| 1 | Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 6 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 7 | Making plinth protection 50 mm thick of cement concrete 1: 3: 6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well ramed and consolidated and grouted with fine sand including finishing the top smooth |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 9 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 11 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 13 | Foundations, footings, walls, bases of columns, etc. for mass concrete. |
| 14 | Shelves (Cast in situ) |
| 15 | Edges of slabs and breaks in floors and walls. |
| 16 | Under 20 cm wide |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 18 | Suspended floors, roofs, landings, balconies and access platform. |
| 19 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 21 | Cold twisted/TMT bars |
| 22 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (at all levels) in all shapes and sizes in: |
| 23 | Cement mortar 1: 6 (1 cement: 6 coarse sand) |
| 24 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 (at all levels) |
| 25 | Cement mortar 1: 4 (1 cement: 4 coarse sand) |
| 26 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 27 | Hot finished welded type tubes |
| 28 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 29 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 30 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 31 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary |
| 32 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : |
| 33 | 35 mm thick shutters (Second Class Deodar wood) |
| 34 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 5mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 35 | Second class deodar wood |
| 36 | 35 mm thick |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete |
| 38 | Fixed to steel windows by welding |
| 39 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 40 | 200x10 mm |
| 41 | 100x10 mm |
| 42 | Providing and fixing aluminium handles ISI marked (powder coated) with necessary screws etc. complete : |
| 43 | 100 mm |
| 44 | 200 mm |
| 45 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 46 | 250x16 mm |
| 47 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete : |
| 48 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 49 | Providing and fixing eye hook |
| 50 | Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design |
| 51 | In 75x75mm deep chase |
| 52 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 53 | 12 mm cement plaster of mix : (Inside) |
| 54 | 1:6 (1 cement: 6 fine sand) |
| 55 | 15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 56 | 1:6 (1 cement: 6 fine sand) |
| 57 | 6 mm cement plaster of mix : |
| 58 | 1:3 (1 cement: 3 fine sand) |
| 59 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 60 | New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 61 | Finishing walls with Acrylic exterior paint of required shade : : |
| 62 | New work (Two or more coat and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 63 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 64 | Two or more coats on new work. |
| 65 | Providing and laying RBM (River Bed Material) including loading, carrying, unloading, spreading, compacting and watering complete item. |
| 66 | Providing and injecting chemical emulsion for pre/post constructional Anti-termite treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor,along the external perimeter of building,expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipe and conduits with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to 1% concentration, labour, HOM of equipments, complete as per specifications.(plinth area of building at ground floor only shall be measured). |
| 67 | Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B) |
| 68 | Single Pole |
| 69 | Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required |
| 70 | 40 amps SPN |
| 71 | Supplying and fixing of suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing of 3 pin 5/6 Ampere modular switch socket outlet including connection testing etc as reqd. |
| 72 | Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required |
| 73 | Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit (2 mm thick) with modular switch, modulr plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 74 | Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required |
| 75 | Supplying and fixing suitable G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 Ampere and 5/6 Ampere modular socket outlet and 15/16 Ampere modular switch, connection testing etc as reqd. |
| 76 | Supply and fixing 1x20 watt LED fitting complete including connection testing etc. as reqd. |
| 77 | Supply and fixing of 18 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL) |
| 78 | Supply and fixing of 16 mm x 2 core wire including connection testing etc. as reqd. |
| 79 | Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required. |
| 80 | 12 way SPN DB |
| 81 | Supply and fixing of 70 Watt LED street light with G.I. pipe bracket with all accessories including connection testing etc as reqd. Please Enable Macros to View BoQ information |