| 1 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking into pieces not exceeding 0.02 cum in volume, and stacking serviceable materials at designated locations and disposing of dismantled materials up to a lead of 1000 metres, including stacking serviceable and unserviceable materials separately, complete as per the direction of the Engineer-in-Charge. |
| 2 | Cutting asphalt / bituminous road of flexible pavement, dismantling materials up to a lead of 1000 metres, stacking serviceable materials separately and disposing of unserviceable materials, including cost of all labour, tools & plants (T&P), etc., complete as per the direction of the Engineer-in-Charge. |
| 3 | Dismantling of cement concrete paver block flooring/pavement, including removal of paver blocks and bedding layer, sorting and stacking of serviceable materials, disposal of rubbish within specified lead, as directed by Engineer-in-Charge. |
| 4 | Earthwork excavation For laying of Waste water pipe line from Inspection chamber to manhole chamber (DWC Pipe)Supplying all labours and T&P for earth work in all kind of soil within 50mtr inttial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge. Upto 1.50 mtr. Depth |
| 5 | Excavation of foundation in laterite rock or any hard rock (other than granite )removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Upto 1.50 mtr. Depth |
| 6 | For laying of Waste water pipe line from MH to MH & MH to STP (DWC Pipe) & RCC Hume PipeSupplying all labours and T&P for earth work in all kind of soil within 50mtr inttial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge. Upto 1.50 mtr. Depth |
| 7 | Beyond 1.50 - 3.00 mtr. Depth |
| 8 | Excavation of foundation in laterite rock or any hard rock (other than granite )removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Beyond 1.50 - 3.00 mtr. Depth |
| 9 | For construction of Manhole chamberSupplying all labours and T&P for earth work in all kind of soil within 50mtr inttial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge. Upto 1.50 mtr. Depth |
| 10 | Beyond 1.50 - 3.00 mtr.Depth |
| 11 | Excavation of foundation in laterite rock or any hard rock (other than granite )removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Upto 1.50 mtr. Depth |
| 12 | Beyond 1.50 - 3.00 mtr. Depth |
| 13 | Pipe BeddingProviding and laying sand bedding for sewer line trenches, including watering, ramming and consolidation by punners, complete with an initial lead of 50 metres as per specification and direction of Engineer-in-Charge.For 50mm Dia (Treated Line ) &150 mm dia (GM,HC & RM ) |
| 14 | Supplying all materials, labour, T & P for refilling the trenches with Sand , including watering, ramming and consolidation, etc complete as per specification and direction of the Engineer-in-Charge. |
| 15 | Disposal of debris/surplus excavated material to the site about 5km away from the work site, complete as per standard detailed technical specifications and approved design and drawings, including hire charges of machineries, loading and unloading charges, with all lead and lift and any other incidental charges, complete direction of Engineer-in-charge. |
| 16 | Supplying all materials, labour, T&P for construction of circular type manholes with cover slab of Reinforced cement concrete M25,HD 20 precast manhole cover and ring, bottom slab & shaft made of Reinforced cement concrete M25 below 1.5m upto required depth with graded granite stone aggregate, foundation concrete(1:3:6) using graded HG stone aggregate 40mm nominal size, inside plastering 6mm thick (1:4) finished smooth with neat cement punning, outside plaster 12mm thick(1:4) and making benching with cement concrete M25 using graded granite stone aggregate, making smooth to the surface of benching and channel, testing & commissioning, lighting, watch & ward etc., all complete as per approved design & drawing & direction of Engineer in charge. (Excluding excavation which will be done separately as per site condition)Size:- 1.20 x 0.90mtr (Circular) |
| 17 | Every Additional Depth of 0.10 mtr or part thereof upto 1.50 mtr. |
| 18 | Size:- 1.20 x 1.67mtr (Circular) |
| 19 | Every Additional Depth of 0.10 mtr or part thereof upto 2.30 mtr. |
| 20 | Every Additional Depth of 0.10 mtr or part thereof beyond 2.3m upto 3.0 mtr. |
| 21 | Every Additional Depth of 0.10 mtr or part thereof beyond 3.0m upto 4.5 mtr. |
| 22 | Supplying all materials,labour and T&P for Construction of Gully trap with R.C.P.C. top slab in (1:1.5:3 ) mix with inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3), flyash brick work with flyash bricks with crushing strength not less than 75kg/sqcm. in cement mortar (1:3) finished smooth complete as per specification & direction of Engineer in charge. Size 250 x 250x 675 mm |
| 23 | Supplying all materials,labour and T&P for Constructing Inspection chamber with top slab in (1:1.5:3 ) mix & R.C.P.C. with inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3), flyash brick work with flyash bricks with crushing strength not less than 75kg/sqcm. in cement mortar (1:3) finished smooth complete as per specification & direction of Engineer in charge. Size 0.75 x 0.75 x 0.45 m |
| 24 | Supplying all materials,labour and T&P for Re-Construction of damaged Inspection chamber with R.C.P.C. top slab in (1:1.5:3 ) mix with inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3), flyash brick work with flyash bricks with crushing strength not less than 75kg/sqcm. in cement mortar (1:3) finished smooth complete as per direction of Engineer-in-charge.Size 0.75 x 0.75 x 0.75 m |
| 25 | Supply, delivery & laying the following size of ISI marked PVC SWR S/S Vertical Downtake pipes (ISI Type - B) of approved diameter and rubber ring gasket and all other materials, labour, T & P, and lowering the pipes in to the trench, aligning, laying to approved level or slope as per P.H. specification and direction of Engineer-in-charge.Size 110mm OD SWR Pipe |
| 26 | Providing, supplying, lowering and Hydraulic Testing instandard length (PE material) DWC pipe Structured-Wall plastic piping system for non pressure underground drainage and sewerage with smooth internal & corrugated external surface confirming to IS16098:Part-2 2013with spigot or plain endwith necessary jointing material coupler including transportation and freight charges, inspection charges, loading and unloading charges, conveyance to departmental store and stacking the same in closed shadeduly protecting from direct sun ray and rains excluding GST levied by Gol and GoM in all respect , etc. complete. Best NABL Approved Vendor tets Report submitted and Approved by Client engineer Incharge. PE / DWC SN-8150 mm (GM & HC ) dia |
| 27 | Providing and supplying ISI standard HDPE / DWC specials / specials such as bend,tee, all angleand other on site required Specails excluding GST levied by GOI & GOM in all respect, railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store/site,unloading stacking etc. complete as per direction of Engineer-in-charge. Size 100 mm to 200 mm dia |
| 28 | Providing ,supplying and Laying DI Tamper proof Kinetic Air Valve (Make:VAG/ Talis/ AVK/IVC/ Kirloskar/Hawle/Equivalent make with approval of the authority) confirming to IS 14845 as per standard specifications having small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, with built-in Kinetic features, isolating sluice valve mounted in horizontal position and operated by wheel gearing, inlet face and drilled, including insurance. third party inspection charges, loading, unloading. transportation upto departmental stores, excluding GST as per PH specification and direvtion of Engineer-in-charge.Size 25 mm dia |
| 29 | Supplying all labour, T&P materials etc. and the construction of brick masonry sluice valve chamber of over all of following internal ; earth work in excavation in all kinds of soil; laying of 150mm thick CC (1:3:6) with crusher broken hard granite metal up to 4 cm size metal; 250mm thick brick masonry workin C.M (1:4) with fly ash bricks having crushing strength betgween 75 Kg/cmsq. 12mm thick cement plastering with CM(1:3) with punning for inside surfaces & out side plastering above GL & cement pointing below GL etc. all complete including precast Factory made Heavy duty RCC cover slab with Frame made out of M30 concrete to with stand against 20 MT vehicular load as per the approved drawing if any and the direction of Engineer-in-charge.Air valve chamber (without cover slab)Size: 0.75 x 0.75 x 1.10 m |
| 30 | Dewatering of excavated trenches and pools of water in building trenches / pipeline trenches, well works by using pumps and other devices, including disposal of water to a safe distance as directed by the Engineer-in-Charge, complete as per specification. |
| 31 | Providing and fixing minimum 50 mm dia Bamboo for covering the barricading in one/two rows one above another and painiting in red and white sheets as per the specifications and direction of Engineer in charge with proper fixing arrangements with Gl implet washers nuts & bolts complet in all respect. |
| 32 | Supplying all labour, tools & plants for rigid & smooth shoring and shuttering with wooden planks of suitable thickness, hoisting & placing in position of wooden planks and runner, bracing with wooden posts and fixing with sutiable wooden runner etc. wherever necessary at suitable intervals, including cost of all materials, royality, taxes, conveyance of all materials to site and installing in trench on both side upto required depth to retain earth for sewer lines and manholes, dismantling the shoring and shuttering etc. all complete as per direction of Engineer-in-charge.Lift upto 1.50 m depth |
| 33 | Lift beyond 1.50 m depth |
| 34 | ROAD RESTORATION (CC ROAD )Cement concrete (1:3:6) with 40mm. Size crusher broken hard Granite 1 metal including cost of all labour m³ ,materials with all taxes, lead, T & P etc all complete. |
| 35 | Cement concrete (1:1.5:3)with 12mm size crusher broken hard granite chips including cost of all labour, materials with all taxes, lead, T & P etc all complete. |
| 36 | ROAD RESTORATION (BT ROAD )Construction of granular sub base by providing closed gradded granular sub base Gradding -VI (0.15 mtr thick) materials as per est table 400-1 spreading in uniform layers with mortor grader on prepared surface, mixing by in place method with rovator at ate OMC and campacting with vibratory roller to achieve the desired density complete as per clause 401 of MoSRT&H specification for road & bridge work etc complete & as directed by Engineer-in-Charge |
| 37 | Providing and laying spreding and compacting graded stone aggregate to Wet Mix Macadam (0.25 mtr thick) specification including premixing the materials with watered at OMC in Mechanical mix plant, carriage of mixed materials by tipper to site, laying inuniform layer with paver in subbase /base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406 of MoSRT&H specification for road and bridge work & as directed by Engineer-in-Charge |
| 38 | Providing 50 mm thick Bitumen Macadam using crushed stone Gradding II materials & 60/70 penetration grade of bitumen as per approved drawing & technical Specification and as per Clause - 504 of MoSRT&H specification for Road & bridge work & as directed by Engineer-in-Charge |
| 39 | Providing tack coat on preppared surface with bitumen emulsion as per technical specification and as per Clause 503 of MoSRT&H specification for Road & bridge work & as directed by Engineer-in-Charge |
| 40 | Providing 25 mm Thick & 2.50 mtr width Semi Dence Bituminous concrete er Latest using crushed stone Gr-II materials & 60/70 penitration grade Droved of bitumen as per approved Drawings & technical ate Date Specification and as per Clause 506 of MoSRT&H 1/2024 Specification for Roads and Bridge works Paver Block ( Restoration ) & as directed by Engineer-in-Charge |
| 41 | Paver Block ( Restoration )Providing and laying of 60mm thick factory made cement concrete interlocking paver block of M 35 grade and approved make, colour and size made by block making machine with strong vibratory compaction of approved size design and shape laid in required colour and pattern over and including 50mm thick compacted bed of sand etc complete coarse sand , filling the joints with the sand etc all complete including cost conveyance, royalties and taxes of all materials and cost of all labour, etc. complete as directed by Engineer in charge.Reuse of Material (labour charges only) |
| 42 | New material for restoration including labour charges |
| 43 | CC ROAD ( Internal Road )Supplying all labours and T&P for earth work in all kind of soil within 50mtr inttial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge. |
| 44 | Supplying all materials, labour, T & P for refilling the trenches with Sand in layers of 100mm thick, including watering, ramming and consolidation, etc complete as per specification and direction of the Engineer-in-Charge. |
| 45 | Cement concrete (1:3:6) with 40mm. Size crusher broken hard Granite 1 metal including cost of all labour m³ ,materials with all taxes, lead, T & P etc all complete. |
| 46 | Cement concrete (1:1.5:3)with 12mm size crusher broken hard granite chips including cost of all labour, materials with all taxes, lead, T & P etc all complete. |
| 47 | R.C.C DRAINSupplying all material, labour, T & P for construction of R.C.C surface drain for disposal of rain water etc from the premises of ETP / STP (0.25m width x 0.30m depth) etc all complete as per approved drawing, specifications & direction of Engineer-in-charge. |
| 48 | PLANT-cum-SCADA ROOMSupplying all material, labour, T & P for construction of Plant room using R.C.C Column, R.C.C Beam, Lintel, Chajja, Roof Slab, Fly ash brick work in C.M( 1:6), Cement plaster & painting works with lead and lift of all materials to site including required W/S & SI and internal electrification all complete as per approved drawings, specifications and direction of Engineer-in-Charge. |
| 49 | CHEMICAL STORAGE ROOMSupplying all material, labour, T & P for construction of Chemical storage room using R.C.C Column, R.C.C Beam, Lintel, Chajja, Roof Slab, Fly ash brick work in C.M( 1:6), Cement plaster & painting works with lead and lift of all materials to siteincluding required W/S & SI and internal electrification all complete as per approved drawings, specifications and direction of Engineer-in-Charge. |
| 50 | COMPOUND WALLSupplying all material, labour, T & P for Construction of RCC framed Boundary Wall with fly ash brick including earthwork, sand filling, CC (1:3:6), R.C.C work, brick work, plastering, painting, etc. all complete as per approved design and drawings, specifications and direction of Engineer-in-charge. Compound wall (1.80 M Ht.) |
| 51 | Supplying all material, labour, T & P for provision of SS Gate including construction of 2 nos. R.C.C pillar, plastering, finishing etc all complete as per approved drawings and direction of Engg.-in-charge.2 Leaf SS Gate (size 6.0M X 1.8 M Ht.)-1 No.1 Leaf SS Gate (size 1.3M X 1.8 M Ht.)-1 No. |
| 52 | Designing, drawing, supplying, constructing, testing & commissioning of Effluent Treatment Plant (ETP) & Sewage Treatment Plant (STP) of required capacity and appropriate technology (MBBR / SBR / MBR) including all civil, electro-mechanical works, tertiary treatment system, automation etc all complete to achieve desired effluent quality as per NGT norms. (Excluding cost of SCADA system, PLC, plant room, chemical storage room, yard lighting, compound wall, external electrification, treated water storage sump and re-use/disposal arrangements)ETP- 40 KLDSTP- 160 KLD |
| 53 | Supply, Installation, Testing and Commissioning of Multiparametric Online Continuous Effluent Monitoring System having facilities for pH, COD, BOD TSS analyzer as per technical specifications attached including ( One) year guarantee. Make-XYLEM/SCAN/HORIBA/Equivalent make with approval of authority. |
| 54 | Supply,Installation & Commissioning of SCADA software (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority) with Graphical processor visualisation Advanced alarm management,historical and Real time trending,Built-inreporting, Stastical process control,Multithreaded citect VBA and Cicode programming language with 2048 Tag SCADA Software (ES+OS) (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority),1KVa online Ups with 30Min batery backup- 1Nos,CPU Having Preloaded win-10 Proffessional, I3-10gen 2.4 Ghz Prrocessor, DDR4 8gb Ram, 500 gb 7200 Rpm HDD-1 Nos (Make-HP, DELL, LENOVO), USB based keyboard - 1Nos,USB based Optical Mouse- 1Nos,43'' LED monitor - 1Nos,A4 size laserPrinter - 1Nos,Wooden Computer table - 1 Nos ,Preparation of P&I diagram, Creation of Multi visualization screen for Process control,alarm managenent, Historical and realtime process trend, Daily reporting etc complete as per requirement & direction of Engineer - in - Charge. (Including license key) |
| 55 | Supply,installation & commissioning of PLC Panel with following technical specification i,e. Enclosure: 800x800x2100mm-01 No with double door & lock, CPU should have 1 MB program memory with extended memory slut ,Redundand-24VDC,SMPS 10Amp along with 24V DC SPD,IO count as DI-16,DO-20,AI-20,AO-08 & MODBUS-10 subsystem shall be of same series as CPU,10\\" Panel Mounted HMI,Modem should have support MQTT Protocol by default, 24volt DC Industrial switch with minimum 6 eathernate, 4 SFP Port each AI shall be equiped with sutitable signal isolator of 20 Nos & surge protection device 20 nos LIU Isolater, 230Volt AC/230volt AC torroidal transformer,1KVA 230V AC industrial grade UPS of 8 hrs backup to charge 3 nos 12 VDC 65 AH Battery ,DP MCB of Adequate current capacity,LED tube light 10\\" 5 watt,door limit switch,Fan 6\\" with louver,4 sqmm straight through terminal & fuse terminal 90 nos, with PE & EE.The Approved Make : (Make:- Siemens,Schnider,ABB,Mitsubishi/Equivalent make with approval of authority) including cost of material with all taxes transporataion to Site/Storage with insurance.Programme to be handed over with upload & download facilities for departmental use. |
| 56 | Treated water storage sumpConstruction of Treated water storage sump of required capacity using RCC including plastering, painting, epoxy treatment, etc. all complete as per approved design and drawings and as per direction of Engineer-in-charge. |
| 57 | Supply, Installation, Testing and Commissioning of Submersible pump set with required control panel and electrical installation all complete as per approved design and drawings and as per direction of Engineer-in-charge. (1W + 1S) (each having duty Q=12cum/hr & H=15mtr.) |
| 58 | Providing and supplying in standard lengths High Density Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc complete as per direction of Engineer-in-charge.50mm dia HDPE (PE-80) pipe |
| 59 | Providing and supplying ISI standard HDPE / DWC specials such as bend,tee, all angleand other on site required Specails excluding GST levied by GOI & GOM in all respect, railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store/site,unloading stacking etc. complete. |
| 60 | Ball valvesSize 50mm dia |
| 61 | Constructing Fullway valve chamberSize (0.45mx0.45mx0.60m) |
| 62 | YARD LIGHTINGSupply fitting fixing & errection of Hot dip octagonal smart pole for mounting and installation of the LED street light Luminaries as per following technical specifications - (i) Height - 6.00 mtr (ii) Top dis - 70 mm (iii) Bottom dia -130mm (iv) Sheet thichness - 3 mm (v) Base plate dimension - 200 mm x 200mm x 12mm with required bolt & fittings including supplying fitting & fixing of Single arm Bracket of 1.0 mtr length suitable for fixing in 70mm top yard lighting octagonal smart pole with fitting & fixing of 60 watt LED street light light made up cast aluminium housing with high efficiency LED as lighting source and Toughened glass have Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including commissioning etc all complete as per electrical specification and direction of Engineer-in-charge. |
| 63 | EXTERNAL ELECTRIFICATIONSupply, installation, testing and commissioning of 3-phase, 11/0.4 kV LT power supply system including installation of transformer with all associated materials, accessories and fittings complete in all respects as per relevant electrical & IS specification. (Work shall be executed under the supervision of TPCODL/ TPSODL/ TPNODL/ TPWODL Authorities as per their estimate and payment shall be made accordingly as per actual)Transformer of 250 KVA capacity |
| 64 | Supply, installation, testing and commissioning of LT overhead line up to transformer yard including conductor, GI poles, stays, insulators and allied materials etc. all complete. (Work shall be executed under the supervision of TPCODL/ TPSODL/ TPNODL/ TPWODL Authorities as per their estimate and payment shall be made accordingly as per actual)11 kv Line with 160x160 mm GI Pole |
| 65 | DG SETDesign, engineering, procurement of materials and bought out components, manufacturing, assembly at shop, inspection, testing and painting at manufactures works, packing, supply, unloading/ transportation/ handling/ storage at site, assembly at site, installation including touch-up painting, hook-up, pre-commissioning, commissioning, inspection and testing of the complete of the following capacity (prime power) DG sets along with AMF panels. Acoustic enclosure, supply of all erection & commissioning spares, special tools and tackles (as required), instrumentation, all auxiliaries, Exhaust system & silencer, Fuel tank, Fuel piping etc all complete including RCC foundation,DG set Shed,Chemical earthing 4 nos,Al power cable of required length,trial run with required amount of diesel as per directrion of EIC in complience with CPCB IV norms. (Make:- Mahindra Power/ Kirloskar/Ashok Leyland/Sterling/Jackson/ Cumin Powers/ Greaves Cotton/ Greaves/TMTL/Captiva/Equivalent make with approval of the authority)DG Set of 160 kVA Capacity |
| 66 | Design, manufacture, supply, inspection, handling, installation, testing and commissioning of floor-mounted, extensible type, cubical Main LT Panel fabricated out of 1.6/2.0 mm thick CRCA sheet steel, dust and vermin proof, front operated construction, enclosure protection class IP-42, conforming to IEC 60439. The panel shall be surface treated with 9-tank process and provided with top/bottom removable gland plates, double compression type cable glands, earth bus, hinged and lockable doors, and all internal interconnections complete as required for plant operation, as per the direction of the Engineer-in-Charge. |
| 67 | 5 years of Operation & MaintenanceWaste Water Collection System Operation and Maintenance for the first 5 years from Commissioning of the Work and Treatment plant O&M, including deployment of Skilled Man Power, Chemical consumption, operation consumables for ETP & STP plant operation.1st year O & M |
| 68 | 2nd year O & M |
| 69 | 3rd year O & M |
| 70 | 4th year O & M |
| 71 | 5th year O & M Please Enable Macros to View BoQ information |