| 1 | General servicing of DG set including cleaning of machines, fuel tank including accoustic encosure etc checking of oil levels, filters, fan belts, hose pipe, proper adjustment of tappet, checking of governor assembly, radiator complete all as per manufacturers recommendations etc complete as per direction of Engr-in-Charge.Note :- Fuel filter, oil filter,Engine oil & Coolant wii be measured and paid separately under subsequent items |
| 2 | 160 KVA ( Make - Crompton Greaves / Mahindra & Mahindra) |
| 3 | 125 KVA ( Make Crompton Greaves ) |
| 4 | 100 KVA ( Make- Kirloskar / Mahindra & Mahindra / Ashok Leyand ) |
| 5 | 70 / 75/82.5 KVA ( Make- Cummins / Kirloskar ) |
| 6 | 58.5/62.5 / 63 KVA ( Make- Ruston / Kirloskar / Greaves / Mahindra / Ashok Leyand / Sudhir / CG ) |
| 7 | 40 KVA ( Make Kirloskar ) |
| 8 | 15/30/32 KVA ( Make- Ruston / Kirloskar / Greaves / Mahindra / Ashok Leyand / Sudhir / CG ) |
| 9 | Repairs to DG set engine of capacity 58.5 to 82.5 KVA any make, 6 cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction and testing of efficiency of engine on completion complete all as directed. (worn out / unserviceable parts shall be measured and paid seperately) |
| 10 | Piston assy as per existing model complete all as directed |
| 11 | Ring set as per existing model complete all as directed. |
| 12 | Cylinder liner as per existing model complete all as directed |
| 13 | Set of liner 'O' ring as per existing model complete all as directed |
| 14 | Gasket set kit as per existing model complete all as directed |
| 15 | Coupling as per existing model complete all as directed |
| 16 | Gasket (Main Seal) as per existing model complete all as directed |
| 17 | Diesel Pipe Set as per existing model complete all as directed |
| 18 | Hose Pipe as per existing model complete all as directed |
| 19 | Hose Clamp as per existing model complete all as directed |
| 20 | Cylinder head gasket as per existing model complete all as directed |
| 21 | Cylinder head 'O' Ring as per existing model complete all as directed |
| 22 | Valve set as per existing model complete all as directed |
| 23 | Valve seal as per existing model complete all as directed |
| 24 | Valve guide as per existing model complete all as directed |
| 25 | Connecting rod bearing as per existing model complete all as directed |
| 26 | Connecting rod bush as per existing model complete all as directed |
| 27 | Fan Belt as per existing model & size complete all as directed |
| 28 | Taking out FIP from DG set, transportation to authorized service centre for overhauling and re-caliberation and re-fixing to DG set complete all as specified and directed of capacity DG Set 100 to160 KVA Make - Crompton Greaves / Mahindra & Mahindra complete all as directed:-(Unserviceable / defective parts shall be measured and paid seperately) |
| 29 | Injector as per existing model complete all as directed |
| 30 | Injector Nozzle as per existing model complete all as directed |
| 31 | Delivery valve as per existing model complete all as directed |
| 32 | FIP Element as per existing model complete all as directed |
| 33 | Gevernor as per existing model complete all as directed |
| 34 | M &L for Taking out FIP from DG set, transportation to authorized service centre for overhauling and re-caliberation and re-fixing to DG set complete all as specified and directed of capacity DG Set 58.5 to82.5KVA Make - Crompton Greaves / Mahindra & Mahindra complete all as directed:-(Unserviceable / defective parts shall be measured and paid seperately) |
| 35 | Injector as per existing model complete all as directed |
| 36 | Injector Nozzle as per existing model complete all as directed |
| 37 | Delivery valve as per existing model complete all as directed |
| 38 | FIP Element as per existing model complete all as directed |
| 39 | Gevernor as per existing model complete all as directed |
| 40 | M & L for Replacement of defective / unserviceable automatic voltage regulator (AVR) suitable for 63 KVA to 160 KVA DG Set complete all as directed. |
| 41 | M & L for Replacement of defective / unserviceable automatic voltage regulator (AVR) suitable for 30 to 40 KVA DG Set complete all as directed. |
| 42 | M & L for Replacement of defective / unserviceable Alternator Dynamo 12 volt 30 to 63 KVA DG Set, as per existing model complete all as directed |
| 43 | M & L for Replacement of defective / unserviceable Stop Solenoid any make, type and capacity as per existing model complete all as directed |
| 44 | M & L for Strip opening of alternator of any capacity and removing rotor from the stator and rewinding to CT coils complete with super enamel copper winding wire of appropriate size including insulating material and replacing Rear and front bearing including greasing of the alternator and refixing with engine and complete testing and refixing all components of the alternator and mounting the same on the existing foundation including aligning the alternator with engine and testing on full load as specified in particular specification and as directed |
| 45 | LED security light 25 W with pressure die-cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 protection including GI Bracket suitable for security light fittings as per required dia length not exceeding 30cm long all as specified and directed by the Engr-in-Charge. |
| 46 | S & F Aluminium strip 25 x 3.15 mm supported on insulated including porcelain insulators for mounting of strips, saddles, stand off hold fast, fixing screws, rawl plug etc for roof and down conductors above ground level complete all as specified. |
| 47 | Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 25x4mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipments all as specified and indicated complete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick) and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engr-In-Charge. |
| 48 | M & L for Replacement of defective / unserviceable self starter for 63 / 62.5 KVA DG Set as per existing model complete all as specified and directed |
| 49 | M & L for Replacement of defective / unserviceable self starter for 100 KVA DG Set as per existing model complete all as specified and directed |
| 50 | M & L forReplacement of defective / unserviceable self starter for 30 / 32 / 40 KVA DG Set as per existing model complete all as specified and directed |
| 51 | M & L for Cleaning of radiator with the help of descaling agent/solution including repairs to the broken tubes and replacement of wornout rubber hoses for 15 to 82.5 KVA DG Set complete all as directed |
| 52 | All as per item no 16 above but of capacity 10 to 160 KVA |
| 53 | M&L for Replacement of defective / unserviceable Air Filter for following capacity DG set of any and model complete all as specified and directed |
| 54 | 10 KVA to 82.5 KVA KVA ( Make - Crompton Greaves / Mahindra & Mahindra) |
| 55 | 100 KVA TO 160 KVA ( Make Crompton Greaves ) |
| 56 | M &L for Replacement of defective / unserviceable Engine Oil 20 W 40 or equivalent grade suitable for DG set at various locations. Make: Castrol/ Servo |
| 57 | Supply and filling concentrated coolant for radiator in 5 litre capacity container complete all as directed, |
| 58 | S & F the battery of 12 V 180 AH suitable for DG set Make : Exide/ Amaron. |
| 59 | S & F the battery of 12 V 90 AH suitable for DG set Make : Exide/ Amaron. |
| 60 | M & L for Replacement of defective / unserviceable battery lead of copper conductor 35 sqmm, 3 mtr length, single core fitted with lead terminal on one side and other side with brass or lead terminal as per requirement and connection as directed |
| 61 | M & L for Replacement of On Load Changeover switch 3 Phase, 415 volts 400 Amps, type C-line in SS Enclosure including fixing arrangement on wall/ floor, including connection,complete all as specified and directed.. Make: Legrand/ Schneider. |
| 62 | M & L for Replacement of On Load Changeover switch 3 Phase, 415 volts 200 Amps, type C-line in SS Enclosure including fixing arrangement on wall/ floor, including connection,complete all as specified and directed.. Make: Legrand/ Schneider. |
| 63 | supply and fix electrical battery charger 24 volt 10 Amp complete all as specified and directed. |
| 64 | supply and fix distilled water complete all as specified and directed. |
| 65 | M & L for Replacement of defective / unserviceable self starter for 125/160 KVA DG Set as per existing model complete all as specified and directed |
| 66 | M & L for Isolate/de-energize the supply to the AMF Panel of different rating capacities, 415 Volts/230 Volts, opening the doors/covers of the AMF panel for carrying out the servicing/maintenance/repairs of the AMF,controler, switch gear, metering including carrying controle wiring with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers, relay's, complete all as specified and directed etc and re-fixing the same in place after repairs including testing and commissioning of the panel board :-(i) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower and apply insulating varnish.(ii) Check the condition of the insulators including cleaning for and replacement of insulators if required. (iii) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required. |
| 67 | M& L for taking out unsv /non working controler unit of SG set insttaled in AMF panel and S & F new contoler unit as per existing make /model installed at DG set of any capcity/make all as specified and directed |
| 68 | M&L for repair of complete rusted /damaged portion of acoustic enclosure by replacing the ms sheet , change of hinges ,door locks , door catch and prepare the surface of DG set and M &L for spray painting with machines with one quote of synthetic enamel paint matching to exisitng colour duly scraping out old rusted surfaces complete all as specified and directed. |
| 69 | Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core including laid in trench up to 50cm in orange HDPE Pipe of size 50mm of dia all as specified and directed . |
| 70 | Al as per item no 32 but of size 70sq mm 3.5 core. |
| 71 | Al as per item no 32 but of size 50sq mm 3.5 core. |
| 72 | Al as per item no 32 but of size 35sq mm 3.5 core. |
| 73 | Al as per item no 32 but of size 25sq mm 3.5 core. |
| 74 | S & F In replacement Alluminium thimble for cable of size 25 to 70Sqmm |
| 75 | S & F In replacement Alluminium thimble for cable of size 95 to150Sqmm |
| 76 | S & F In replacement Alluminium thimble for cable of size 250 to 300Sqmm |
| 77 | S & F in replacement MCCB 3 pole 415 volts adjustable type 160 Amps ,16 KA |
| 78 | S & F in replacement MCCB 3 pole 415 volts adjustable type 250 Amps ,36 KA |
| 79 | S & F in replacement MCCB 3 pole 415 volts adjustable type 125 Amps ,16 KA |
| 80 | S & F in replacement MCCB 3 pole 415 volts adjustable type 400 Amps ,50 KA |
| 81 | Supplying, installation, testing and commissioning of Retrofit Emission control device (RECD) on existing diesel generator set of capacity 160 KVA of make M&M/Kirlosker/CG, to reduce emmission level ie N2, HC,CO Pm & smoke (light absorption Co efficient) Conforming to CPCB-IV & GSR 804 EE) dt 03 Nov 2022 the RECD device shall have minimum specified particulate matter copting efficiency of 70% and it shall be approved by CPCB recognized lab. The device shall have no effect on exahust back pressure and there should be no back flow from RECD to engine exhaust system. The device must be tested by CPCB recognised, approved lab. The manufacture must provide written instruction and requirement about use and maintain of RECD system, all as specified. |
| 82 | Supply and fix in replacement of change over switch 200 Amp 415V four pole in sheet enclosure with side handle operation, off load change over complete all as specified and as directed. |
| 83 | Supply and fix in replacement of change over switch 63 Amp 415V four pole in sheet enclosure with side handle operation, off load change over complete all as specified and as directed. |
| 84 | Supply only element diesel filter with gasket suitable for following capacity of DG set dismantled / fixed under Sch item No 1.00 here in above complete all as specified and directed. |
| 85 | 10 KVA TO 82.5 KVA . |
| 86 | 100 KVA TO 160 KVA . |
| 87 | Supply only element Oil filter with gasket suitable for following capacity of DG set dismantled/fixed under Sch tem No 1.00 here in above complete all as specified and directed. |
| 88 | 10 KVA TO 82.5 KVA. |
| 89 | 100 KVA TO 160 KVA. |
| 90 | Taking out all electrical connection and lifting of DG set and keep aside at safe place and demolition of old PCC platfrom of DG set and M & L for costruction of New raised PCC platfrom for DG set 160/100 KVA of size 3.5 mtr x 2.5 Mtr x .45 mtr with brick contruction all round and filling with earth/hardcore(150mm) and top surface finished with PCC 1:2:4 100 MM thick including plastering of brick work with 1:4 cement mortar all as specified and directed. |
| 91 | M& L for disconnection of all electrical connection including earthing from BER DG set ffixed at DG Installation and taking out from DG Room with the help of hydra and transport to MES store yard from any distance for keeping in Safe custody all as specified and directed. |
| 92 | Taking out all electrical connection and lifting of DG set and keep aside at safe place and demolition of old PCC platfrom of DG set and M & L for costruction of New raised PCC platfrom for DG set 63/82.5 KVA of size 3 mtr x 2 Mtr x .45 mtr with brick contruction all round and filling with earth/hardcore(150mm) and top surface finished with PCC 1:2:4 100 MM thick including plastering of brick work with 1:4 cement mortar all as specified and directed. |
| 93 | Note:- The contract sum shall be arrived at after deduction of amount of Sch of credit. Please Enable Macros to View BoQ information |