 20 | Supply & Fixing of MS rod for earthing with 2.5 m long, solid, 20 mm dia hot dipped galvanised MS rod buried . till the top reaches 1.7 mts. below the GL complete with bolts & nuts & Gl earth wire 7/14. Complete in all respect, as per direction of E-I/C.GNIDA SOR 2024/SL. No.41 |
| 21 | Supply and Wiring of submains with two nos. of 2.5 sq. . mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in chargeUPPWD 2018/SI. No.289 |
| 22 | Supply and laying of 32 mm x 6 mm G.I. strip from . earth electrode directly in the ground as required complete in all respect.UPPWD 2018/SI. No.717 |
| 23 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.UPPWD 2018/SI. No.807 |
| 24 | 40 A TPN (F-ii) |
| 25 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |