| 1 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 meters lead. 3.2 For thickness of tiles above 25 mm and upto 40 mm. |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as perdirectionofEngineer-in-charge:15.2.1 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming toIS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 4 | Removal of excavated mulba dismantled or unservicable material from the site of work by mechanical transport or animal transport or otherwise including loading/unloading (complete job) |
| 5 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 6 | P/F of Acp sheet board 4mm thick with complete job |
| 7 | P/F of Electrification points with complete job |
| 8 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:18.4.1 One urinal basin with 5 literwhite P.V.C automatic flushing cistern. |
| 9 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Zsections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) |
| 10 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Zsections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)For shutters of doors, windows &ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) |
| 11 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 12 | P/F of waste pipe with complete job |
| 13 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat ofneatcement includingcement slurry andcuringcomplete, but excluding the cost of nosing ofsteps etc. complete |
| 14 | Carriage of materials by mechanical transport including loading / unloading &stacking complete sand for an avg distance of 5 kms |
| 15 | Carriage of materials by mechanical transport including loading / unloading &stacking complete stone aggregate below 40mm nominal size for an average distance of 7 kms. |
| 16 | Labour engaged for desilting,readjustment of manholes covers, diverting the direction of water dewatering during the execution of work and disposal away from site.(2 no for 2 days paid as per actual) |
| 17 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: 20 mm dia. nominal bore |
| 18 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth.8.10.1 White Agaria Marble Stone Please Enable Macros to View BoQ information |