Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation n. exc 30cm deep and averaging 15 cm deep and getting out in Soft/Loose soil complete all as specified & as directed by Engineer-In-Charge. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width and depth or 10 sqm on plan), in any kind of soil including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified & as directed by Engineer-In-Charge. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width and depth or 10 sqm on plan), in ordinary rock including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated ordinary rock an disposal of surplus excavated ordinary rock as directed, within a lead of 50 m complete all as specified & as directed by Engineer-In-Charge. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width and depth or 10 sqm on plan), in hard rock where blasting prohibited including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated hard rock and disposal/ stacked of surplus excavated hard rock as directed, within a lead of 50 m complete all as specified & as directed by Engineer-In-Charge. |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), in any kind of soil. Add for each additional 1.5 m or part thereof in depth beyond the first 1.5 m including dressing of sides and ramming of bottoms, lift upto 2.1 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified & as directed by Engineer-In-Charge. |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), in ordinary rock. Add for each additional 1.5 m or part thereof in depth beyond the first 1.5 m mincluding dressing of sides and ramming of bottoms, lift upto 2.1 m, including getting out the excavated ordinary rock and disposal of surplus excavated ordinary rock as directed, within a lead of 50 m complete all as specified & as directed by Engineer-In-Charge. |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), in hard rock where blasting prohibited. Add for each additional 1.5 m or part thereof in depth beyond the first 1.5 m including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated hard rock and disposal/ stacked of surplus excavated hard rock as directed, within a lead of 50 m complete all as specified & as directed by Engineer-In-Charge. |
| 8 | M & L for PCC (1:4:8) type D-2, using (40mm graded crushed stone aggregate) as in foundataion fiiling & mass concrete complete all as specified & as directed by Engr in Charge. |
| 9 | M & L for M25 reinforced ready mix cement concrete (design mix)in foundation including raft footing,foundation beam,plinth beam,bases of column etc.,basement slab,under reamed piles and mass concrete complete all as specified & as directed by Engineer-In-Charge. |
| 10 | M & L for M25 reinforced ready mix cement concrete (design mix) in Beams, cantilever,lintels, columns,pillars,piers,posts,str-uts chullah hoods,stair case,arches,chajjas,domes,valuts,shell roofs,arch ribs,folded plates,slabs ,balconies,canopies,deck slabs etc.,or in similar articles upto 5 th floors complete all as specified & as directed by Engineer-In-Charge. |
| 11 | M & L for TMT bars (IS ;1786)of strength grade Fe 500D,10mm dia & over cut to length bent to shape required including, cranking binding with & including MS wire not less than 0.90m dia or securing clips complete all as specified & as directed by Engr in Charge. |
| 12 | M & L for TMT barsr (IS ;1786)of strength grade Fe 500D 5 mm dia and over up to and including 10 mm dia ba as in stirrups, spacers & binders etc.complete all as specified & as directed by Engr in Charge. |
| 13 | Supply and fix rolled sections in truss, main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc Fe-410-W (Gde E-250) Quality A complete all as specified & as directed by Engr in Charge.Note :- The contractor shall execute the work as per the drawings provided by the Engr-in-charge. |
| 14 | Supply and fix for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe-410-W (Gde E-250) Quality A complete all as specified & as directed by Engr in Charge. |
| 15 | Supply and fix pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, colour as approved by Garrison Engineer having tensile strength of 550Mpa as in roof covering /cladding to wall fixed with self tapping screws /L hooks or J types or cranked bolts complete all as specified & as directed by Engr in Charge. |
| 16 | Supply and fix pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick, colour as approved by Garrison Engineer having tensile strength of 550Mpa as in ridge, hips, valley gutter, roof covering /cladding to wall fixed with self tapping screws /L hooks or J types or cranked bolts complete all as specified & as directed by Engr in Charge. |
| 17 | Use and Waste for framework to sides of concrete foundation ,footing,bases of columns,rafts,and raft beams,sides and soffits (if any of foundation and plinth beams,and simmilar work,vertical or to batter complete all as specified & as directed by Engr in Charge. |
| 18 | Use and Waste formwork to sides and soffits of beams , lintels,column etc.complete all as specified & as directed by Engr in Charge. |
| 19 | Use and waste of Formwork to edges of concrete flats n.exc. 20cm wide complete all as specified & as directed by Engineer-In-Charge |
| 20 | Use and waste of formwork to chajjas including edges complete all as specified & as directed by Engineer-In-Charge |
| 21 | M&L Ante- Termite to Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & as directed by Engineer-In-Charge |
| 22 | M&L Ante- Termite to Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified & as directed by Engineer-In-ChargeEngr in Charge. |
| 23 | M&L Ante- Termite to Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified & as directed by Engineer-In-Charge. |
| 24 | M&L Ante- Termite to Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & as directed by Engineer-In-Charge |
| 25 | M&L Ante- Termite to Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified & as directed by Engineer-In-Charge. |
| 26 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & as directed by Engineer-In-Charge. |
| 27 | M & L for Hard-core of broken brick not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified & as directed by Engineer-In-Charge. |
| 28 | M&L for 100mm thick PCC (1:4:8) Type D2 using (40mm graded crushed stone aggregate) as in sub base flooring complete all as specified & as directed by Engineer-In-Charge. |
| 29 | M & L 40 mm thick PCC type B-1, (1:2:4) (20mm graded crushed aggregate) as in sub base of flooring complete all as specified & as directed by Engr in Charge. |
| 30 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base 20mm thik in CM(1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & as directed by Engr in Charge. |
| 31 | Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar 10 mm thick backing coat in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & as directed by Engr in Charge. |
| 32 | M & L ,75 MM thick,750mm wide PCC (1:3:6) grade type ,C-1 using (20 mm graded crushed stone aggregate) finished fair and even laid to aslope of 1:20 ,as in plinth protection.inc bituminous joints complete all as specified & as directed by Engineer-In-Charge. |
| 33 | Supply and fix false ceiling with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part4)-1970 and light reflectance of horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized @ 120grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross -T of size 15 x 32mm of length 1200mm and secondary intermediate cross T- of size 15 x 32 mm of length 600mm to form grid module of ceiling using galvanized mild steel items (galvanizing @80grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod as per site requirement and L-shape level adjusting of size 85x 25x 2mm. Galvanised iron perimeter wall angle of size 24x 24x 0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs of 450mm centre to center and 40mm long dry wall wood screws. the work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge with fully perforated 12 mm thick micro tegular edged or 10mm thick square edged GRG false ceiling tiles. complete all as specified & as directed by Engineer-In-Charge.Note :- Design and pattern of Glass reinforced gypsum tiles as approved by Garrison Engineer |
| 34 | Material and labour for brickwork with Old size fly ash' bricks straight or curved on plan exc 6 m mean radius in CM (1:6) complete all as specified & as directed by Engineer-In-Charge. |
| 35 | Material and labour for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified & as directed by Engineer-In-Charge. |
| 36 | Material and labour for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified & as directed by Engineer-In-Charge. |
| 37 | Material and labour for rendering 5 mm thick in CM (1:3) on concrete surfaces of ceiling and finished the surface even and smooth without using extra cement complete all as specified & as directed by Engineer-In-Charge. |
| 38 | Supply only Liquid water proofing compound mixed in mortar (for wall plastering and floor PCC ) and mixed in concrete to increase workability of plaster and concrete.and make structure water proof.complete all as specified & as directed by Engr in Charge. |
| 39 | Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified & as directed by Engineer-In-Charge. |
| 40 | M & L for pressed steel frames for doors with one or more rebates including necessary fixing lungs,hinges,lock strike plate and welding as per requirement etc complete, as specified supplied & fixed (125 x 60mm) complete all as specified & as directed by Engineer-In-Charge. |
| 41 | S & F 2nd class hard wood 35 mm thick Plain framed,factory made panelled shutter (two panels) with lock rail and panel of 9mm BWP comercial ply or 12mm vennered particle board with comercial veneering on both faces. The size of rail & stile as per IS: 1003, klin seasoned & chemically pressure treated.complete all as specified & as directed by Engineer-In-Charge |
| 42 | S&F aluminium powder coated three track sliding window with 5.5 mm thick tinted glass shutters and stainless steel mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clip etc using following aluminium powder coated sections conforming to catalague of ~JINDAL~ or of equivalent may complete all as specified & as directed by Engineer-In-Charge.(a). Bottom frame - 20620, (b) Top frame and vertical -20621, (c) Handle (side) -20606, (d) Shutter interlock -20724, (e) Shutter top and bottom -20844 & (f) Glazing clip -19352. |
| 43 | S & F Aluminium alloy 300 mm long, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed complete all as specified & as directed by Engineer-In-Charge. |
| 44 | S & F Aluminium handles 125 mm long, cast type, anodised complete all as specified & as directed by Engineer-In-Charge. |
| 45 | S & F Aluminium anodised, barrel tower bolts 150 mm long of extruded section and fixed complete all as specified & as directed by Engineer-In-Charge. |
| 46 | Supply and fixed Butt hinges,100 mm size ,heavy weight with mild steel hinge pin, bright polished and fixed complete all as specified & as directed by Engineer-In-Charge. |
| 47 | M & L for providing cement concrete in copings type B1 (1:2:4)) (using 20mm graded stone aggregate) including necessary formwork complete all as specified & as directed by Engineer-In-Charge. |
| 48 | M & L for Cement concrete in surface channels and drains avg 50 mm thick type B0 1:2:4, using 12.5mm aggregate complete all as specified & as directed by Engineer-In-Charge. |
| 49 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard ,pipes,bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165.complete all as specified & as directed by Engineer-In-Charge. |
| 50 | M & L for preparation of new wooden surfaces of any description exc 10cm width or girth & aplying two coats of synthtic enamel paint (1st grade quality) over one coat of pink primer complete all as specified & as directed by Engr in Charge. |
| 51 | M & L preparation of new steel surfaces of any description ,primming with red oxide zink chrome exc 10cm width or girth & aplying two coats of synthtic enamel paint (1st grade quality) ,complete all as specified & as directed by Engr in Charge. |
| 52 | Material and labour for preparation of newly plastered surfaces of walls Providing and applying wall care putty of total 1.5 mm thick in two layers over plastered surface to prepare the surface even and smooth, and applying two coats of acrylic emulsion distemper over and including a coat of primer complete all as specified & as directed by Engineer-In-Charge. |
| 53 | Material and labour for preparation of newly plastered surfaces of walls and Providing and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over plastered surfaces complete all as specified & as directed by Engineer-In-Charge. |
| 54 | Material and labour newly plastered surfaces of ceilings and Providing and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over plastered surfaces complete all as specified & as directed by Engineer-In-Charge. |
| 55 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in (Soft / loose soil) complete all as specified & as directed by Engr in Charge. |
| 56 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in (Soft / disintegrated rock )complete all as specified & as directed by Engr in Charge. |
| 57 | Removing excavated of Soil mtrl n.exc.50 Mtr & depositing where directed at a level n.exc.1.5Mtr above the starting point.complete all as specified directed by Engr in Charge. |
| 58 | M&L for providing and laying 60mm thick factory made chamfered edge rubber moulded glazed (glossy finished) precast cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawn, drive way or light traffic parking etc of required strength , thickness & size/ shape and confirming to IS 15658-2006 made by table vibratory method using PU mould , laid in required colour & pattern over & including 25mm thick compacted bed of crushed stone sand, compacting and proper embedding/laying of interlocking paver block into sand bedding layer through vibratory compaction by using plate vibrator , filling the joints with sand and cutting of paver block as per required size and pattern , finishing and sweeping extra sand complete all as specified & as directed by Engineer-In-Charge. |
| 59 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement: 3 coarse sand), including making joints with or without grooves\ (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete all as specified & as directed by Engineer-In-Charge. |
| 60 | M&L for point wiring (Concealed wiring) of any length using approved colour coding as per IE rule, with multi stranded copper conductor 1.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLSH cable 1100 volts grade, in and including PVC rigid conduits heavy duty, medium grade, ISI marked (Min 20mm dia ) with valid CML No. totally concealed in wall/floor and casing capping /conduits along roof /false ceiling including all accessories as required complete including GI Metal Flush boxes (min 0.8 mm thick) with modular frame/cover plate of suitable size for mounting modular switches/sockets etc. and PVC insulated multi stranded FRLSH copper conductor 1.5 Sqmm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by E in Charge for the following:- |
| 61 | One light point controlled by one switch one way type |
| 62 | One Ceiling fan/Exhaust fan point controlled by one switch one way type |
| 63 | One 3 pin 5 Amps socket outlet point on Same board |
| 64 | One 3 pin 5 Amps socket outlet point on independent board |
| 65 | Notes for Item Sr No 60.01 to 60.04 -(i) Cutting in chases and pointing in brick wall/Stone Wall will be done by contractor without any extra cost.(iI) Contractor shall provide circuit wiring with 3 x 2.5 Sqmm copper wire from DB to switch board and rate for the same is deemed to be included in unit rate quoated by the contractor. |
| 66 | All as per item No. 60 above but with 2.5 sq mm copper conductor FRLSH (multistrand), 1100 volts grade PVC insulated, ISI marked unsheathed cable in and including concealed PVC conduit, heavy duty, ISI marked, medium grade with valid CML No. not less than 25 mm dia with all fitting & accessories as required and including PVC insulated ISI marked, unseathed, FRLSH copper conductor cable of size 2.5 sq mm (Green Colour) as earth wire to common earth dolly complete all as specified & as directed by Engr in Charge. for one three pin socket outlet 15 Amps. |
| 67 | All as per item No. 60 above but with 4.0 sq mm copper conductor, FRLSH (multistrand), 1100 volts grade, PVC insulated ISI marked, unsheathed cable in and including concealed PVC conduit, heavy duty ,ISI marked, medium grade with valid CML No not less than 25 mm dia with all fitting & accessories as required and including PVC insulated ISI marked, unsheathed FRLSH copper conductor cable of size 4.0 sq mm (Green Colour) as earth wire to common earth dolly complete all as specified & as directed by Engr in Charge. |
| 68 | Supply and fix modular switch, one way, 6 Amps, one module (ISI Marked) ccomplete all as specified & as directed by Engr in Charge. |
| 69 | Supply and fix modular socket 6 Amps 2/3 pin, two module complete all as specified & as directed by Engr in Charge. |
| 70 | Supply and fix modular switch, one way, 16 Amps, one module (ISI Marked) complete all as specified & as directed by Engr in Charge. |
| 71 | Supply and fix modular socket 6 Amps /16 Amps 2/3 pin two module (ISI Marked) ccomplete all as specified & as directed by Engr in Charge. |
| 72 | S & F 240 V, Single pole and neutral enclosure with a two pin and earth plug and socket IK08, Conforming to IEC-61439-3 complete with one 20 Amp single pole MCB C curve, 10 KA, including metal plug top (2P+E) ccomplete all as specified & as directed by Engr in Charge. |
| 73 | Supply and fix ceiling rose, 3 terminals / PVC / Polycarbonate, isolated body (ISI Marked) complete all as specified & as directed by Engr in Charge. |
| 74 | S & F LED Tube light fitting 22 watt, surface / wall mounted LED batten housing made of aluminium extrusion with high efficient LED`s, opal diffuser, IP 20, with system efficacy of 100 lm/W , colour temp 6500 K, 50 Hz, 240 V complete including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to connector of light fittings, incl 2 x PVC mounting box for fixing of light complete all as specified & as directed by Engr in Charge.Make - Halonix Cat Part No- HLB-03-22-CW-AL-SQ or equivalent in Luker - LUMOS PRIMO Aluminium tube set-LTA-522 , or equivalent Crompton, Cat Part No: CCS-103-22-65-SLDP-NWH. |
| 75 | S & F Recess mounted LED Panel light 40 W LED of size 600mm x 600MM x 35mm, 240Volts, colour temp 6500 K with glare free symmetrical illumination suitable for ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with three core wire, all acessories as required for fixing the light fitting and matching to the adjacent ceiling surfacescomplete all as specified & as directed by Engr in Charge.Make - Luker Model No LKM2240N or Halonix Cat Part No RADIANCE OPAL, HLFPR22-27-40-CW-HL-2 or equivalent in Crompton, Cat Part No: POLARIS, TCR-145-40-65-SL-NWH |
| 76 | S&F LED Security light fittings with sensor of 70/72 Watt with PDC housing, IP 66 complete with all accessories such as MS Clamp, nut, bolts, GI mounting bracket of min. 40mm dia & length upto 1.5 mtr etc. prewired, connecting light fitting to light source with three core wire sheathed copper wire of 1 sqmm in flexible pipe complete all as specified & as directed by Engr in Charge.Make - Luker - LST072 WH SENSOR (STRADA Street Light) or equivalent in Halonix (Cat Part No: HLSLD-01-72-CWDL-R-S) or equivalent in Havells Cat Part No: ENDURA SUNBEAM SL70WLED 757 SASYTO-PCSENSO. |
| 77 | Supply and fixing BLDC ceiling fans 1200 mm sweep confirming to BIS 374-2019 (upto latest amendment) complete with blades, down rod of adequate length (of suitable length so that distance between floor and bottom of ceiling fan should be 280 cm) with accessories like canopy, nut bolts, shanks and shackle etc, 230 V, Single Phase, 50 Hz, AC, suitable to operate with input voltage 120 V to 300 Volt, PF min 0.90, double ball bearing, 1200 mm sweep, min air delivery 210 Cubic meter per minute (CMM), 28 watt, Min 350 RPM, Insulation class \\"B\\", White colour, Min 4 years OEM warranty, min service value - 6.00, BEE Five star rated (valid 5 Star rated, BIS/BEE Certification as on date of installation) with brushless direct current motor (BLDC), white colour complete including Modular type fan regulator 2 Module and making electric connection by providing 1.0 Sqmm x 3 core flexible sheathed copper cable from ceiling rose/ source to fan connector in flexible pipe. complete all as specified & as directed by Engr in Charge.Note - (i) Contractor shall submit the technical specification, tech data sheet of BLDC fan, valid BEE - 5 star certification during the date of commencement of contract and take approval of GE before procurement.(ii) Contractor shall submit the on site warranty certificate of OEM for 4 years from date of completion of work and submit the purchase voucher before claiming payment. |
| 78 | S & F exhaust fan made of ABS (Acrylonitrile Butadiene Styrene) plastic or high-grade thermoplastic of sweep 300 mm with louver, single phase suitable for 230 volts, 50 HZ, min 1000 rpm and copper winding min air deilvery 1125 CMH and connecting up complete including making electric connection by providing 1.0 Sqmm x 3 core flexible sheathed copper cable from ceiling rose to connector of fan including providing all accessories and PVC hard board base/ Ply wood not less than 10 mm thickness of suitable size for mounting/ fixing of exhaust fan on existing wooden/ aluminium frame window / ventilator complete all as specified & as directed by Engr in ChargeNote - (i) Contractor shall submit the tech data sheet of fan and take approval of GE before procurment. (ii) Contractor shall submit the on site warranty certificate of OEM for 02 years from date of completion of work and submit the purchase voucher before claiming payment. |
| 79 | S&F MCB SP 6 to 32 Amps 240V, 10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified & as directed by Engr in Charge. |
| 80 | M&L for Sub main wiring with threesingle core PVC insulated unsheathed cable 1100 volts grade, 10.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in and including through concealed conduit, including PVC conduit medium grade, heavy duty, ISI marked not less than 25 mm dia (size of conduit shall be according to max numbers of wires permissible to be drawn as per IE rule), in any type of wall/floor, etc, with all connected fittings, including PVC insulated unsheathed 10.0 Sqmm FRLSH cable with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after complete all as specified & as directed by Engr in Charge.Note- (i) Making good of distrubed surfaces matching with existing finishes shall be done by contractor without any extra cost to department. (ii) Three runs of 10 Sqmm cable with 01 run of 10 Sqmm earth wire along with PVC conduit shall be measured as one RM. |
| 81 | M&L for concealed Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including through concealed conduit, including PVC conduit medium grade, heavy duty, ISI marked not less than 25 mm dia (size of conduit shall be according to max numbers of wires permissible to be drawn as per IE rule), in any type of wall/floor, etc, with all connected fittings, including PVC insulated unsheathed 4.0 Sqmm FRLSH cable with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after complete all as specified & as directed by Engr in Charge.Note- (i) Cutting in chases and pointing in brick wall/Stone Wall /beam or any type of surface for concealing the conduit shall be done by contractor without any extra cost.(ii) Making good of distrubed surfaces matching with existing finishes shall be done by contractor without any extra cost to department. (iii) Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with PVC conduit shall be measured as one RM.(iv) Contractor shall provide wire mess on chase cutting for laying of conduit in concealed before plastering to avoid development of crack on surface without any extra cost. |
| 82 | Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cable in underground and getting out complete all as specified & as directed by Engr in Charge for following types of soil |
| 83 | Soft/ Loose Soil |
| 84 | Hard/Dense soil |
| 85 | Supply and laying of 40 mm outer dia, double walled corrugated DWC pipe conforming to IS- 16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings such as couplers/ connectors etc. for cable protection complete all as specified & as directed by Engr in Charge. (for 25 Sqmm x 4.0 Core and 10 sqmm x 4.0 Core XLPE UG Cables) |
| 86 | Supply and laying of 75 mm outer dia, double walled corrugated DWC pipe conforming to IS- 16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings such as couplers/ connectors etc. for cable protection complete all as specified & as directed by Engr in Charge. (for 50 Sqmm 3.5 Core XLPE UG Cables) |
| 87 | Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC sheathed, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm x 3.5 core, ISI marked, conforming to relevant IS, heavy duty including connecting the cables at both ends by providing suitable size cable glands, aluminium lugs at the termination ends all as specified and directed by Engg-In-charge. Cable to be laid in trenches/ducts/under plinth floors passing through pipes etc. or fixed on wall by providing clamps complete all as specified and directed by engineer in charge.(From existing Feeder Pillar Panel to LT Panel near Simulator Building) |
| 88 | Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC sheathed, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm x 4 core, ISI marked, conforming to relevant IS, heavy duty including connecting the cables at both ends by providing suitable size cable glands, aluminium lugs at the termination ends all as specified and directed by Engg-In-charge. Cable to be laid in trenches/ducts/under plinth floors passing through pipes etc. or fixed on wall by providing clamps complete all as specified and directed by engineer in charge. (from Building Feeder pillar to VTPN DB ) |
| 89 | Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC sheathed, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm x 4 core, ISI marked, conforming to relevant IS, heavy duty including connecting the cables at both ends by providing suitable size cable glands, aluminium lugs at the termination ends all as specified and directed by Engg-In-charge. Cable to be laid in trenches/ducts/under plinth floors passing through pipes etc. or fixed on wall by providing clamps complete all as specified and directed by engineer in charge. (For Voltage Stabiliser) |
| 90 | Supply and installation weather, dust and vermin proof Feeder Pillar box (Cubicle Panel) factory made outdoor type of 3.15 thickness of min size 700 x 500 x 300 mm to accommodate MCCB 4 pole , upto 100 Amps rating - 01 No, IP 54, front openable type, with locking arrangement, powder coated mounted on MS angle iron frame of size 40 x 40 x 6 mm welded in shape, painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary grouting in PCC (1:3:6) type C - 1 using (20 mm graded crushed coarse stone aggregate) complete with leg 45 cm grouted in PCC and 100 cm above ground including making all electrical connection with glands, lugs etc. complete all as specified & as directed by Engr in Charge. |
| 91 | Design Fabricating supply and errecting connecting and testing totally enclosed design verified LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100 mm all arround ,separate compartment for each control gear,cable alley, provision of knock out type plates for various sizes of cables in and out , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15 mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Angle iron frame of 50 x50 x6 mm duly painted and embeded in PCC 1:3:6 45 CM below ground level and 45 Cm above ground level and consisting of following; complete all as specified & as directed by Engr in Charge. (Near Simulator Building ) |
| 92 | Bus bar Chamber : Electrically grade Bus bar aluminium of capacity 160 Amps incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic,non combustible,track resistant high strength FRP insulators for phases and neutral set of 4 for RYB &N -01 set |
| 93 | Incoming(a) MCCB Four Pole 415 Volts 50 Hz 100Amps rupturing capacity of 25 KA ,Ics=100% of Icu , with thermal magnetic protection system, thermal adjustable, protection against overload/shortcircuits, inbuilt instantaneous proctection, Over temperature alarm indication, integrated contact module for status indication - 01 No.(b) Multifunctional Meter to read V,A,HZ etc -01 No(c) Indicator LED Type for RYB set of 3 - 01 setOutgoing- (i) MCCB Four Pole 415 Volts 50 Hz 63 Amps 16KA ,Ics=100% of Icu with thermal magnetic protection system, thermal adjustable, protection against overload/shortcircuits, inbuilt instantaneous proctection, Over temperature alarm indication, integrated contact module for status indication - 02 No ( for VTPN DB - 02 Nos )(ii) MCCB Four Pole 415 Volts 50 Hz 25 Amps 16KA ,Ics=100% of Icu with thermal magnetic protection system, thermal adjustable, protection against overload/shortcircuits, inbuilt instantaneous proctection, Over temperature alarm indication, integrated contact module for status indication - 02 No ( for Voltage Stabiliser - 01 No and Spare - 01 No ) |
| 94 | Note:- (i) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel.(ii) Cost of lugs for cable and cable gland etc also included in unit rate of panel.(iii) Rotary handle to be provided for all MCCB for control and operation of MCCB. (iv) The copper extension link from bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders. (v) Spreader terminals and Phase barriers to be provided with all MCCB`s |
| 95 | S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door with MCCB as incomer (Suitable for mounting upto 100 Amp MCCB) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp fully insulated copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, reversible door provision, blanking plates and circuit identification labels, including flushing and fixing DB box neatly in wall / solid block wall including copper lugs/thimbles duly crimped for connection complete all as specified & as directed by Engr in Charge. |
| 96 | S&F MCCB 100 Amp with Thermal - magnetic release of 63 - 100 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting as per IS-13947 & IEC 60947-2 including all accessories like spreader terminals and face barriers including making all electrical connections by providing lugs of suitable size lugs including Fixing of MCCB in feeder pillar box complete all as specified & as directed by Engr in Charge. |
| 97 | S&F MCCB 100Amp with Thermal - magnetic release of 63 - 100 Amps, 3 Pole, 415V, 16 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting as per IS-13947 & IEC 60947-2 including all accessories like spreader terminals and face barriers including making all electrical connections by providing lugs of suitable size lugs including Fixing of MCCB in VTPN DB box ccomplete all as specified & as directed by Engr in Charge. |
| 98 | Note for Item No 85,86 &87: MCCB, MCB and DB box should be of same make. |
| 99 | Supply,fixing, installation, commissioning and testing Servo controlled Voltage stablizer for automatic operation of 10KVA capacity confiriming to BIS 9815: Part 1 : 1994 reaffirmed 2009, 3 Phase, 50 HZ, Naturally oil cooled, Indoor type, unbalanced type, copper wound, with digital display type Relay, free smooth and silent operation with 1st fill of tramsformer oil (IS335:1993, reaffirmed 2005), IP 42 designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second having following specification complete all as specified & as directed by Engr in Charge.Contd ...(i) Input Voltage 300 Volt - 480Volt.(ii) Output voltage stabilized at 415 V + 1%(Adjustable).(iii) Rated frequency 50 HZ.(iv) No distortion wave form.(v) Respond time shall not to exceed 10 Milisecond.(vi) Sensitivity (+ ) 1 %.(vii) Rate of correction 8 Voilt /Second for single Phase and 20 Volt / Second for Phase to Phase.(viii) No load losses less than 0.5% and full load losses less than 2.5%.(ix) Duty cycle Continuous 24 x7.(x) Efficiency more than 95%.(xi) Type of load : 3 Phase, unbalance type.(xii) Digital Volt meter/Ampere meter.Protection : (i) Overload/ Short circuit protection.(ii) High /Low voltage cut off.(iii) By pass arrangement in case of emergency.(iv) Single Phase preventor and sequence change protection.(v) Voltage stabiliser should be min 2 years OEM on site warranty.Note: \\"Contractor shall submit the technical specification of Servo Control Voltage Stabilizer and take the approval of GE before procurement\\". |
| 100 | S & F 415 V, Three pole and neutral enclosure IK08 Conforming to IEC-61439-3 with a three pin and earth plug and socket complete and suitable for mounting one 32 Amp 4 Pole RCBO (3P + E), including metal plug top (3P+E) complete all as specified & as directed by Engr in Charge.Note : Cost of RCBO shall be paid seprately under relevant item. |
| 101 | S&F RCBO of 32 Amps, 4 Pole, 415V, 30mA, all as per IS-12640-2 , integrated label holder, ergonomic design, color coded on / off indication, compatible with signal and control auxiliaries, front face indication for earth leakage fault, IP 20 protected terminals and sliding shutters, conforming to IEC 60947 including all accessories like spreader terminals and face barriers including making all electrical connections by providing lugs of suitable size lugs including Fixing of RCBOs in metal plug and socket DB box ccomplete all as specified & as directed by Engr in Charge. |
| 102 | Supply, installation and testing of Chemical Earthing complete with copper rod electrode of 17.2 mm dia, 3 mtr length with top copper terminal of size 100 x 50 x 5 mm placed under the ground below GL after drilling bore of 100 mm dia up to 3.5 mtrs depth in any type of soil / disintergated rock/ rocky strata any type and filling of BFC Compound having very high eletrical conductivity, moisture retaining capacity, hygroscopic, non-corrosive in nature and ROHS compliant, in slurry form all round the electrode in bore hole up to the top level. The earth pit shall be covered by providing Reinforced FRP square earth pit cover of size 300 x 300 x 240 mm and capable of carrying weight of 5 tons including making all connections with earth continuity conductor strip by providing brass nut bolted up to the test point complete all as specified & as directed by Engr in Charge. including testing on completion of earthing. (for Simulator)Note: (i) Copper strip of size 20 x 3 mm up to 7.5 mtr length included in unit rate. (ii) Copper strip strip will be laid below 20 cm from ground level and connecting the test point through plinth protection using HDPE pipe for protection, necessary cost of repair to plinth protection and welding/ providing brass nut bolt deemed to be included in the item.(iii) Contarctor shall submit the test report of earthing after satisfactorily completion.(iv) Contractor shall submit the complete literature and specifcation of earthing and shall take approval of GE before procurement of material and execution of job.(iv) Contractor shall submit the NBL lab test certificate of Chemical back fill compound, CPRI certificate of copper electrode for taking approval of make of Chemical earthing. |
| 103 | M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground in bore of size 100 mm dia , x 3 mtr depth in any type of soil / disintergated rock/ rocky strata any type and connected with earthing lead of GI Strip of 25 x 4 mm galvanised iron strip all as shown in Plate No. 2 to the earthing test point complete all as specified & as directed by Engr in Charge. indicated including testing on completion ( For voltage stabilizer - 02, 2 x LT Panels -04 Nos ) including Earth pit & Funnel Pipe. Note: (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg)/transformer/LT kiosk/HT lightening arrestors etc. including GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note :- Earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor and nothing extra on this account is admissible. |
| 104 | M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground in bore of size 100 mm dia , x 3 mtr depth in any type of soil / disintergated rock/ rocky strata any type connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test pointcomplete all as specified & as directed by Engr in Charge. including testing on completion ( for VTDBN -02 Nos ) including Earth pit & Funnel Pipe.Note: (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg)/transformer/LT kiosk/HT lightening arrestors etc. including GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note :- Earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor and nothing extra on this account is admissible. |
| 105 | Material and labour for Gl earth strip 25 x 4 mm as main earth lead on insulator or buried in ground/Wall/ ceiling etc,complete all as specified & as directed by Engr in Charge. (Earth strip beyond 7.50 m in earthing shall be measured under this item) |
| 106 | M&L for laying 40 mm bore GI pipe, light grade, ISI marked, conf to relevant IS with all fittings, in crossing road/path and in pole/wall up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge. |
| 107 | Material and labour for Copper earth strip 20 x 3 mm as main earthing lead fixed on \\"V\\" type porcelain insulator ( ceramic insulator off white colour of min width 36 mm) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles/ wall / ceiling or any other indicated situation for loop earthing etc. complete all as specified & as directed by Engr in Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail