| 1 | Specifications of heritage architectural ornamental decorative cast iron pole having provision to fix decorative aluminum light fixture (post top) Installation of same with foundation bolts of suitable size to grout it into specially designed enclosed drawing. The details of pole are given below: -The Pole: The pole shall look like as shown in the drawing. It shall have all similar features as shown in the enclosed drawing/picture. The Cast Iron Pole of nearly 3500mm length. The pole also has ornamental base (Approx.overall dimension-height 1040mm,bottom dia 370mm) shall have a provision of inbuilt junction box for fixing MCB’s or cutouts with detachable window cover. The part above ornamental base design consists of decorative sections of circular shape with traditional Chinar leaves bamboo design tapered shaped decorative Bamboo in different dimension, is made of cast iron in fine finish. The design of the cast-iron parts is clearly shown in the drawing. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%) Light Fixture: The ornamental aluminum casted decorative suspended, pendent/hanging type light fittings of total height nearly 610mm having suitable Adopter/connector for fixing on required post; as shown in the enclosed drawing/picture. The fixtures have aluminum casted for better look. It shall have designed to illuminate large areas with its wide dispersion without affecting the environment. It shall have polycarbonate frosted glass, light cover with stainless-steel fastening elements. The fixture having provision to fix complete with required power supply. The designs of cast aluminum light fixture shall be similar to the once shown in the drawing. The fixture having provision to fix complete with required power supply; The designs of cast aluminum light fixture shall be similar to the once shown in the drawing. The fixture having provision to fix complete with required power supply; The fixture having fitted with LED panel of 45-50 Watt (100Lumens/watt and LED lens should be Osram /philips or euivalant make) The luminaries must have rated with IES LM-79-08(As per IEC62262:2002) & IP-66 rated The main structural components of fixtures have UV resistant & shock resistance IK08 (As per IEC62262:2002) with tilting frame for access to the electric & optical auxiliary compartment with silicon gaskets fixing. As regarding the electrical auxiliaries for LED module of 50watt with IP protected polycarbonate Kathod Lens & input frequency of 50Hz ;THD <10% with inbuilt surge protection of 5KV AC of & High Grade Heat sink in extruded aluminum with Silicon Compound Used for PCB Heat transferor. Each LED with specific Kathod lens for uniform photometric distribution. The Lightone LED driver shall be Water proof, With Aluminum casing covering with silicon potting with efficacy <85%.The LED efficiency of 45 to 50 Lumen/watt; it has support plates for LED module & wiring easily removable. It has appropriate space for auxiliary devices for plate wiring. It is responsibility of the installer the correct installation & electric connection in accordance with applicable regulation. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%) Finish: Colour specification & finishing process must follow as per the ISI standard. All parts must be clean by SHOT blasting process. Further parts are painted in 4 layer coating(Coating thickness-125 to 150 micron) in which first layer with epoxy primer(to prevent corrosion),second layer with epoxy base colour,than third layer polyurethane (PU) metallic paint (Gold/Green/Copper/Silver) & final layer of polyurethane (PU) lacquer (to prevent ultra violets ray). Material Specification: All this above parts made of cast iron castings must be of FG-150 grade as per IS 210 (2009) standard, Hardness must be in range between 130 BHN to180 BHN. Cast iron must have Chemical composition of Carbon -3.0% to 4.0% Silicon- 1.0% to 2.0%, magnesium -0.5% to 0.7%,sulpher -0.02% to 0.04% & phosphorous-0.07% to 0.09% this composition is best suitable for product strength & life. the Manufactures name and departmental logo shall be embossed on the bottom section of the pole appropriately |
