| 1 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in following type soil for laying cables etc complete all as specified and as directed by the Engineer - in - Charge. |
| 2 | Soft/Loose Soil complete all as specified and as directed. |
| 3 | Hard/Dense Soil complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. |
| 5 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. |
| 6 | Material and labour for dry river sand cushioning over and around the cable for cable protection in trenches, leveled and punned down complete all as specified and as directed by the Engineer - in - Charge. Note: The punned down thickness shall be measured for payment. |
| 7 | Supplying and laying GI pipe, 40 mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed by the Engineer - in - Charge. |
| 8 | Supplying and laying GI pipe, 80 mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed by the Engineer - in - Charge. |
| 9 | Supplying and laying GI pipe, 100 mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed by the Engineer - in - Charge. |
| 10 | Supplying and laying GI pipe, 150 mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed by the Engineer - in - Charge. |
| 11 | Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type - 1, Flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with \\" LV ELECTRIC\\" on the top surface complete all as specified and as directed by the Engineer - in - Charge. |
| 12 | Supply, lay, joint, test and commission LT under ground cable 1100 V grade, XLPE insulated, armoured and sheathed with Aluminium conductor of following sizes including cable glands, lugs, jointing materials etc laid in trenches / floors / ducts all as specified and directed including taking out of unserviceable cable whereever feasiable. Note: Earth work and excavation shall be measured and paid separately for laying /taking out of old cables. |
| 13 | 500 Sqmm 3.5 core (The existing cable is pasing through main roads/ below the buildings etc and not feasible to take out, hence same will be used as standby cable) complete all as specified and as directed. |
| 14 | 400 Sqmm 3.5 core (The existing cable is pasing through main roads/ below the buildings etc and not feasible to take out, hence same will be used as standby cable) complete all as specified and as directed. |
| 15 | 240 Sqmm 3.5 core (The existing cable is pasing through main roads/ below the buildings etc and not feasible to take out, hence same will be used as standby cable) complete all as specified and as directed. |
| 16 | 185 Sqmm 3.5 core complete all as specified and as directed. |
| 17 | 120 Sqmm 3.5 core complete all as specified and as directed. |
| 18 | 95 Sqmm 3.5 core complete all as specified and as directed. |
| 19 | 10 Sqmm 4 core complete all as specified and as directed. |
| 20 | Design, supply, install, testing and commissioning of factory made LT Panel Indoor type, cubical enclosure compartmentalized external and internal mirror type brushed finish suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side in seperate cable alley on both side, seperated with bakelite sheet of suitable size, including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of TPN aluminium bus bars of size 1.5 time of main incomming rating switch gear and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:- |
| 21 | Contd…./-Incomimg:-(a) ACB 1000 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Electrically operated ( EF ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable and out going cables complete- 1 No [Make- L&T/Legrand/Siemens/ Schneider](b) On load change over switch 1000 amps capacity, 4 pole, open execution type, 415 volt 50 Hz AC Supply complete. -01 No(c) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (d) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 630 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 01 No with RHOM. (b) MCCB 400 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 03 No with RHOM. (c) MCCB 250 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 01 No with RHOM. (d) MCCB 200 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 01 No with RHOM. |
| 22 | All as per Item No 11.00 here-in-before complete but with the foillowings :- Incoming:-(a) ACB 630 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Electrically operated ( EF ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable and out going cables complete- 1 No [Make- L&T/Legrand/Siemens/ Schneider](b) On load change over switch 630 amps capacity, 4 pole, open execution type, 415 volt 50 Hz AC Supply complete. -01 No(c) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (d) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 400 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 01 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCCB 160 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 03 No with RHOM. (L&T/Siemens/Schneider/Legrand)(c) MCCB 125 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 02 No with RHOM. (L&T/Siemens/Schneider/Legrand) |
| 23 | All as per Item No 11.00 here-in-before complete but with the foillowings :- Incomimg:-(a) ACB 800 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Electrically operated ( EF ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable and out going cables complete- 1 No [Make- L&T/Legrand/Siemens/ Schneider](b) On load change over switch 800 amps capacity, 4 pole, open execution type, 415 volt 50 Hz AC Supply complete. -01 No(c) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (d) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 500 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 01 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCCB 400 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 01 No with RHOM. (L&T/Siemens/Schneider/Legrand)(c) MCCB 315 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 01 No with RHOM. (d) MCCB 250 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 02 No with RHOM. (L&T/Siemens/Schneider/Legrand) |
| 24 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 400 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable - 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 200 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 05 No with RHOM. (L&T/Siemens/Schneider/Legrand). |
| 25 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 200 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 04 No with RHOM. (L&T/Siemens/Schneider/Legrand). |
| 26 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 200 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand) (b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 05 No with RHOM. (L&T/Siemens/Schneider/Legrand) |
| 27 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 200 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand) (b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 7 Nos with RHOM. (L&T/Siemens/Schneider/Legrand) |
| 28 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 400 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM [Make- L&T/Legrand/Siemens/ Schneider](b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 200 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 5 No with RHOM. (L&T/Siemens/Schneider/Legrand) |
| 29 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 200 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 160 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 1 No with RHOM. (b) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 5 No with RHOM. |
| 30 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 200 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 3 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCB 63 Amps 3 pole rupturing capacity 10 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 14 No. with RHOM (L&T/Siemens/Schneider/Legrand) |
| 31 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 200 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand) (b) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 3 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCB 63 Amps 3 pole rupturing capacity 10 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 14 No. (L&T/Siemens/Schneider/Legrand) |
| 32 | All as per Item No 11.00 here-in-before complete but wall mounted panel, front openable, fixed on angle iron frame made out of 50x50x6 mm angle iron duly grouted on wall with the foillowings :- Incomimg:-(a) MCCB 200 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 1 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCB 63 Amps 3 pole rupturing capacity 10 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 6 No. (L&T/Siemens/Schneider/Legrand). |
| 33 | All as per Item No 11.00 here-in-before complete but with the foillowings :- Incomimg:-(a) ACB 800 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Electrically operated ( EF ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable complete- 1 No [Make- L&T/Legrand/Siemens/ Schneider](b) On load change over switch 800 amps capacity, 4 pole, open execution type, 415 volt 50 Hz AC Supply complete. -01 No(c) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (d) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 250 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 02 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCCB 200 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 01 No with RHOM. (L&T/Siemens/Schneider/Legrand) (c) MCCB 160 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 02 No with RHOM. (L&T/Siemens/Schneider/Legrand)(d) MCCB 100 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 07 No with RHOM. (L&T/Siemens/Schneider/Legrand). |
