| 1 | Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | 1:2:4 (1 cement : 2 coarse sand (Zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 5 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 6 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 8 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 12 | Foundations, footings, walls, bases of columns, etc. for mass concrete. |
| 13 | Edges of slabs and breaks in floors and walls. |
| 14 | Under 20 cm wide |
| 15 | Suspended floors, roofs, landings, balconies and access platform. |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 18 | Cold twisted/Mild steel and MT steel |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (at all levels) in all shapes and sizes in: |
| 20 | Cement mortar 1: 6 (1 cement: 6 coarse sand) |
| 21 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 (at all levels) |
| 22 | Cement mortar 1: 4 (1 cement: 4 coarse sand) |
| 23 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 24 | Granite of any colour and shade |
| 25 | Area of slab over 0.50 sqm. |
| 26 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 5mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 27 | Second class deodar wood |
| 28 | 35 mm thick |
| 29 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : |
| 30 | 35 mm thick shutters (Second Class Deodar wood) |
| 31 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 32 | 250x16 mm |
| 33 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 34 | 200x10 mm |
| 35 | 100x10 mm |
| 36 | Providing and fixing aluminium handles ISI marked (powder coated) with necessary screws etc. complete : |
| 37 | 125 mm |
| 38 | 250 mm |
| 39 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer, |
| 40 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 41 | Hot finished welded type tubes |
| 42 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 43 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 44 | Providing and laying vitrified floor tiles (Size 600x600 mm) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) jointing with grey cement [email protected] Kg/sqm including grouting the joints with white cement and matching pigments etc. complete |
| 45 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. |
| 46 | Size of tile 600x600 mm |
| 47 | Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design |
| 48 | In 75x75mm deep chase |
| 49 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 50 | 12 mm cement plaster of mix : (Inside) |
| 51 | 1:6 (1 cement: 6 fine sand) |
| 52 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 53 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 54 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 55 | Two or more coats on new work. |
| 56 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 57 | New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 58 | Finishing walls with Acrylic exterior paint of required shade : : |
| 59 | New work (Two or more coat and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 60 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead |
| 61 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 62 | Renewing glass panes, with wooden fillets wherever necessary : |
| 63 | Float glass panes of thickness 4.0 mm thick |
| 64 | Taking out existing wooden door shutter, repair by cutting etc. and refixing of repaired door shutters to existing window frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 65 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: |
| 66 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 67 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: |
| 68 | In cement mortar |
| 69 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. |
| 70 | For thickness of tiles 10 mm to 25 mm |
| 71 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : |
| 72 | Of area of 3 sqm. and below |
| 73 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 74 | For fixed portion |
| 75 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 76 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 77 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 78 | Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . |
| 79 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) |
| 80 | With float glass panes of 5.0 mm thickness |
| 81 | Providing and fixing brass 100 mm mortice latch and lock with 6 levers without a pair of lever handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 82 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 83 | Circular tank |
| 84 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, CP Brass chain with rubber plug, 40 mm C.P. brass waste and 40 mm C.P. brass trap with necessary C.P brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever reqd. |
| 85 | Providing and fixing C.P. brass 3 way laboratory taps of approved quality |
| 86 | Providing and fixing the following sanitary items:- |
| 87 | C.P. Angle valve |
| 88 | C.P. Jali (Grating) |
| 89 | PVC connection |
| 90 | Waste pipe |
| 91 | Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B) |
| 92 | Single Pole |
| 93 | Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required |
| 94 | 40 amps SPN |
| 95 | 63 amps SPN |
| 96 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection. |
| 97 | Providing and fixing 25 mm x 5mm GI strip from earth electrode as required |
| 98 | Supply and fixing of Aluminium flexible cable 2 C x 16 sqmm including connection testing etc as reqd. |
| 99 | Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required. |
| 100 | 12 way SPN |
| 101 | Supply and fixing 1x20 watt fitting complete with extruded aluminiuim tube rod including connection testing etc. as reqd. |
| 102 | Supply and fixing of 12 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL) |
| 103 | Rewiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit (2 mm thick) with modular switch, modulr plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 104 | Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of 3 Pin 6 amp modular switch socket outlet on switch board in surfaced recessed PVC conduit wiring system and 6 amp switch, earth the 3 pin as required with 01 No. PVIC insulated green colour wire. |
| 105 | Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 1.5 mm copper wire for loop earthing required |
| 106 | Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required |
| 107 | Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring ) |
| 108 | Supplying and fixing suitable G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 Ampere and 5/6 Ampere modular socket outlet and 15/16 Ampere modular switch, connection testing etc as reqd. |
| 109 | Supplying and fixing of exhaust fan 300mm sweep heavy duty trans air with double ball bearing including connection, texting etc. as required. |
| 110 | Supplying and fixing of Ceiling fan 1200 mm sweep with double ball bearing including connection, texting etc. as required. |
| 111 | Supplying and fixing of batton holder with 9 watt LED bulb including connections testing etc as reqd. Please Enable Macros to View BoQ information |