| 1 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285,fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including dash fasteners, cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.For fixed portion: Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including dash fasteners, cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 3 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 4 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in- charge.Pre-laminated particle board with decorative lamination on both sides |
| 5 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width |
| 6 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 7 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200 mm |
| 8 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. Note: Only the following makes are approved, as per the directions of the Engineer-in-Charge – Godrej, Hafele, Ozone, and Dorset. |
| 9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge: SS Tower Bolts 250x10mm |
| 10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge: SS Door stopper 75mm |
| 11 | Supplying, installing, testing, and commissioning of precision sliding roller system for Aluminium Door, suitable for door openings up to 1.50 m width and 2.40 m height, complete with track channel, rollers, guides, stoppers, and all necessary fittings, designed to support the total load as per site conditions. The system shall be of approved make such as Hettich / Hafele / Ozone, or other equivalent make as approved by the Engineer-in-Charge. The work shall be executed strictly in accordance with manufacturer’s specifications, complete in all respects, including supply of all materials, installation, alignment, finishing, labour, tools, testing, commissioning, and all incidental charges, as directed by the Engineer-in-Charge. |
| 12 | Providing and fixing self-adhesive frost film of approved make, shade, and pattern, suitable for application on glass or acrylic partitions. The work includes cleaning of the surface, precise cutting of the film to required dimensions, fixing with pressure-sensitive adhesive backing, removal of air bubbles using appropriate tools, and neat edge finishing, all complete as per manufacturer’s specifications and as directed by the Engineer-in-Charge. The item shall be measured on the basis of the actual area of film applied (in square metres). |
| 13 | Providing and laying 3 mm thick epoxy flooring, consisting of epoxy resin and binder of approved make, to form a rigid and durable surface in approved colours (Blue, Grey, and Light Blue etc.,), including all materials, labour, and incidental charges, complete as per specifications and as directed by the Engineer-in-Charge. |
| 14 | Providing and laying epoxy coving up to 150 mm radius, as required, at the junction of wall and floor, consisting of epoxy resin and hardener/binder of approved make, with or without epoxy mortar filler as required, to form a rigid and durable surface in approved colours (Blue, Grey, and Light Blue etc.,), including thorough surface preparation, application of primer/bonding coat, finishing to smooth profile, curing, protection, and all incidental works, complete in all respects as per manufacturer’s specifications and as directed by the Engineer-in-Charge. |
| 15 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) |
| 16 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of 8mm thick Cement Fibre Board (Board with BIS certification marks) to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 8mm thick Cement Fibre Board (Board with BIS certification marks) |
| 17 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Platform/Base for Equipments /Machines, Foundations, footings, bases of columns, Columns etc. |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete below plinth level and above plinth level upto floor V level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 21 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 22 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works below plinth level and above plinth level up to floor V level shall be executed in M25 grade concrete with a minimum cement content of 330 kg /cum. |
| 23 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand) |
| 24 | Drilling holes of diameter up to 32 mm in reinforced or plain cement concrete using a power-driven drill machine, to a depth of up to 250 mm in RCC platforms, bases, beams, lintels, columns, and slabs, for insertion of anchor bolts; including fixing the anchor bolts in position with epoxy resin anchor grout of approved make, but excluding the cost of anchor bolts, complete as directed by the Engineer-in-Charge. |
| 25 | Structural steel work riveted, bolted, or welded in built-up sections, trusses, and framed work, including cutting, hoisting, fixing in position, and applying a priming coat of approved steel primer, and painting with synthetic enamel paint of approved brand and manufacture to give an even shade, with two or more coats on new work, all complete as per the direction of the Engineer-in-Charge. |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes |
| 28 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 29 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15 mm nominal bore |
| 30 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe- 40 mm dia |
| 31 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe- 40 mm dia |
| 32 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460 mm bowl depth 200 mm |
| 33 | Providing and fixing of PVC pipes 75mm dia., 6 kg/sqcm & class 3. This includes jointing of pipes & all fittings with PVC solvent and testing of joints complete as per direction of Engineer in Charge. |
| 34 | Providing and fixing 100 mm dia PVC Nahani Trap of approved quality, including necessary cutting, jointing, sealing, and making good the surfaces, all complete as per the direction of the Engineer-in-Charge. |
| 35 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge, with 6mm thick toughened glass. |
| 36 | Providing and fixing Laboratory Sink, Polypropylene, 60 x 45 x 30 cm including making all connections excluding cost of fittings. Please Enable Macros to View BoQ information |