| 34 | Design, supply, install, testing and commissioning of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed finish suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side in seperate cable alley on both side, seperated with bakelite sheet of suitable size, including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of TPN aluminium bus bars of size 1.5 time of main incomming rating switch gear and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: |
| 35 | Contd…./-Incomimg:-(a) ACB 630 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Electrically operated ( EF ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable and out going cables complete- 1 No [Make- L&T/Legrand/Siemens/ Schneider](b) On load change over switch 630 amps capacity, 4 pole, open execution type, 415 volt 50 Hz AC Supply complete. -01 No(c) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (d) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 400 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 01 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCCB 200 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 03 No with RHOM. (L&T/Siemens/Schneider/Legrand)(c) MCCB 125 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 03 No with RHOM. (L&T/Siemens/Schneider/Legrand). |
| 36 | All as per Item No 24.00 here-in-before complete with the foillowings :- Incomimg:-(a) MCCB 400 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable and out going cables complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 200 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 01 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 03 No with RHOM. (L&T/Siemens/Schneider/Legrand)(c) MCCB 100 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 04 No with RHOM. (L&T/Siemens/Schneider/Legrand). |
| 37 | All as per Item No 24.00 here-in-before complete with the foillowings :- Incomimg:-(a) MCCB 500 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable and out going cables complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 250 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 02 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 02 No with RHOM. (L&T/Siemens/Schneider/Legrand)(c) MCCB 100 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 02 No with RHOM. (L&T/Siemens/Schneider/Legrand). |
| 38 | All as per Item No 24.00 here-in-before complete with the foillowings :- Incomimg:-(a) MCCB 250 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable and out going cables complete- 1 No with RHOM (L&T/Siemens/Schneider/Legrand)(b) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA ,V, I and WH including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 SetOutgoings:-(a) MCCB 125 Amps 3 pole rupturing capacity 36 KA at 415 volt , 50 Hz AC supply Ics=100% Icu - 04 No with RHOM. (L&T/Siemens/Schneider/Legrand)(b) MCCB 100 Amps 3 pole rupturing capacity 25 KA at 415 volt , 50 Hz AC supply Ics= 100% Icu - 03 No with RHOM. (L&T/Siemens/Schneider/Legrand). |
| 39 | M&L for taking out old unserviceable change over switch and Supply and fix Automatic Change over switch / Automatic transfer switch in sheet steel enclosure duly powder coated of Capacaity 400 Amps, 4 pole with complete protection, controller and having provision of manual operation also suitable for 415 volt , 50 Haz AC supply. The ATS shall be fixed on wall on a angle iron frame made out of angle iron 50x50x6 mm angle and cable end boxes on top and bottom (the height of cable end boxes shall be minimum 450 mm) all as specified and as directed by Engineer-in-Charge. (Havells Cat No IHYFCDE400 or same type in L&T/Siemens/ABB/ Schneider) |
| 40 | M&L for taking out old unserviceable change over switch and Supply and fix Automatic Change over switch / Automatic transfer switch in sheet steel enclosure duly powder coated of Capacaity 200 Amps, 4 pole with complete protection, controller and having provision of manual operation also suitable for 415 volt , 50 Haz AC supply. The ATS shall be fixed on wall on a angle iron frame made out of angle iron 50x50x6 mm angle and cable end boxes on top and bottom (the height of cable end boxes shall be minimum 450 mm) all as specified and as directed by Engineer-in-Charge. (Havells Cat No IHYFCDE200 or same type in L&T/Siemens/ABB/ Schneider) |
| 41 | M&L for conductive concrete Earth grid of multiple interconnected Earth Electrodes to achieve the earth resistance value of less than <5 ohm. The excavation is to be carried out in any type of soil including hard rock. The approx specification are as under:-(i) Earth Electrodes: Metal conductor - Copper bonded MS rod dia 17.2 mm (+/-5mm). Length 2.25 meter with conductive concrete including provision of bore 65 mm dia, 2.25 meter length of earth electrode.(ii) All earth electrode (min two Nos) should be installed to achieved the desired result.(iii) Interconnected strip: All the multiple Earth Electrodes will be horizontally interconnected with metal conductor-Copper strip flat size : 25mm x 3mm & conductive concrete embedding size 60 mm Sqmm.(iv) Test Link: Test links - Copper strip flat size 40mm x 6mm x 200 mm shall be provided, at any one of the multiple Earth Electrodes of the grid for connection betwee earth grid pit and application.(v) Pit Cover: RCC pit cover & frame shall be provided at all Earth Electrode (with test links). |
| 42 | Supply, installing, testing and commissioning factory made and tested AMF Panel 200 KVA with Bypass arrangement for Main & DG supply INDOOR type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. The panel shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Mounting Channel work made out of 75 mm ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. The scope of work also comprising of the following:- (a)Under Voltage relay 415V AC for main -1 No.(b) Under voltage relay 415 V AC for DG - 1 No.(c) AC Timer 230 Volt , 2 No. +2 NC - 1 No.(d) DC Timer 12/24 V - 1No.(e ) Engine Starting relay 12/ 24 V- 1 No(f) Control MCB SP 6 Amp. 230 V – 9 Nos.(g) Control MCB SP 16 Amp. 230 V – 2 Nos.(h)Battery Charger 12/24 DC - 1 No. (j) LED Indicating Light for Main & DG—6 Nos(k) LED Indicating Light for Main & Gen. ON – 2 Nos. (l) LED Indicating Light for battery Charger –1 No.(m) Digital Volt meter ( 0-500 V ) Flush Mounted 96 mm X 96 mm - 1 No. (n) Digital Amp meter ( 0-250 A ) Flush Mounted 96 mm X 96 mm - 1 No. (o)Volt Meter Selector switch 6 A - 1 No. |
| 43 | Contd…./-(p) Ampere Meter Selector switch 6 A - 1 No. (q) CT Coil 250/5 A CL-1 - 3 Nos.(r)DC Volt Meter 15/30 V analog type - 1 No.(s) DC Amp Meter 0-15 A analog type - 1 No.(t) Trickle / Boost switch –2 Nos.(u) Auto / Manual Selector Switch ---1 No.(v)Start & Stop Push Button - 2 Nos.(w) Digital Frequency Meter 45-55Hz–1 No.(x) Hooter 12/24 V DC - 1 No.(y) Power Contactor 255 Amps 4 Pole having coil voltage 415 V AC for DG Supply - 1 No.(z) Power Contactor 255 Amps 4 Pole having coil voltage 415 V AC for Main Supply - 1 No.(aa) Incoming MCCB 250 Amps 415 V AC 25 KA 4 Pole Fixed Thermal Magnetic release for Main & DG Supply - 2 Nos.(ab) Control Relay - 1 Set. (ac) Over Load relay 3-5 A - 1 No.(ad) On Load Change Over Switch 250 A 4 Pole Open execution For Bye Pass Main Supply - 1 No.(ae) On Load Change Over Switch 250 A 4 Pole Open execution For Bye Pass DG Supply - 1 No.(af) Interconnecting Aluminium Link from MCCB to Contactors with incoming & Outgoing- 1 Set. |
| 44 | Supply, installing, testing and commissioning factory made and tested AMF Panel 400 KVA with Bypass arrangement for Main & DG supply INDOOR type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. The panel shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Mounting Channel work made out of 75 mm ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. The scope of work also comprising of the following:- (a)Under Voltage relay 415V AC for main -1 No.(b) Under voltage relay 415 V AC for DG - 1 No.© AC Timer 230 Volt , 2 No. +2 NC - 1 No.(d) DC Timer 12/24 V - 1No.(e ) Engine Starting relay 12/ 24 V- 1 No(f) Control MCB SP 6 Amp. 230 V – 9 Nos.(g) Control MCB SP 16 Amp. 230 V – 2 Nos.(h)Battery Charger 12/24 DC - 1 No. (j) LED Indicating Light for Main & DG—6 Nos(k) LED Indicating Light for Main & Gen. ON – 2 Nos. (l) LED Indicating Light for battery Charger –1 No.(m) Digital Volt meter ( 0-500 V ) Flush Mounted 96 mm X 96 mm - 1 No. (n) Digital Amp meter ( 0-250 A ) Flush Mounted 96 mm X 96 mm - 1 No. (o)Volt Meter Selector switch 6 A - 1 No. |
| 45 | Contd…./-(p) Ampere Meter Selector switch 6 A - 1 No. (q) CT Coil 250/5 A CL-1 - 3 Nos.(r) DC Volt Meter 15/30 V analog type - 1 No.(s) DC Amp Meter 0-15 A analog type - 1 No.(t) Trickle / Boost switch –2 Nos.(u) Auto / Manual Selector Switch ---1 No.(v) Start & Stop Push Button - 2 Nos.(w) Digital Frequency Meter 45-55Hz–1 No.(x) Hooter 12/24 V DC - 1 No.(y) Power Contactor 255 Amps 4 Pole having coil voltage 415 V AC for DG Supply - 1 No.(z) Power Contactor 255 Amps 4 Pole having coil voltage 415 V AC for Main Supply - 1 No.(aa) Incoming MCCB 250 Amps 415 V AC 25 KA 4 Pole Fixed Thermal Magnetic release for Main & DG Supply - 2 Nos.(ab) Control Relay - 1 Set. (ac) Over Load relay 3-5 A - 1 No.(ad) On Load Change Over Switch 250 A 4 Pole Open execution For Bye Pass Main Supply - 1 No.(ae) On Load Change Over Switch 250 A 4 Pole Open execution For Bye Pass DG Supply - 1 No.(af) Interconnecting Aluminium Link from MCCB to Contactors with incoming & Outgoing- 1 Set. Please Enable Macros to View BoQ information |