| 2 | Supply installation testing and commissioning of Heritage architectural ornamental decorative cast iron pole as per above specification/ enclosed drawing Dwarka /Karara Mujasame / Hilite/ crompton / Halonix Make including 63 Amp 4 way connector, MCBs 1 or 2 Amp and Lugs as required |
| 3 | Digging a pit approximately size 2x2 ftx 2.5 ft underground and raising above ground 1.5x1.5ft of 1.25ft height above ground either square or round shape of 1.5Ft dia to be decided by site engineer for Providing and laying of Reinforced cement concrete foundation as per specifications/enclosed drawing including foundation nuts, bolts and with tar steel of required size welded together firmly with reinforcement properly, cement concrete to be carried in 1:2:4 mix. including the cement concrete as per the enclosed drawing including its form work using MS Plate Shuttering. the item includes all carriages upto site, curing and removal of excavated earth complete job. |
| 4 | Providing of earthing using GI pipe Electrode of 1.5 ft to be driven into earth from pole pit bottom and extending the earth upto earth point of pole using 10 SWG GI wire welded togather with earth electrode. The earth should be fixed with earthing point of pole properly. |
| 5 | Supply fixing testing and comm.of decorative ornamental translucent luminarie as specified at item No 1 above of Philips// Osram/Wipro/Dwarka /Karara Mujasame / Hilite/ crompton / Halonix /ELteck india Ltd/ Bajaj Make.Further the fixture should be fitted with pole bracket properly. item should be with 2 yrs warranty Item should be with 2 yrs warranty |
| 6 | S/L , testing and commissioning of PVC aluminium un-armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Polycab/ KEI/ Paraflex/ Apar or Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. including adequate dia of HDPE Pipe to be directed by the Site inchage engineer .the HDPE pipe should be of IS Standard quality. the cable shall be provided with end termination lugs / thimbles including of its crimping and taping. the item includes excavation of earth work in hard / rocky/ dense soil for cable trench, 1.5 to 2 ft deep with an average breadth of 1.5ft and refilling of trench with excavated earth after laying of cable in HDPE pipe and ramming it properly excluding cost of cable and HDPE Pipe. the item includes removal of surplus excavated earth. |
| 7 | a) 35 sq.mm 4 core |
| 8 | b) 25 sq.mm 4 core |
| 9 | b) 16 sq.mm 4 core |
| 10 | a) 10 sq.mm 4 core |
| 11 | Providing of service connection and earthing's to luminaire from the junction box in 1.5 mm PVC insulated multistrand, copper wire of Havelles/polycab/KEI or equivalant make including end termination lugs / thimbles including of its crimping and taping |
| 12 | S/I testing and comm. Of three phase 50 KVA 50HZ oil cooled, unbalanced type servo voltage stabilizer(A.E / Cosco/Chinar/ Electricfield make) having an input voltage ranging from 156V to 415 V ( phase to phase) and balanced output voltage of 415V, +/- 1%.(Transformer oil is to be provided with stabilizer conforming to IS 335,IEC296)) ( Test certificate to be provided by the manufacturer).the stablizer should be installed on prelaid foundation( excluding cost of foundation) and enclosed in a kiosk to be paid seperately .The unit incorporate |
| 13 | a) 0-500V moving iron type voltmeter with selector switch. |
| 14 | b) A three phase change over switch to read voltage on incoming and output side |
| 15 | c) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit. |
| 16 | d) six push button control for movement operation of three motorised dimmer units two for each unit i.e one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDT) |
| 17 | e) Single phase Preventer ( contactor Switch of required rating) Legrand / equivalant make. |
| 18 | f) six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control. |
| 19 | g) two sets of indication lamps three numbers each to indicate output and input indication |
| 20 | h) 20 % over load bearing capacity for one hour. |
| 21 | i) the servo stablizer shall be provided a set of low and high voltage protection using proper rated Contactors with with allied items as required for the protection |
| 22 | Carrying out foundation of PCC type, cement concrete to be carried in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)in foundation of servo stabilizer set, panel etc including form work etc as required the job also includes supply and carriage etc of the requsite material upto the site. |
| 23 | Providing of earthing by way of digging 10' deep pit then embedding 2'x2', 5mm thick copper plate connecting the plate with main control board by 10 SWG copper wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with alternate layers of salt coal and earth. |
| 24 | P/F of sheet steel Kiosk suitable to house 50 KVA servo stabilizer fabricated out of 16 SWG M.S sheet having front door with locking arrangements and duly powder coated. To be installed on prelaid foundation to be paid seperately |
| 25 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of panel machine fabricated made out of 16SWG thick M.S. sheet of adequate / required size to house all the equipment, floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs grouted in the cement concrete., with lockable type hinged doors, duly powder coat painted with provision for fixing of incomer MCCB, outgoing DP MCBS, sets of Aluminium Bus Bar of different rating. after taking Derating factor into account, and other allied accessories etc. as required. the panel to be fabricated from reputed firm duly approved by CPRI.as per approved design, size may vary as per site requirement) the item includes |
| 26 | INCOMING: |
| 27 | b)100 amp TPN MCCB 35 KA including spreader links, ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/L&T/ABB/BCH/equivalant make. (1 No.) |
| 28 | b) TPN of Aluminium Bus Bar of required capacity. (2 set) |
| 29 | c)Digital meters and phase indicators -1 set. (1 set) |
| 30 | d) Astronomical timer with 4 pole contactor of suitable capicity. Legrand/ L&T /ABB / equivalqnt make (1 set) |
| 31 | OUTGOING: |
| 32 | a) 40/32 amp TPN MCB (3 No.) |
| 33 | b) SP MCB of required capacity (9 No.) |
| 34 | Complete unit |
| 35 | Cutting of macdamized road for laying of 3 inch OD GI pipe B class at cable crossing points. The cutting shall be done properly upto 6 inch width 9 inch depth using proper equipments and filled back with 1:1.5:3 cement concrete mix level to the road surface with finish at various spots |
| 36 | Providing and laying of B class GI pipe 3Inch OD With requied collar/ bends and threads. The item includes providing of earthing of the laid pipes as per standard |
| 37 | Sub station Part: 63 KVA Distribution Substation I |
| 38 | 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al. wound upto 63kVA ratings) , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable.( X-mer without OCTC (Off Ckt Tap Changer)) |
| 39 | 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 40 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 41 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 42 | 70mm² (1Ckt for 63 kVA),120mm² (1Ckt for 100 kVA),185mm² (2Ckt for 200kVA) ,240mm² (2Ckt for 250kVA) single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type (44mtr for 1 Ckt) |
| 43 | 9 Mtr. Long Pole,(ST-410 SP33) |
| 44 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting |
| 45 | GI Channel/Angle/Flat of sizes including clamps |
| 46 | Galvinized Nuts and Bolts. |
| 47 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 48 | Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm |
| 49 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 50 | LT Distribution Box for:- i) 63 kVA DTR with 100 Amp MCCB 3P 16 kA and 200Amp TPN busbar with mounting GI channel iron of required size and clamps and earthing |
| 51 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 52 | Wedge Connectors / PG Clamps |
| 53 | Danger Plates with Clamps |
| 54 | GI Barbed Wire for Anti Climbing |
| 55 | 3-Ø, 4-Wire Trivector Meter (Prodigy ) with suitable ring type CT 200 Amp including all necessary hardware for installation |
| 56 | Cement bottoming 1:2:4 mix as per Standards 0.48 cum/pole |
| 57 | Painting of Poles Red Oxide |
| 58 | Painting of Poles Aluminium Paint |
| 59 | Sundry items like Aluminium lugs, Jumpers, Binding Tape, |
| 60 | 11kv, 35 sqmm 3 core XLPE cable including outorr type termination kits complete job to be layed U/G or over head as per site conditions |
| 61 | Supply and laying of ACSR 0.03 fron the nearest 11Kv tapping point upto substation including all the hardware and accessories Please Enable Macros to View BoQ information |