|
| 1 | Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201 |
| 2 | Compacting original ground supporting subgrade (Loosening of the ground upto a level of500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction.) |
| 3 | Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) |
| 4 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.With Grading-I Material |
| 5 | Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 |
| 6 | Providing and fixed of retro- reflecrorised cautionry, mandatory and informtro sing as par IRC :67 made of high intensity grade sheeting vide clause 801:3 fixed over aluminum sheeting, 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x 6 mm firmly fixed to the ground by means of properly desinded foundation with M15 grade cement concrete 45 cm x 6 cm , 60 cm below ground level as par approved drawing 80, 80 mm x 60 mm rectangular |
| 7 | Direction and Place Identification signs with size more than 0.9 sqm size board (Providing and erecting direction and place identification retro- reflectorised sign asper IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) |
| 8 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. |
| 9 | Construction of dry rubble flooring at cross drainage works for relatively less important works. |
| 10 | Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.(P.C.C. Grade M-15) |
| 11 | Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specificationsCoarse Rubble Masonary in C.M. (1:3) in sub-structure |
| 12 | Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications.Square Rubble Coursed Rubble Masonry (1st sort) in C.M. (1:3) |
| 13 | Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical speciofications(P.C.C. Grade M-15) |
| 14 | Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical speciofications(P.C.C. Grade M-20 in Cover Slab) |
| 15 | Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical speciofications(P.C.C. Grade M-25 in Deck Slab) |
| 16 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications |
| 17 | Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications |
| 18 | Plastering with cement mortar (1:3) on brick work in substructure as per technical specifications |
| 19 | Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications. |
| 20 | Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications.Random Rubble Masonry Work in Cement Mortar 1:3 in foundation |
| 21 | Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specificationsRandom Rubble Masonry Work in Cement Mortar 1:3 in S/S |
| 22 | Backfilling behind abutment, wing wall and return wall with Sandy Material complete as per drawings & technical specification Clause 1204.3.8(With Sandy Material) |
| 23 | Painting Two coats on New Concrete Surfaces (Painting Two Coats after filling the Surface With Synthetic Enamel paint in all Shades on New Plastered comcrete Surfaces |
| 24 | Pointing with cement mortar (1:3) on brick work in substrucutre as per technical specifications |
| 25 | Goods & Service Tax (G.S.T.) - |
| 26 | Labour Cess - Please Enable Macros to View BoQ information |