| Sl. No. | Item Description |
| 1 | Dismantling of |
| 2 | 11KV VCB Panel complete |
| 3 | 33KV C&R Panel complete |
| 4 | 33KV VCB / MOCB complete |
| 5 | Installation, testing and commissioning of Switchgear System complete (material to be provided by the department) |
| 6 | 11KV VCB Panel complete |
| 7 | 33KV C&R Panel complete |
| 8 | 33KV VCB complete |
| 9 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Allind Panels |
| 10 | Supply,installation,testing,commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable 11KV VCB panels of make Eason Reyrol / Vijay/Pascal/Stelmec |
| 11 | Installation, testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panels) |
| 12 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards (for 11KV VCB panels) outdoor type |
| 13 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards (for 11KV VCB panels) Indoor Type |
| 14 | Installation, testing and commissioning of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panel) outdoor type |
| 15 | Installation, testing and commissioning of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panel) Indoor Type |
| 16 | Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel |
| 17 | Alsthom make |
| 18 | Easun Reyroll Make |
| 19 | Vijay Make |
| 20 | Sudhir Make |
| 21 | Electric Field |
| 22 | Crompton Greeves |
| 23 | Allind |
| 24 | ABB Make |
| 25 | Providing and fixing of female contact (complete assembly) for 11KV VCB by way of Replacement of Damaged/Burnt Out female contact set of same composition,type,make and class already installed in 11KV VCB panel |
| 26 | Alsthom make |
| 27 | Easun Reyroll Make |
| 28 | Vijay Make |
| 29 | Sudhir Make |
| 30 | Electric Field |
| 31 | Crompton Greeves |
| 32 | Allind |
| 33 | ABB Make |
| 34 | Providing and fixing of 11KV Vacuum Interrupter by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interrupter of same composition,type,make as already installed in 11KV VCB panel (1250amps) |
| 35 | Fixing of fresh 11KV Vacuum Interrupter by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interrupter of same composition,type,make already installed in 11kv vcb panel (material to be provided by the department) |
| 36 | Supply,installation,testing and commissioning of Numerical/Digital Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type, make and class already installed in panel. All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts |
| 37 | Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A) by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel.(material to be provided by the department) |
| 38 | Rectification,Re-Alignment,setting right the electrical section of 11KV Breakers (11KV VCB panel) |
| 39 | Rectification,Re-Alignment,setting right the mechanical section of 11KV Breakers (11KV VCB Panel) |
| 40 | Rectification,Re-Alignment,setting right the electrical section of 33KV C&R panel |
| 41 | Rectification,re-alignment,setting right the mechanical section of 33KV VCB |
| 42 | Replacement of spring Charging motor of 33 KV VCB( To be provided by the Department) |
| 43 | Supply,installation,testing,commissioning of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) with fresh one complete. |
| 44 | Supply,installation,testing,commissioning of Tripping/closing coils suitable for 11KV VCB Panels like Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T etc |
| 45 | Providing and fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps, Transformer Clamps(Both H.V & L.V Side),Pad Clamps) |
| 46 | Providing and fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type) |
| 47 | Providing and fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type) |
| 48 | Providing and fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type) |
| 49 | Providing and fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) |
| 50 | Supply,installation,testing and commissioning of fresh 33KV C.T (3-core) confirming to IEC:185 and IS:2705 (part-1 to 4) standards of ratio 600-300/5-5-5A/ 400-200/5-5-5A) outdoor type |
| 51 | Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio. |
| 52 | Supply, installation, testing and commissioning of 33KV P.T of (110V/√3) confirming to IS:3156 (part-I to Part-III) outdoor type |
| 53 | Fixing,installation,testing and commissioning of fresh 33KV PT (110V/√3) |
| 54 | Providing and fixing of 33KV isolator 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards |
| 55 | With earthing blade |
| 56 | Without earthing blade |
| 57 | Fixing,installation,testing and commissioning of fresh 33KV isolators |
| 58 | Supply. Installation, Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps. |
| 59 | Installation, Testing and commissioning of 33KV link set |
| 60 | Supply,Installation,Testing and commissioning of 11KV G.O Set 850 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one |
| 61 | Installation, Testing and commissioning of 11KV G.O Set |
| 62 | Providing, fixing, installation, testing and commissioning of 11KV Isolators,600amps. conforming to IS 9921/IEC-129 standards |
| 63 | With earthing blade |
| 64 | Without earthing blade |
| 65 | Installation, Testing and commissioning of 11KV Isolators, |
| 66 | Supply, Installation, Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damaged one heavy duty 600amps. |
| 67 | Installation, Testing and commissioning of 11KV link set |
| 68 | Supply, Installation, Testing and commissioning of 33KV Drop out set with porcelaine insulator by way of replacement of damaged one as per latest IS standard with latest amendments thereof. |
| 69 | Installation, Testing and commissioning of 33KV D.O. set by way of replacement of damaged one |
| 70 | Supply, Installation, Testing and commissioning of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments thereof. |
| 71 | Installation, Testing and commissioning of 33KV L.A. set by way of replacement of damaged one . |
| 72 | Oil Toping in 33/11 KV Power Transformers and 33KV MOCB's (Transformer oil to be supplied by the department) |
| 73 | Supply, installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers |
| 74 | Supply, installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers |
| 75 | Providing and fixing of interrupting chambers (Housing Assembly) suitable for 11KV VCB of different make by way of replacement of damaged one |
| 76 | Crompton Greeves |
| 77 | Vijai |
| 78 | Alasthom |
| 79 | Easun Rey roll |
| 80 | Electric Field |
| 81 | Supply,installation, testing and commissioning of Arcing interrupting chambers suitable for 33 KV VCB panels of different make by way of replacement of damaged one |
| 82 | Supply, installation, testing and commissioning of spouts bushing suitable for 11KV VCB (Allind-Make) panel of different make by way of replacement of damaged one |
| 83 | Supply, installation, testing and commissioning of spouts bushing suitable for 11KV VCB (Alasthom/Easun Reyroll/Vijay/Sudhir/Electric field/Crompton greeves/ ABB-Make) panel of different make by way of replacement of damaged one |
| 84 | Supply, installation, testing and commissioning of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one |
| 85 | 33KV side |
| 86 | 11KV side |
| 87 | Supply ,installation, testing and commissioning of 30V,100 AH Maintenance free Battery Bank ( comprising of 15 number battery cells of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/AMAR Raja or equivalent make |
| 88 | Supply,installation,testing and commissioning of automatic 30V, Float‐Cum‐Boost Charger With Full waverectification for 220 V, 1Phase, 50 HZ AC Input Supply . Copper wound suitable for 100 to 200 AH |
| 89 | Supply ,installation, testing and commissioning of 2V,100 AH Maintenance free Battery cell |
| 90 | Replacement of damaged 2V,100 AH Maintenance free Battery cell (Dry type) To be provided by the department |
| 91 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,3-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 92 | 630mm^²,3-core |
| 93 | 400mm^²,3-core |
| 94 | 300mm^²,3-core |
| 95 | 240mm^²,3-core |
| 96 | 185mm^²,3-core |
| 97 | 150mm^²,3-core |
| 98 | 120mm^²,3-core |
| 99 | Laying,Testing,commissioning of 11KV (E) grade armoured ,3-core,Xlpe Power Cable |
| 100 | 630mm^²,3-core |
| 101 | 400mm^²,3-core |
| 102 | 300mm^²,3-core |
| 103 | 240mm^²,3-core |
| 104 | 185mm^²,3-core |
| 105 | 150mm^²,3-core |
| 106 | 120mm^²,3-core |
| 107 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,1-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 108 | 630mm^²,1-core |
| 109 | 400mm^²,1-core |
| 110 | 300mm^²,1-core |
| 111 | 240mm^²,1-core |
| 112 | 185mm^²,1-core |
| 113 | 150mm^²,1-core |
| 114 | 120mm^²,1-core |
| 115 | Laying,Testing,commissioning of 11KV (E) grade armoured ,1-core,Xlpe Power Cable |
| 116 | 630mm^²,1-core |
| 117 | 400mm^²,1-core |
| 118 | 300mm^²,1-core |
| 119 | 240mm^²,1-core |
| 120 | 185mm^²,1-core |
| 121 | 150mm^²,1-core |
| 122 | 120mm^²,1-core |
| 123 | Supply,laying,Testing,commissioning of 2.5 sqmm Control cable armored , copper conductor sheathed PVC insulated multi colour voltage grade 1.1 KV conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 124 | 2 core |
| 125 | 4 core |
| 126 | 6 core |
| 127 | 8 core |
| 128 | 12 core |
| 129 | Laying,Testing,commissioning of 2.5 sqmm Control cable |
| 130 | 2 core |
| 131 | 4 core |
| 132 | 6 core |
| 133 | 8 core |
| 134 | 12 core |
| 135 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make) |
| 136 | 630mm^²,3-core |
| 137 | 400mm^²,3-core |
| 138 | 300mm^²,3-core |
| 139 | 240mm^²,3-core |
| 140 | 185mm^²,3-core |
| 141 | 150mm^²,3-core |
| 142 | 120mm^²,3-core |
| 143 | Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) |
| 144 | 630mm^²,3-core |
| 145 | 400mm^²,3-core |
| 146 | 300mm^²,3-core |
| 147 | 240mm^²,3-core |
| 148 | 185mm^²,3-core |
| 149 | 150mm^²,3-core |
| 150 | 120mm^²,3-core |
| 151 | Supply, Installation,Testing and commissioning of 11KV cable termination kits (outdoor Type) 3M or Raychem |
| 152 | 630mm^²,3-core |
| 153 | 400mm^²,3-core |
| 154 | 300mm^²,3-core |
| 155 | 240mm^²,3-core |
| 156 | 185mm^²,3-core |
| 157 | 150mm^²,3-core |
| 158 | 120mm^²,3-core |
| 159 | Installation,Testing and commissioning of 11KV cable termination kits |
| 160 | 630mm^²,3-core |
| 161 | 400mm^²,3-core |
| 162 | 300mm^²,3-core |
| 163 | 240mm^²,3-core |
| 164 | 185mm^²,3-core |
| 165 | 150mm^²,3-core |
| 166 | 120mm^²,3-core |
