| 1 | S&F 60mm thick PUF panels in wall with 0.5mm prepainted galvalume sheet on both face/side including all fixing arrangements as in replacement of old unserviceable damaged portion of wall panel including dismantling of puff panels in any description complete all as per specification and as directed by Engr–in–Charge. |
| 2 | S&F 40mm thick PUF false ceiling panels with 0.5mm prepainted galvalume sheet on both face/side including all fixing arrangements as in replacement of old unserviceable damaged portion of ceiling panel including dismantling of puff panels in any descriptioncomplete all as per specification and as directed by Engr–in–Charge. |
| 3 | S&F in repairs door shutters with 60mm thick PUF panel with 0.5mm thick prepainted MS sheet on both side (Colour as approved by GE) including aluminium 200mm tower bolt (2 Nos), aluminium sliding bolt 300mm (01 Nos), including hydraulic door closure No 3 (heavy duty) and handle 02 nos on both faces including chowkhat of angle 60 x 60 x 6mm fixed with 03 Nos (100mm) heavy duty hinges including Taking down Chowkhats or frames with shutters (without taking off shutters from the frames)complete all as specified and directed by Engr-in-Charge. |
| 4 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, for ashlar facings, dressed stonework and precast concrete articles and precast concrete block walling complete all as specified and as directed by by Engr-in-charge. |
| 5 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc |
| 6 | M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, completeType C1 1:3:6 (20mm graded aggregate)Set in cement mortar 1:6 complete all as specified and directed by Engr-in-charge. |
| 7 | M&L Rendering 15mm thick Cement plaster 1:4 on fair faces of brick work or concrete sur faces finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engr-in-charge. |
| 8 | Preparation of new plastered surfaces of walls Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directe |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by by Engr-in-charge. |
| 10 | M&L for Virified Ceramic tiles light shade 8-10 mm thick (square/ ectangular) polished, area of each tiles exceeding 595mm X 595mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to laying over & including 15 mm thick in cement mortar 1:6 screed bed or bedding layer of mortar for laying floor finishes as directed. |
| 11 | Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge. |
| 12 | Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 14 | S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including glass ,necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified |
| 15 | S&F 4.8 mm Sheet glass,ordinary quality and glazing in square n exc 0.5 sq. m in each pane |
| 16 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 17 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 18 | M&L for Beam, tee, angle, channel or flat sections , hollow pipe, tube (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etc |
| 19 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for preparation of new Puff panel steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F in repair 2.8-3 mm thick Polycarbonate sheet fixed to wooden /metal frames with suitable fixing arrangements complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |