| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/l (vide classification of soil item-B) |
| 3 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 4 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 5 | Providing designation 75 A one brick on edge soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 6 | Providing designation 75 A one brick on flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 7 | 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 13 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Suspended floors, roofs, landings, balconies and access platform |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 17 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l.(a) 8mm (TMT,Coil Fe 500)(Only valid for Tata (Tiscon),SAIL,JSPL,Electrosteel Ltd. Bokaro and Vizag(RINL)) |
| 18 | (a) 10mm (TMT,Coil Fe 500) (Only valid for Tata (Tiscon),SAIL,JSPL,Electrosteel Ltd. Bokaro and Vizag(RINL)) |
| 19 | (c) 12mm ( TMT bar Fe 500) (Only valid for Tata (Tiscon),SAIL,JSPL,Electrosteel Ltd. Bokaro and Vizag(RINL)) |
| 20 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 21 | Providing 75 A Brick work in cement mortar ( 1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials , scafolding, raking out joints to 15 mm depth, curing, taxes and royalty ( but excluding the cost of reinforcement) all complete as per building specification and direction of E/l. |
| 22 | Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening,carriage of materials,scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of rienforcement)all complete as per building specification and direction of E/I. |
| 23 | Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm size graded stone chips finished with floating coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l |
| 24 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 25 | Providing 6mm thick cement plaster (1:4) in the ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes, and royalty all complete as per building specification and direction of E/l. |
| 26 | Providing 19 mm thick waterproof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved waterproofing compound including screening, curing with all leads and lifts of water, scaffolding taxes, and royalty all complete as per building specification and direction of E/l. |
| 27 | providing 1.5mm cement punning |
| 28 | supplying fitting and fixing C.A.R.W.D pipe with necessary strips |
| 29 | supplying fitting and fixing fully glazed steel door windows or ventilations of standard rolled |
| 30 | supplying fitting and fixing 20 GUAGE G.C.I Sheet gate fitted MS angle |
| 31 | providing two coat of snow cem |
| 32 | providing primer one coat of red lead paint of approved |
| 33 | providing two coat of painting with synthetic enamel paint |
| 34 | provciding 50mm thick cement concrete flooring (1:2:4) |
| 35 | providing designetion 75A brick work (1:6) in foundation |
| 36 | providing designetion 75A brick work (1:4) in foundation |
| 37 | Supplying, fitting and fixing 40 mm high vitreous white glazed earthen E.W.C of P trap of parry Hindustan or any other approved I.S.S make including supplying and fixing 15 liters C.I mosquito proof low down fluhing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15 mm P.V.C alkathene pipe 45cm .long with brass coupling at both ends and white/black plastic solid state seal and lead of commander cuckoo or other I.S.S.make with hingers or screws etc. painting pipe and cistern etc .with 2coats of approved paints over a coat of red oxide priming ,all complete as per specification and direction of E/I |
| 38 | Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I.150mm dia |
| 39 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 40 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm bend |
| 41 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm |
| 42 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal outer dia Pipes |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal outer dia Pipes |
| 45 | Providing and fixing PTMT grating of approved quality and colour.100 mm nominal dia |
| 46 | Supplying, fitting and fixing vitreous white glazed earthen I.W.C parry Hindustan or any other approved I.S.S make including supplying and fixing 15 liters C.I mosquito proof low down fluhing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15 mm P.V.C alkathene pipe 45cm .long with brass coupling at both ends and white/black plastic solid state seal and lead of commander cuckoo or other I.S.S.make with hingers or screws etc. painting pipe and cistern etc .with 2coats of approved paints over a coat of red oxide priming ,all complete as per specification and direction of E/I |
| 47 | Providing and fixing brass bib cock of approved quality conforming to IS:8931 : |
| 48 | Providing and fixing. Brass/CI Stop cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 49 | Providing and fixing non return valve approvedquality conforming to IS:893115mm nominal bore |
| 50 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS :12701 marked, with cover and suitable locking arrangement and making necessary holesfor inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 51 | Wiring for light point /fan point/ exhaust fan point/ cell bell point, with 1.5 sq. mm FR PVC insulated copper conductor singel core in surface/recessed PVC conduit, with modular type switch, modular plate sutable GI box etc as required Group C |
| 52 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 53 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.2x2.5 Sqmm + 1x2.5 sqmm earth wire |
| 54 | 4x6 Sqmm + 2x6 sqmm earth wire |
| 55 | Supplying and fixing of the following size of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm |
| 56 | Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required.1.24.1 5/6 amps, one way switch |
| 57 | 1.24.4 5/6 amps, 3 pin socket outlet |
| 58 | Installation of exhaust fan up to 450mm sweep in the exisiting opnening, including making the hole t suit the size of the above fan, making good the damge, connection, testing , commissioning etc. as required |
| 59 | Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)8 way, single door |
| 60 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required.6/32, single pole, \\"B\\" series |
| 61 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amp |
| 62 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50HZ, single phase supply etc. complete as required20/22 W LED Tube light |
| 63 | Supply 12\\" dia Metal exhaust fan etc. |
| 64 | Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M |
| 65 | (b) From 51.00 M to 100.00 M |
| 66 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 67 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 68 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top ofbore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm clamp |
| 69 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 70 | Supplying 100 mm dia submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP |
| 71 | Suppy fitting and fixing of stander make starter pannel bord with arrangment of all necssary protection including all taxes, all complet job as per direction E/I |
| 72 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work32 mm nominal dia Pipes |
| 74 | Carriage of material CEMENT |
| 75 | CHIPS |
| 76 | BRICK |
| 77 | ADD GST(18%) |
| 78 | LABOUR CESS Please Enable Macros to View BoQ information |