Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | RPWS TO KARAMETA :- Supplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge. |
| 2 | Supplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge. |
| 3 | Supplying all labour T&P for Construction of pump house near source as per direction of Engineering In Charge. |
| 4 | Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge. |
| 5 | Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge |
| 6 | Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge |
| 7 | Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge |
| 8 | Add 10 % extra on labour rate for slope roof quantity |
| 9 | Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum. |
| 10 | Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor. |
| 11 | Foundation ,Column , Plinth Bend |
| 12 | Lintel |
| 13 | Roof , Chhaja |
| 14 | Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge. |
| 15 | Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum |
| 16 | Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work |
| 17 | Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips |
| 18 | Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457 |
| 19 | Supplying all labour T & P for White washing two coats with shell lime per sqm |
| 20 | Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm |
| 21 | Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. |
| 22 | Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge |
| 23 | Pump House Door |
| 24 | Toilet Door |
| 25 | Window |
| 26 | Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings) |
| 27 | Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit . |
| 28 | Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit . |
| 29 | Supplying all labour T & P for writing information and draw a logo of BASUDHA |
| 30 | Supplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge. |
| 31 | Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no ) |
| 32 | do-…………group A (1.1.1-1.24.2) |
| 33 | do-…………group B (1.1.1-1.24.2) |
| 34 | Recessed wiring to Fan point in |
| 35 | do-…………group C(1.1.1-1.24.2) |
| 36 | S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4) |
| 37 | S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27) |
| 38 | Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard) |
| 39 | 2 x 1.5 sqmm + 1 x 1.5 sqmm |
| 40 | 2 x 4 sqmm + 1 x 1.5 sqmm |
| 41 | S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28) |
| 42 | Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do- |
| 43 | do- 63amp. T.P.N. Main switch with bus bar |
| 44 | S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1) |
| 45 | S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required |
| 46 | S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required |
| 47 | 150 mm x 100 mm x 60 mm deep (1.24.4) |
| 48 | 180 mm x 100 mm x 60 mm deep (1.24.5) |
| 49 | Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 ) |
| 50 | Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8) |
| 51 | S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL) |
| 52 | Supply. Installation, Testing and commissioning of bulkhead fittings including fixing of 8 watt CFL lamp with die cast aluminium housing and frosted glass cover (Make-Havels ) |
| 53 | S/ F of electric step type fan regulator of ISI marked |
| 54 | S /F of 18 watt CFL lamp |
| 55 | S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board |
| 56 | Supplying all labour T&P for Construction of 60 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge. |
| 57 | Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum. |
| 58 | Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge |
| 59 | Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge |
| 60 | Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge |
| 61 | Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge |
| 62 | Foundation Below Plinth bend |
| 63 | Column & Plinth Bend |
| 64 | Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum. |
| 65 | Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge. |
| 66 | Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge |
| 67 | Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge |
| 68 | Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge |
| 69 | Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge |
| 70 | supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate. |
| 71 | Supply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (5 nos Pump sets including 100% stand-by) |
| 72 | Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP) |
| 73 | Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately). |
| 74 | Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set . |
| 75 | 25 sq. mm Armoured 4 core Aluminium cable reputed make . |
| 76 | 6 sq. mm copper Submersiable flat cable reputed make like . |
| 77 | M.S.Angle frame with suitable nut & bolt with painting.for pannel boards. |
| 78 | Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion. |
| 79 | Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge. |
| 80 | 50 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length.. |
| 81 | Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge. |
| 82 | Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)-50 KL ESR OF 15 MTR STAGGING |
| 83 | Supplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.(110 mm HDPE pipe ,90 mm HDPE Pipe ) |
| 84 | Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil) |
| 85 | Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing.(90 mm HDPE pipe (PN-10)) |
| 86 | Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge |
| 87 | 100 mm GI pipe (MEDIUM) |
| 88 | 80 mm GI pipe (MEDIUM) |
| 89 | Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings |
| 90 | 110 mm HDPE Pipe (PN-6) |
| 91 | 90 mm HDPE Pipe (PN-6) |
| 92 | Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge. |
| 93 | 80mm CI Sluice Valve |
| 94 | 100 mm CI Sluice Valve |
| 95 | 80 mm CI NR Valve |
| 96 | Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge. |
| 97 | 25mm Air Valve |
| 98 | Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge.. |
| 99 | Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge.. |
| 100 | Supply all labour T&P fitting and fixing of construction of Stand post complete as directed by the engineer in-charge.. |
| 101 | Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge. (750 mtr x 0.45 mtr x 0.20 mtr) |
| 102 | Cement concrete (1:4:8) in foundation using 4 cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting,loweing and laying concrete, ramming, watering & curing etc. complete including cost, tax, royalty and conveyance charges of all materials to work site with supply of all labour and T & P required complete as directed by the Engineer-In-Charge. (750 mtr x 0.45 mtr x 0.20 mtr) |
| 103 | Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises. |
| 104 | Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage) |
| 105 | RPWS TO INDRA NAGAR :- Supplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge. |
| 106 | Supplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge. |
| 107 | Supplying all labour T&P for Construction of pump house near source as per direction of Engineering In Charge. |
| 108 | Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge. |
| 109 | Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge |
| 110 | Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge |
| 111 | Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge |
| 112 | Add 10 % extra on labour rate for slope roof quantity |
| 113 | Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum. |
| 114 | Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor. |
| 115 | Foundation ,Column , Plinth Bend |
| 116 | Lintel |
| 117 | Roof , Chhaja |
| 118 | Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge. |
| 119 | Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum |
| 120 | Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work |
| 121 | Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips |
| 122 | Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457 |
| 123 | Supplying all labour T & P for White washing two coats with shell lime per sqm |
| 124 | Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm |
| 125 | Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. |
| 126 | Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge |
| 127 | Pump House Door |
| 128 | Toilet Door |
| 129 | Window |
| 130 | Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings) |
| 131 | Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit . |
| 132 | Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit . |
| 133 | Supplying all labour T & P for writing information and draw a logo of BASUDHA |
| 134 | Supplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge. |
| 135 | Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no ) |
| 136 | do-…………group A (1.1.1-1.24.2) |
| 137 | do-…………group B (1.1.1-1.24.2) |
| 138 | Recessed wiring to Fan point in |
| 139 | do-…………group C(1.1.1-1.24.2) |
| 140 | S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4) |
| 141 | S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27) |
| 142 | Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard) |
| 143 | 2 x 1.5 sqmm + 1 x 1.5 sqmm |
| 144 | 2 x 4 sqmm + 1 x 1.5 sqmm |
| 145 | S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28) |
| 146 | Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do- |
| 147 | do- 63amp. T.P.N. Main switch with bus bar |
| 148 | do- 32amp. T.P.N. Main switch on the pannel board |
| 149 | S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1) |
| 150 | S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required |
| 151 | S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required |
| 152 | 150 mm x 100 mm x 60 mm deep (1.24.4) |
| 153 | 180 mm x 100 mm x 60 mm deep (1.24.5) |
| 154 | Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 ) |
| 155 | Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8) |
| 156 | S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL) |
| 157 | S/ F of electric step type fan regulator of ISI marked |
| 158 | S /F of 18 watt CFL lamp |
| 159 | S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board |
| 160 | Supplying all labour T&P for Construction of 60 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge. |
| 161 | Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum. |
| 162 | Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge |
| 163 | Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge |
| 164 | Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge |
| 165 | Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge |
| 166 | Foundation Below Plinth bend |
| 167 | Column & Plinth Bend |
| 168 | Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum. |
| 169 | Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge. |
| 170 | Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge |
| 171 | Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge |
| 172 | Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge |
| 173 | Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge |
| 174 | supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate. |
| 175 | Supply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (4 nos Pump sets including 100% stand-by) |
| 176 | Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP) |
| 177 | Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately). |
| 178 | Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set . |
| 179 | 25 sq. mm Armoured 4 core Aluminium cable reputed make . |
| 180 | 6 sq. mm copper Submersiable flat cable reputed make like . |
| 181 | M.S.Angle frame with suitable nut & bolt with painting.for pannel boards. |
| 182 | Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion. |
| 183 | Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge. |
| 184 | 50 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length.. |
| 185 | Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge. |
| 186 | Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)-50 KL ESR OF 15 MTR STAGGING |
| 187 | Supplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.( 90 mm HDPE Pipe ) |
| 188 | Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil) |
| 189 | Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing(90 mm HDPE pipe (PN-10)) |
| 190 | Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge |
| 191 | 100 mm GI pipe (MEDIUM) |
| 192 | 80 mm GI pipe (MEDIUM) |
| 193 | Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings |
| 194 | 90 mm HDPE Pipe (PN-6) |
| 195 | Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge. |
| 196 | 80mm CI Sluice Valve |
| 197 | 100 mm CI Sluice Valve |
| 198 | 80 mm CI NR Valve |
| 199 | Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge. |
| 200 | 25mm Air Valve |
| 201 | Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge.. |
| 202 | Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge.. |
| 203 | Supply all labour T&P fitting and fixing of construction of Stand post complete as directed by the engineer in-charge.. |
| 204 | Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge.( 300 mtr x 0.45 mtr x 0.20 mtr) |
| 205 | Cement concrete (1:4:8) in foundation using 4 cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting,loweing and laying concrete, ramming, watering & curing etc. complete including cost, tax, royalty and conveyance charges of all materials to work site with supply of all labour and T & P required complete as directed by the Engineer-In-Charge. (300 mtr x 0.45 mtr x 0.20 mtr) |
| 206 | Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises. |
| 207 | Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage) |
| 208 | O&M cost for 5 Years (For KARAMETA) |
| 209 | O&M cost for 5 Years (For INDRA NAGAR) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail