| 1 | Scraping old white or colour wash including disposal of refuse as directed by E/I as per DSR 13.88 |
| 2 | Racking out joints of brick work in cement or lime mortar to a depth of 1 cm. (3/8'') including disposal of refuse as directed by the Engineer-In- charge within a distance of 60 meters (200Ft).as per DSR 14.17 .Excluding GST |
| 3 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. DSR 14.1.1 |
| 4 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.as DSR no. 13.80 |
| 5 | Finishing walls with Premium Acrylic Smooth exterior paint with Siliconeadditives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqm). as per DSR13.47.1 |
| 6 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture DSR 13.48.2 |
| 7 | First class/class-150 brick work in 1:4 (one cement six fine sand) 1.25 F.M. moudules mortar in foundation and plinth including supply of all materials ,labour, T&P etc. required for proper completion of work. as per SI No. 303 PBH |
| 8 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. as per DSR 10.5.1 |
| 9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR 11.37 |
| 10 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.DSR 11.41A.1.1 Size of Tile 600 x 600 mm |
| 11 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.as DSR 8.31 |
| 12 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.DSR 9.20.1 |
| 13 | S/f 100mm dia P.V.C. down pipe and Sewer pipe including clamp bends etc. complete including supply of all materials, labour T&P etc. required for proper completion of the work.(SOR Chapter ISN. 16(31) |
| 14 | S/f 75 mm dia P.V.C. down pipe and Sewer pipe including clamp bends etc. complete including supply of all materials, labour T&P etc. required for proper completion of the work.(SOR Chapter ISN. 16(31) |
| 15 | Providing and Fixing of C.P. Brass short body bib cock heavy quality including supply of all materials, labour T&P etc. required for proper completion of the work.(S.O.R. Chapter 21 S.No. 44 (PRG) |
| 16 | Providing and Fixing of Angle valve heavy quality including supply of all materials, labour T&P etc. required for proper completion of the work.(S.O.R. Chapter 21 S.No. 44 PRG) |
| 17 | S/F of low level flushing cistern as per SI No. chap2(73) |
| 18 | Providing and fixin bib cock. |
| 19 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizesrespectively.DSR 17.23 |
| 20 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : DSR 17.25.1 Flat back wash basin of size 630x450 mm |
| 21 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 |
| 22 | Providing and laying APP (Atactic lypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black inished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in ongitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 14.91.1 3 add 15% extra. |
| 23 | Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. |
| 24 | Providing & applying a coat of residual petroleum bimen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with space of cloth lightly soaked in kerosene oil 4 13 sqm 113.85 |
| 25 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 26 | 15 mm nominal dia Pipes |
| 27 | 20 mm nominal dia Pipes |
| 28 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not lessthan 10kg/sqm) |
| 29 | Elcetrical work Please Enable Macros to View BoQ information |