| 167 | Supply,installation,testing,commissioning of 11KV ,1 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make) |
| 168 | 630mm^²,1-core |
| 169 | 400mm^²,1-core |
| 170 | 300mm^²,1-core |
| 171 | 240mm^²,1-core |
| 172 | 185mm^²,1-core |
| 173 | 150mm^²,1-core |
| 174 | 120mm^²,1-core |
| 175 | Installation,testing,commissioning of 11KV ,1 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable |
| 176 | 630mm^²,1-core |
| 177 | 400mm^²,1-core |
| 178 | 300mm^²,1-core |
| 179 | 240mm^²,1-core |
| 180 | 185mm^²,1-core |
| 181 | 150mm^²,1-core |
| 182 | 120mm^²,1-core |
| 183 | Supply, Installation,Testing and commissioning of 11KV cable termination kits (outdoor Type) 3M or Raychem |
| 184 | 630mm^²,1-core |
| 185 | 400mm^²,1-core |
| 186 | 300mm^²,1-core |
| 187 | 240mm^²,1-core |
| 188 | 185mm^²,1-core |
| 189 | 150mm^²,1-core |
| 190 | 120mm^²,1-core |
| 191 | Installation,Testing and commissioning of 11KV cable termination kits |
| 192 | 630mm^²,1-core |
| 193 | 400mm^²,1-core |
| 194 | 300mm^²,1-core |
| 195 | 240mm^²,1-core |
| 196 | 185mm^²,1-core |
| 197 | 150mm^²,1-core |
| 198 | 120mm^²,1-core |
| 199 | Unloading of bulky material which are to be handled with care like 33kKV CT/ |
| 200 | Loading of bulky material which are to be handled with care |
| 201 | Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc |
| 202 | Upto first 100mtr lead |
| 203 | For every additional 50mtr or part there off |
| 204 | Unloading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage from dumping site upto proper stacking |
| 205 | Loading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage stacking site upto loading |
| 206 | Supply ,installation,testing and commissioning of copper Bus Bar |
| 207 | installation,testing and commissioning of copper Bus Bar |
| 208 | Repairing /Replacement of 11KV VCB's |
| 209 | Tripping and closing Mechanism repair |
| 210 | Tripping and closing Mechanism replacement |
| 211 | Re-setting links |
| 212 | Replacement of operating shaft |
| 213 | Shower contact |
| 214 | Isolating Sockets |
| 215 | Replacement of damaged gears complete set |
| 216 | High Tension spring |
| 217 | Tripping shaft |
| 218 | Rollers |
| 219 | Latch assembly |
| 220 | Replacement of Copper Shims |
| 221 | Replacement of Spring Charging motor |
| 222 | Deco spray painitng |
| 223 | Transportation of Power Transformer of capacity (3.15/4 MVA/5MVA) complete job including all neceesary accessories |
| 224 | Transportation of Power Transformer of capacity (6.30/10 MVA) complete job including all neceesary accessories |
| 225 | Installation,Testing and commissioning of Power Transformer of capacity (3.15/4 MVA/5MVA) complete job including all neceesary testing at site |
| 226 | Installation,Testing and commissioning of Power Transformer of capcity (6.3 MVA/10MVA) complete job including all neceesary testing at site |
| 227 | Dismantling of Power Transformer of capacity (3.15/4 MVA/5MVA) complete job |
| 228 | Dismantling of Power Transformer of capcity (6.3 MVA/10MVA) complete job |
| 229 | Supply,fixing,testing and commissioning of 100 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 36 kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage(Use) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.ABB/EATON/L&T/SCHNEIDER/SEIMENS/LEGRAND/HAVELLS MAKE |
| 230 | Supply,laying,Testing and Commissioning of 50 mm sq 4core 1.1 KV grade , stranded Aluminium Conductor, XLPE insulated PVC Outer Sheathed, armoured cable FRLS (Havel's/Gloster/Paramount/Grandlay) as per IS-7098 amended up to date |
| 231 | Earthing using 40mm GI pipe or 20mm Gi rode, 2.5 Mtr long complete as per REC Standard and connection with near by mesh using GI Strip of 50*6mm. |
| 232 | Supply Installation Testing and commissioning of 33KV VCB (36 KV , 1250 Amp, 26.2 KA, Outdoor type) with all accessories mounting standard and foundation with foundation bolts as per REC Standard. |
| 233 | Supply Installation Testing and commissioning of 33KV C&R Panel along with O/C, E/F and differential relays, (IEC 61850), mimic diagram, volt meter, ammeter, annun ciation windows with annunciation relays, 3Phase triviocter meter 5Amp DLMS complaint with rs485 port with auxiliary relays and semaphore. |
| 234 | Supply Installation Testing and commissioning 11KV VCB Panel board with breaker (12KV, 1250 Amp, 25KA, indoor) along with O/C, E/F (IEC61580), mimic diagram, volt meter, ammeter, annun ciation windows with annunciation relays, 3Phase triviocter meter 5Amp DLMS complaint with rs485 port with auxiliary relays and semaphore. (Incomer) (400-800Amp CT) |
| 235 | Supply Installation Testing and commissioning 11KV VCB Panel board with breaker (12KV, 1250 Amp, 25KA, indoor) along with O/C, E/F (IEC61580), mimic diagram, volt meter, ammeter, annun ciation windows with annunciation relays, 3Phase triviocter meter 5Amp DLMS complaint with rs485 port with auxiliary relays and semaphore. (Outgoing) (400-800Amp CT) |
| 236 | Providing and laying of Cement Concrete using 1:2:4 ration for foundations / pole bottoming etc. (Job include execution , stone soling and formwork above ground including plaster using 1:4 ratio. |
| 237 | Providing, cutting, bending and fixing using binding wire of tar steel twisted TMT bars of sizes. (16mm,12mm, 10mm and 8mm) |
| 238 | Supply Installation Testing and commissioning of 12 Volt Battery 180 AH (Exide, Amron, Microtex, Luminous) warranty to be provided as per company's time. |
| 239 | Installation Testing and commissioning of 12 Volt Batteries 180 AH |
| 240 | Providing and fixing of yard lights of 50/60 W watt with complete brackets |
| 241 | Providing and fixing of GI Iron of sorts design and specification as per site requirements |
| 242 | cutting bending welding drilling and fising of GI/M.S Iron of sorts as per site requirement |
| 243 | SITC of 36 volt 2.5 KVA invertor (DSP base) Latest invertor. |
| 244 | SITC of 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less |
| 245 | Repair of 36/30 Volt battery chargers |
| 246 | Replacement of Damaged DC Volt meter with a fresh piece. |
| 247 | Replacement of Damaged DC Ampere meter with a fresh piece. |
| 248 | Replacement of 30 Ampere Rotor Switch 8 Way |
| 249 | Replacement of LED Light 2w indication Round Type |
| 250 | Replacement of damaged MCB 6/10/16 Ampere with a fresh piece |
| 251 | Replacement of damaged 3 Pin Top 15 Ampere with a fresh piece |
| 252 | Replacement of damaged Wire /Lead 2.5mm2 DC wire with a fresh |
| 253 | Replacement of charger Cabinet with a new cabinet |
| 254 | Rewinding of Charger Coil with 7 No copper gauge 3” wide |
| 255 | Full Rewinding of Battery Charger including Extra Core ,30Ampere Rotor with Full wave Rectifier 60Ampere (4 Pcs ) with heat sink with Ampere Meter |
| 256 | Replacement of damaged Rectifier 60Ampere (4 Pcs ) complete with Board |
| 257 | Replacement of Burnt out droppers/jumpers in switchyard |
| 258 | Setting right of 33 KV Isolators |
| 259 | Setting right of 11 KV Isolators |
| 260 | Cleaning of 11 KV Panels, AC/DC Boards,33 KV CnR Panels |
| 261 | Repairing of Auxialiary transformers by way of replacement of damaged bushes,bush rods thimbles etc. |
| 262 | SITC for Replacement of damaged auxiliary transformers by new one of 63 KVA (Level-II) |
| 263 | Replacement of damaged auxiliary transformers by new one or repaired one (to be provided by the department ) including all carriages installation of new transformer and dismantling of damaged one. |
| 264 | SITC for Replacement of burnt out Aluminium Bus Bars (100*12mm ) of Transformers |
| 265 | Replacement of burnt/damaged bus bars (To be provided by the department) |
| 266 | SITC for Replacement of damaged Bushes of HV/LV of power transformer |
| 267 | Replacement of damaged Bushes HV/LV of power transformers (To be provided by the department) |
| 268 | Complete testing of Relay Setting of Testing Kit,Interconnection between various points of panel with respect to secondary injection key on various current taps,recording of observation thereof.All modifications necessary to achieve desired results. |
| 269 | Upkeeping of earthing of aux, transformer |
| 270 | Upkeeping of earthing of Power transformer |
| 271 | Upkeeping of earthing of66/33/11 KV LA |
| 272 | Upkeep of earth mat of outdoor switch yard |
| 273 | 33/11 KV Power Transformer Opening of transformer tank top cover to prevent oil leakage from top (if required to facilitate maintenance of transformer after removing the required accessories ).Draining/Refilling of required oil.Change of gaskets of valves/radiators/Buchholz relay ,Surge crelayconservator,sensors,measurement of IR value diaelectric strength of oil,cleaning of Power transformer of capacity 3.15 MVA to 10MVA |
| 274 | Supply and Replacement of silica Gel |
| 275 | Replacement of silica Gel |
| 276 | General inspection by thorough inspection of each individual parts ,Ratio test by applying voltage on HV side and measuring LV Voltage on various Tap Positions ,checking of Buchholz relay,Surge relay ,Surge relay conservator ,sensors,measurement of IR value dialelectric strength oil,cleaning of Power Transformer etc. |
| 277 | Preventing of leakage by changing main gasket after removing the old gasket Replacement of HV/LV Busing & Bush Rod ,Ring and Rubber Washers (complete job to prevent leakages) |
| 278 | Cleaning of scale deposited over the body and radiators of the power transformer with thinner /detergent and dde-rusting in perfect manner (routine work) |
| 279 | Cleaning of HV/LV Bushings of Power transformer (routine work) |
| 280 | Replacement of HV/LV clamps of Power Transformer |
| 281 | Recording of IR values of transformers |
| 282 | Checking and tightening of of Jumpers ,Droppers in 66/33 Yards |
| 283 | Replacement of worn out/heated Pad clamps /Isolator clamps/isolator clamps of 66/33/11 KV isolator by way of dismantling ,drilling of holes on new and fixing |
| 284 | Topping of oil level of 66/33 KV CT & PT by way of opening of top cover and refixing with new gaskets if necessary and preventing of oil leakages if any (complete job) |
| 285 | Cleaning of porcelein bushing,tightening of CT/PT clamps,derusting & painting of body of 66/33 KV PTs & CTs |
| 286 | Tightening of nuts and bolts,replacement of oval thread bolts chipping by way of welding to the bolts after tightening in a single bay. |
| 287 | Battery Bank Repair and maintenance of battery set including maintaining specific gravity electrolyte level cleaning,checking tightening of battery terminals in all respoects it includes measuring of voltage of each battery cell. |
| 288 | Battery Charger Repair/renovation /battery charger for proper functioning by way of replacement of rectification unit Ammeter, Voltmeter,MCB Cooling fan LED indications buzzer alarms for OV/UV etc. (Complete Job) |
| 289 | Repair and maintenance of AC board,identification of fault in respect of cable and its replacement of damagaed MCCB,Cooling fan,LED indicators,buzzer Lrms for OV/Uvetc complete job |
| 290 | Repair and maintenance of DC board,identification of fault in respect of cable and its replacement of damagaed MCCB,Cooling fan,LED indicators,buzzer Lrms for OV/Uvetc complete job |
| 291 | Cleaning of panels ,removing dirt and dust including ducts and battery bank |
| 292 | Painting of internal/external walls including applying coat of putty/primer and roof by approved brands oil based distemper |
| 293 | Painting of door and window panels of control room by approved brand of paint |
| 294 | Replacement of blown fuses,checking the PT terminal with respect of 11 KV bus bar complete job |
| 295 | De-watering of receiving station to avoid water logging |
| 296 | On site repairing of aux transformer for missing phase LT strip ,LT bush rod LT bush cup,HT bush rod etc.(complete job) |
| 297 | Providing and fixing T-iron frames for doors,windows and ventilators of mild steel T-section ,joints mitred and welded including fixing of necessary butt hinges and screws and applying a priming coat of approved |
| 298 | Roof top treatment to prevent water leakage of control room |
| 299 | Repairing of receiving station mesh fencing /chain link mesh fencing height upto 8ft |
| 300 | Watering of earthing Pits |
| 301 | Cleaning of ACD/DC,DBDC Board,RTCC Charger,Battery bank,Solar Batteries other alike small equipments |
| 302 | Cleaning of 66/33 KV CR panel using vacuum cleaner from inside with proper care from outside with thinner /varnish and making66/33 KV CR panel Vermic Proof |
| 303 | Cleaning of 11KV panel using vacuum cleaner from inside with proper care from outside with thinner /varnish and making it Vermic Proof to avoid rodent faults |
| 304 | Extension of control room building |
| 305 | Truss for control room building/Office/Quarters 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing |
| 306 | Replacement of Smart meters on 33KV CnR/11KV Panels |
| 307 | Identification of damaged portion of power cables of 33/11 KV,tracing of fault in cable,removal of cable from trench carriage and laying of cable (complete job) including cleaning of cable trenches |
| 308 | Cleaning of cable duct ,removing of duct covers and placing back after cleaning including disposal of rubbish/dirt upto 50 Mtr lead. |
| 309 | Cleaning of gantry structures like beam,coulmns,VCB structures,PI structures,Isolator structures to remove dust and dirt |
| 310 | Painting of gantry structures including cleaning,making smooth surface applying one coat of red oxide paint and two coats of Aluminium paint |
| 311 | Repairing of existing earth mat after digging ,repairing and filling back |
| 312 | Clearing of extra earth from yards and disposal upto 50 mtr.to make even surface for cement concreting or gravelling |
| 313 | Providing and laying of garvels of standard sizes for garvalling of switch yards 0.1m thick |
| 314 | 33kv Yard Concreting / Metalling (0.05m lean Pad 1:5:10. and cement concrete 0.1 m 1:3:6 and metal gravel 0.1m |
| 315 | MISCELLANEOUS WORKS |
| 316 | Replacement of OLD/Damaged LED Lamp with new 15 watt lamp (Make Havells,Crompton Greaves,Syska,Philips) |
| 317 | Deweeding of switch yards / Receiving Stations/stores |
| 318 | SITC of Wifi CCTV system with four cameras (two indoor and two out door with built in microphone ,resolution of 4MP coloured ,night vision) with all accessories like DVR, Monitor 1TB data storage, cable etc complete .The oudoor cameras should have range of 200 feet whereas the indoor cameras should have a range of 30 feet. |
| 319 | SITC of CCTV system with four cameras (two indoor and two out door with built in microphone ,resolution of 4MP coloured ,night vision) with all accessories like DVR, Monitor 1TB data storage, cable etc complete .The oudoor cameras should have range of 200 feet whereas the indoor cameras should have a range of 30 feet. |
| 320 | Providing and fixing Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height |
| 321 | Fixing of Chainlink Fencing of 33 kV Yard of Substation byway of Mass Concrete in Foundations and chainlink fencing of 6 ft height (Chain link fencing/mesh to be provided by the department ) |
| 322 | Compound walling of Yard/Control rooms/ land etc, by way ofMass Concrete in Foundations and 228 mm Brick Wall of 2 M height |
| 323 | Providing and fixing Earthing Mat (GI Flat 50 mm x8 mm) at Receiving stations |
| 324 | Fixing of Earthing Mat (GI Flat 50 mm x8 mm) at Receiving stations |
| 325 | SITC for Replacement of damaged/defective 3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energy meters DLMSCompliant Category 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure, ABB) energy meters of 11 KV Vcb Panels |
| 326 | Replacement of damaged/defective 3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energy meters DLMSCompliant Category 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure, ABB) energy meters of 11 KV Vcb Panels energy meters of 11 KV Vcb Panels (To be Provided by the department) |
| 327 | Repairing of plaster of thickness 12 mm to 20 mm in patches of areas 2.5sqm and under inluding cutting the patch in proper shape and preparing and plastering the surface of walls complete including disposal of rubbish to the dumping ground within 50M lead with cement mortar 1:4 (1 cement :4 fine coarse/coarse sand) |
| 328 | Dismantling of cement concrete manually including disposal upto 50 mtr |
| 329 | Laying of foundation for 33 KV self supporting Structure 15mtr Long including setting of stubs complete job |
| 330 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 331 | Wiring for circuit /Sub main wiring alongwith earth wire with the following sizes of FRLS, PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC Conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 332 | Wiring for submain light point/power plug with 2*4 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alogwith 1 No.4sqmm FRLS PVC insulated copper conductor single core for loop earthing as required. |
| 333 | Wiring for submain light point/power plug with 2*6 sqmm sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alogwith 1 No.6 sqmm FRLS PVC insulated copper conductor single core for loop earthing as required. |
| 334 | Supply and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed PVC Conduit as required 1 run of cable |
| 335 | Supply and drawing of Co-axial TV cable RG-6 grade 0.7 mm soild copper conductor PE insulated shielded with fine tinned copper braid protected with PVC sheath |
| 336 | Supply and fixing of following modular type switch/socket on the existing switch box/cover including connections et. as required |
| 337 | 5/6A Switch |
| 338 | 15/16 A Switch |
| 339 | 3 Pin5/6 A Socket outlet |
| 340 | 6 Pin 15/16 A Socket outlet |
| 341 | Telephone Socket Outlet |
| 342 | TV Antenna Socket outlet |
| 343 | Bell Push |
| 344 | Musical Call Bell |
| 345 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 346 | Supplying and fixing of modular blanking plate on the existing plate and switch box but excluding modular plate as required |
| 347 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 348 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 349 | 3 Module (125mmX75mm) |
| 350 | 6 Module (200mmX75mm) |
| 351 | 12 Module (125mmX125mm) |
| 352 | Supply ,Installation ,Testing and commissioning of 1200mm sweep,BEE 5 star rated,ceiling fan with Brush Less Direct Contact(BLDC) Motor,Class of insulation B,3nos Blades,30Cm long down rod ,2 nos Canopies,shackle kit,safety rope ,copper winding,Power factor not less than 0.9,Service value (CM/M/W) minimum 6.00, Air Delivery minimum 210Cum/Min,350 RPM (tolerance as per IS:374-2019), THD less than 10%,remote or electronic regulator unit for speed control and all remaining accesories including safety Pins,nuts bolts,washers,temperature rise =75 Degree C(max) insulation resistance more than 2 megha ohm,suitable for 230 V ,50HZ single phase AC supply ,earthing etc. complete as required. |
| 353 | Supply and fixing of concealed metal box 3\\" |
| 354 | Supply and fixing of metal junction box 4\\" |
| 355 | Supply and fixing of PVC Bends 25 mm |
| 356 | Supply and fixing of light indicator |
| 357 | Supply and fixing PVC batten/angle holder including connections etc. as required |
| 358 | Supply and Fixing of LED Pendant light 25 Watt 4' Long (Make Havells,Crompton Greaves,Syska,Philips,Jaquar) |
| 359 | Supply and Fixing of LED Light 15 Watt (Make Havells,Crompton Greaves,Syska,Philips,Jaquar) |
| 360 | Supply,installation,testing and commissioning of 1.5 Ton,5 star inverter Split AC (Cu) all weather with stablizer (Cu Wound) |
| 361 | Supplying and fixing of following ways surface/recess mounting,vertical type,415 V TPN MCB distribution board of sheet steel ,dust protected,duly powder painted,inclusive of 200 A tinned copper bus bar ,common neutral link,earth bar ,din bar for mounting MCBs( but without MCBs and incomer ) as required interconnections, powder painted including earthing etc. as required. 8 Way (4+24) Double door |
| 362 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutralb bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6Way Double door |
| 363 | Supply and fixing 32 A rating 240/415 V,10 KA \\"C\\" Curve Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection,testing and commissioning etc. as required. |
| 364 | Single pole and neutral |
| 365 | Single Pole |
| 366 | Supply Instllation,Testing and commissioning of 4-core 95 sqmm Aluminium Armoured Cable 1.1 kv grade |
| 367 | Supply and fixing of Exhaust Fan operating on 240/230 V AC,50Hz Supply,300mm sweep (Make Havells,CG,Bajaj,Polycab) |
| 368 | Supply and fixing of LED Street light,90 Watt (energy efficient) with angle bracket complete assembly (Make Havells,Crompton Greaves,Syska,Philips,Jaquar) |
| 369 | Supply installation testing and commissioning of High Mast Light on ST Pole 11m Long with 4 nos LED flood lights of 200 Watt each ,safety Class I,Water proof (Make CG,Philips,Havells,Syska,Osram) mounted on circular ring with control relay panel. |
| 370 | Cement bottoming 1:2:4 mix as per REC standards0.6cum /pole |
| 371 | Applying of Aluminium Paint on ST Poles (two coats ) |
| 372 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 373 | Supply and fixing of PVC Cable (Aluminium) Twin Core 16sqmm |
| 374 | Earthing with Copper Plate 600*600*3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with salt and charcoal/coke as required |
| 375 | Fabrication,supply,installation,testing and commisioning of following panel CPRI approved made out of 2mm thick M.S Sheet floor /wall mounted vermin and dust proof ,indoor/outdoor type with suitable size of angle legs for grouting in the ground with lockable hinged doors duly powder coated and providing and fixing of suitable rating bus bars, and other accessories like voltmeter,indicating lamps,selector switches,MCB strips etc along with provision of space for MCCBs ,COS etc as required |
| 376 | 200A .25 KA,FPMCCB |
| 377 | Aluminium Bus bar 200A 4-Strips |
| 378 | Aluminium Bus bar 400A 4-Strips |
| 379 | Change Over switch 125 A front operatable |
| 380 | Digital metering devices comprising of voltmeter ,Ammeter ,selector switch,Indicating lamp CT Set and MCB Strip of suitable sizes |
| 381 | 35 Litre Water Geyser, 240V 5 star Rated ( Make Havells ,Racold,CG,Voltas,Hindware,)Verticle type |
| 382 | Supply,Installation Testing and commissioning of 5KVA Diesel Generator ( , 3-phase ,50Hz ,insulation Class H,Dry type air filter with low vibration and noise ) including construction of bed earthing and all necessary connections |
| 383 | Supply,Installation Testing and commissioning of 5KVA Diesel Generator (1-phase ,50Hz ,insulation Class H,Dry type air filter with low vibration and noise ) including construction of bed earthing and all necessary connections |
| 384 | HANDLING OF STORE ITEMS |
| 385 | Unloading of Steel Tubular Pole including carriage upto stacking site (16 m long ) upto distance of 50 mtr. |
| 386 | Unloading of Steel Tubular Pole including carriage upto stacking site (13 m long ) upto distance of 50 mtr. |
| 387 | Unloading of Steel Tubular Pole including carriage upto stacking site (11 m long ) upto distance of 50 mtr) |
| 388 | Unloading of Steel Tubular Pole including carriage upto stacking site (09 m long ) upto distance of 50 mtr) |
| 389 | Loading of Steel Tubular Pole including carriage upto loading site (16 m long ) upto distance of 50 mtr. |
| 390 | Loading of Steel Tubular Pole including carriage upto loading site (13 m long ) upto distance of 50 mtr. |
| 391 | Loading of Steel Tubular Pole including carriage upto loading site (11 m long ) upto distance of 50 mtr) |
| 392 | Loading of Steel Tubular Pole including carriage upto loading site (09 m long ) upto distance of 50 mtr) |
| 393 | Unloading of steel of sorts (M.S/G.I channels, angles,TMT iron etc) |
| 394 | Loading of steel of sorts (M.S/G.I channels, angles,TMT iron etc) |
| 395 | Unloading of Conductor reels (100sqmm,150sqmm and 200sqmm) |
| 396 | Loading of Conductor reels (100sqmm,150sqmm and 200sqmm) |
| 397 | Shifting of old /new conductor ACSR conductor at an average distance of 50 mtr. From unloading site to site of stacking and stacked properly and also for making space for other store material and its stacking |
| 398 | Handling and arranging of material in divisional stores ,fabrication of angle iron braces/belts/guard netting angles fencing posts etc. from angle iron of sizes |
| 399 | Fabrication of guy rods complete including turn buckle ,straining screw ,anchor plate threading of guys and staining screw |
| 400 | Fabrication of channels cross arms of sorts from M.S/G.I channels of sizes ,making holes as per requirement,punching of members and numbering on each member ,Grinding of sharp edges and uneven surfaces of members and painting of members with red oxide paint. |
| 401 | Fabrication of ties ,clamps from MS flat (suitable 9m,11m,13m and 16m) |
| 402 | Fabrication of earthing plates ,cable duct covers from M.S plate as per R.E.C drawings |
| 403 | Fabrication of earthing spikes from M.S or steel of sorts as per R.E.C drawings |
| 404 | Fabrication of ST Poles by way of drilling of holes |
| 405 | Fabrication of foundation bolts from M.S /G.I steel of sorts as per REC drawing |
| 406 | Fabrication of earthing pipe from G.I pipe and welding of earthing plate as per REC drawing. |
| 407 | Fabrication of coulumn structure,beam structure ,isolator structures,L.A,C.T,P,T and P.I structures from M.S/G.I. |
| 408 | Manual carriage of M.S/G.I angles/channels/flats from dumping site to fabrication site upto distance of 50mtr. |
| 409 | Manual carriage of M.S/G.I angles/channels/flats from fabrication site to stacking site upto distance of 50mtr. |
| 410 | Unloading of fresh 11 KV VCB Panel (incomer and outgoing ) |
| 411 | Dragging of fresh 11 KV VCB Panel (incomer and outgoing ) from unloading site to stacking site upto distance of 50 mtr. |
| 412 | Unloading of damaged 11 KV VCB Panel (incomer and outgoing ) |
| 413 | Dragging of damaged 11 KV VCB Panel (incomer and outgoing ) from unloading site to stacking site upto distance of 50 mtr. |
| 414 | Loading of fresh 11 KV VCB Panel (incomer and outgoing ) |
| 415 | Unloading of AC Board/DC board/Battery Bank/Battery Charger |
| 416 | Dragging/Manual carriage of AC Board/DC board/Battery Bank/Battery Charger from unloading site to stacking site upto distance of 50 mtr. |
| 417 | Loading of AC Board/DC board/Battery Bank/Battery Charger |
| 418 | Unloading of 33KV CnR Panel |
| 419 | Dragging of 33KV CnR Panel from unloading site to stacking site upto distance of 50 mtr. |
| 420 | Loading of 33KV CnR Panel |
| 421 | Unloading of 33KV CT,PT |
| 422 | Dragging of 33KV CT,PT from unloading site to stacking site upto distance of 50 mtr. |
| 423 | Loading of 33KV CT,PT |
| 424 | Unloading of 33 KV VCB |
| 425 | Dragging of 33 KV VCB from unloading site to stacking site at an avg distance of 50 mtr. |
| 426 | Loading of 33 KV VCB |
| 427 | Unloading of filter plant Heavy Duty |
| 428 | Shifting of filter plant Heavy duty from unloading site to stacking site at an avg distance of 50 mtr. |
| 429 | Unloading of XLPE Cable 120/185 sqmm |
| 430 | Unloading of XLPE Cable 240/300 sqmm |
| 431 | Unloading of XLPE Cable 400/600/630 sqmm |
| 432 | Loading of XLPE Cable 120/185 sqmm |
| 433 | Loading of XLPE Cable 240/300 sqmm |
| 434 | Loading of XLPE Cable 400/600/630 sqmm |
| 435 | Manual carriage of XLPE Cable 120/185 sqmm from unloading site to stacking site upto distance of 50mtr. |
| 436 | Manual carriage of XLPE Cable 240/300 sqmm from unloading site to stacking site upto distance of 50mtr. |
| 437 | Manual carriage of XLPE Cable 400/600/630 sqmm from unloading site to stacking site upto distance of 50mtr. |
| 438 | Shifting of existing old/new XLPE Power Cable from unloading site to proper stacking or rearranging the existing cable to make soace for new material |
| 439 | Unloading of Guy/G.I wire/Barbed wire uncluding carriage towards stacking site and stacking properly |
| 440 | Loading of Guy/G.I wire/Barbed wire uncluding carriage towards stacking site and stacking properly |
| 441 | Un loading of hardware material such as nuts and bolts ,clamps of sorts washers,welding rods chain link mesh,pipe etc |
| 442 | Loading of hardware material such as nuts and bolts ,clamps of sorts washers,welding rods chain link mesh,pipe etc |
| 443 | Unloading of cement |
| 444 | Shifting of cement from unloading site to stackling site |
| 445 | Loading of cement |
| 446 | Unloading of 33/11 KV isolators |
| 447 | Shifting of 33/11 KV isolators from unloading site to stacking site at an average distance of 50 mtr. |
| 448 | Loading of 33/11 KV isolators |
| 449 | Shifting of hardware material such as nuts and bolts ,clamps of sorts washers,welding rods chain link mesh,pipe etc from unloading site to stacking site |
| 450 | Unloading of Guy/G.I/Barbed Wire and carriage upto stacking site |
| 451 | Loading of Guy/G.I/Barbed Wire and carriage upto stacking site |
| 452 | Unloading of 33/11 KV Cable Kits and carriage upto stacking site |
| 453 | Loading of 33/11 KV Cable Kits and carriage upto stacking site |
| 454 | Unloading of 33KV /11KV disc insulator/pin insulator/disc fitting/L.A /PG clamps/T-Clamps/guy insulator/Al.Thimbles/isolator clamps/Tripping coils/Relays/Meters/ |
| 455 | Loading of 33KV /11KV disc insulator/pin insulator/disc fitting/L.A /PG clamps/T-Clamps/guy insulator/Al.Thimbles/isolator clamps/Tripping coils/Relays/Meters/ |
| 456 | Manual carriage of 33KV /11KV disc insulator/pin insulator/disc fitting/L.A /PG clamps/T-Clamps/guy insulator/Al.Thimbles/isolator clamps/Tripping coils/Relays/Meters/ |
| 457 | Unloading of Power transformer 3.15/4 MVA New/Damaged |
| 458 | Unloading of Power transformer 5/6.30 MVA New/Damaged |
| 459 | Unloading of Power transformer 10 MVA New/Damaged |
| 460 | Loading of Power transformer 3.15/4 MVA New/Damaged |
| 461 | Loading of Power transformer 5/6.30 MVA New/Damaged |
| 462 | Loading of Power transformer 10 MVA New/Damaged |
| 463 | Unloading of 11KV New/Damaged Distribution transformer including dragging upto stacking site at an avg distance of 50 mtr. |
| 464 | Loading of 11KV New/Damaged Distribution transformer including dragging upto stacking site at an avg distance of 50 mtr. |
| 465 | Dragging of Power transformer 3.15/4 MVA New/Damaged from unloading site or stacking site as required for loading/stacking upto distance of 100 mtr. |
| 466 | Dragging of Power transformer 5/6.30 MVA New/Damaged from unloading site or stacking site as required for loading/stacking upto distance of 100 mtr. |
| 467 | Dragging of Power transformer 10 MVA New/Damaged from unloading site or stacking site as required for loading/stacking upto distance of 100 mtr. |
| 468 | Unloading of 33 KV/11KV isolators and carriage upto stacking site upto distance of 50 mtr. |
| 469 | Loading of 33 KV/11KV isolators and carriage upto loading site upto distance of 50 mtr. |
| 470 | Unloading of transformer oil including stacking upto stacking site upto distance of 50 mtr |
| 471 | Fabrication ,erection and painting 15 Mtr. Long 33 KV self supporting structure for road/nallah crossing or as per requirement and as per standard drawing Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail