| 1 | Supply, install, testing and commissioning of air cooled split type air conditioners electric driven (240 Volts, single phase, 50 Hz) with energy efficient Rotary Compressor, working on R-22 or superior environment- friendly refrigerant, cordless remote operated, comprising of indoor unit, wall mounted, material of construction of indoor unit ABS nominal cooling capacity 4500 KCal/ Hr, power consumption (Max) 4275 Kcal/Hr, outdoor unit, material of cabinet GI sheet 10.0 mm thick powder coated, Copper tubing electric connecting (Between indoor and outdoor unit located uoto a maximum distance of 10 Mtr) and condensate water drainage arrangement etc complete of capacity 1.5 Ton (EPBAX Room) all as specified and directed by Engr-in-Charge.Note : The Split AC shall carry minimum 5 Star rating as per bureau of Energy Efficient (BEE) lebelling programmed. |
| 2 | S&F PVC pipe medium grade of 16 mm bore with and including all fittings and fixed complete to wall and ceillings or laid in floors for draining out water from outer unit complete all a specified and as directed by Engr-in-Charge. |
| 3 | S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and of capacity 4 KVA all as specified and directed. |
| 4 | S&F MCB SP 6 to 32 Amps, 240 Volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed. Type ' C' Characterstic. |
| 5 | M&L for sub main wring with two run of single core PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 Volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 4.00 Sqmm,1100 volts grade as earth continuity conductor as per colour code) drawn through in and including PVC Casing caping of suitable size with all accessories such as bend, elbow, tee etc complete all as specified and directed.Note : 3 runs of 4 Sqmm wire and 1 run of casing caping shall be measured as one length. |
| 6 | S&F MCB TPN 40 to 100 Amps , 240 Volts, 50 HZ, 10 KA breaking capacity complete all as specified and directed. Type 'C' Characterstic. |
| 7 | S&F sheet metal enclosure for DB's TPN Double door 4 Way, AC, 415 Volt, IP 43 on the wall complete & making good disturbed surface of masonry works with cement plaster in cement mortar (1:6) and distempering / white washing to match the existing suface complete all as specified and directed. |
| 8 | S&F sheet metal enclosure for DB's for plug and socket SP, AC 240 volt with MCB SP 20 Amp on the wall complete & making good disturbed surface of masonry works with cement plaster in cement mortar (1:6) and distempering / white washing to match the exsting surface complete all as specified and directed. |
| 9 | S&F of UG Cable XLPE insulated armoured heavy duty electriuc cable with aluminium conductor, 1100 volts grade, cross section area of size 35 Sqmm 3.5 core complete all as specified and directed. |
| 10 | Excavation in trenches manually not exceeding 1.5m wide and not exceeding 1.5 mtr in depth/ width for laying under ground cable / foundations and gettting out in soft/ loose soil complete all as specified and directed.Note : During excavatiion no mechanical excavator is permitted at site, contractor will do the excavation through manually only. |
| 11 | Returning, filling in including spreading, Levelling, watering and well ramming in layers not exceeding 25cm all as sopecified and directed. |
| 12 | Removing of surplus excavating material not exceeding 50 Mtr and depositing where directed at a levell not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 13 | M&L for sand cushioning for protection of LT under ground cable with screen wash sand and punning to proper required cover all as specified and direcrted. |
| 14 | S&F double wall corrugated pipe of size 63mm all as specified and directed by Engr-in-Charge. |
| 15 | M&L for Earthing complete with Galvanised iron earth plate electrode of size 600X600X6mm thick buried directly in ground with earth pit not less than 2.25 mtr deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanised iron earth strip of size protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42X42X10 cm thick reinforced with 8mm dia TMT bars@ 150mm c/c both ways with 10mm dia mild steel round bar of 30cm long, bent to shape as lifting handle, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, earth tesitng point, charcoal or coke and salt in alternate layers with necessary earth work in soft / loose soil complete all as as shown in electeical plate No. 3 of SSR Part-I including testing on completion complete all specified and directed. (copper strip upto 7.5m including testing deemed to be included in this item) Please Enable Macros to View BoQ information |