| 1 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, as required, duly suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 2 | 100 mm width X 50 mm depth X 1.6 mm thickness (with 40 x 6 mm GI angle supports and 10mm dia GI rod hangers) |
| 3 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of the following size directly in the ground, including excavation, sand cushioning, protective covering, and refilling the trench etc, as required- |
| 5 | Up to 35 sq mm |
| 6 | Above 185 sq. mm and up to 400 sq. mm |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required- |
| 8 | 3½ X 300 sq. mm (70mm) |
| 9 | 4 X 25 sq. mm (28mm) |
| 10 | Supply of the following size 1.1 grade XLPE insulated, PVC Sheathed, Aluminium conductor armoured cable conforming to IS 7098 (Part-1) 1988 with up-to-date amendments etc., as required. |
| 11 | 3.5 X 300 Sq.mm. Al armoured Cable |
| 12 | Supply of following size 1.1 grade XLPE insulated, PVC Sheathed, Cu conductor Unarmoured cable conforming to IS 7098 (Part-1) 1988 with up to date amendments etc. as required. |
| 13 | 4 X 25 sq mm Cu Unarmoured Cable |
| 14 | Medium clas PVC conduit pipe 40 mm ISI marked,along with all accessories sockect,coupler,bend etc |
| 15 | Solar MC4 Connector |
| 16 | Solar Mid Clamp with all accessories |
| 17 | Solar Inline MC4 fuse connector with 1000v 15 A current rating |
| 18 | Earthing with cu polished 3 m long including all accessories with cover plate having locking arrangememt |
| 19 | Solar DC cable 4sq mm |
| 20 | Shifting of existing 300KWP solar Modules, inverters, ACDB and other accessories from OPD parkimg(Near STP) to Auditroium Parking. |
| 21 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 22 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 24 | Foundations, footings, bases of columns, etc. for mass concrete |
| 25 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 26 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 27 | Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 28 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: |
| 29 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 30 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
| 31 | cement mortar 1:4 (1 cement : 4 coarse sand) |
| 32 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 33 | Hot finished welded type tubes |
| 34 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 35 | 12 mm cement plaster of mix : |
| 36 | 1:4 (1 cement: 4 fine sand) |
| 37 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 38 | 1:4 (1 cement: 4 fine sand) |
| 39 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge |
| 40 | In cement mortar Grand Total |