Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 3 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 4 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared |
| 5 | Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge. |
| 6 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes75 mm diametre |
| 7 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Bend 87.5°12.59.5.1 75 mm bend |
| 8 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 9 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 1 meter from cutting edge All kinds of soil |
| 10 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil |
| 11 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.Ordinary Rock |
| 12 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 13 | Supply of Stone boulder (nallah) nominal size 225 mm (Stack measurements reduced by 15%) |
| 14 | Dumping stone excluding cost of stones.in Horizontal on level |
| 15 | Silt clearance from canals. Inclusive of initial lead and lift ( 50m & 1.5m respectively ) Wet |
| 16 | Carriage for disposal of silt/sludge by Manual means avg 150 mtr |
| 17 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of soil : |
| 18 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil : |
| 19 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge Ordinary rock |
| 20 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 21 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : Ordinary rock |
| 22 | Preparation of subgrade by excavating earth to an average of 22.5 cm depth, dressing to camber and consolidation with road roller of 8-12 tonne capacity including making good the undulation etc. and disposal of surplus earth upto 50 meters |
| 23 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20 |
| 24 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge |
| 25 | Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). Depth exceeding 1.5 m but not exceeding 3 m |
| 26 | P/L of dry stone soiling in horizontol on level |
| 27 | P/L of stone soiling including ramming, consolidating and levelling All complete |
| 28 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 29 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 30 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 31 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 32 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 33 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 34 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 35 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) |
| 36 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 37 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V leveL |
| 38 | Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. |
| 39 | Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein. |
| 40 | Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge. 16.63.1 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.5% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity |
| 41 | Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface and cleaning with mechanical broom. On bituminous surface @ 0.25 Kg/sqm. |
| 42 | Providing Fixing of neoprene bridge beraings / elastomeric bearings pads for bridge for Vibration, hardness: 70-80 thickness 600 mm |
| 43 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 44 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete |
| 45 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
| 46 | Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc. |
| 47 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
| 48 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms |
| 49 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 50 | Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 51 | Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars, piers, abutments, posts and struts. |
| 52 | Centering and shuttering including strutting, propping etc. and removal of form for: Arches, domes, vaults upto 6 m span |
| 53 | Centering and shuttering including strutting, propping etc. and removal of form for Extra for arches, domes, vaults exceeding 6 m span |
| 54 | Arches, Domes, Vaults upto 6mtr span |
| 55 | Extra for Arches, Domes, Vaults exceeding 6mtr span |
| 56 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 57 | Centering and shuttering including strutting, propping etc. and removal of form for: Spiral staircases (including landings) |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars, piers, abutments, posts and struts. |
| 59 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). 5.11.1 Suspended floors, roofs, landings, beams and balconies (plan area to be measured) |
| 60 | Suspended floors, roofs, landings, balconies and access platforms |
| 61 | Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 62 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 63 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 64 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 65 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 66 | Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. One coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge |
| 67 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand |
| 68 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 69 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm) 18mm |
| 70 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite Work |
| 71 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 72 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 73 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 74 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 75 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 76 | Wooden planking, tongued and grooved in flooring including fixing with iron screws complete: 11.43.1 12 mm thick Second class teak wood |
| 77 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick |
| 78 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats |
| 79 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 80 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 81 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. 11.50.1 In colour such as White, Ivory, Grey, Fume Red Brown |
| 82 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood |
| 83 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. First Class kail wood |
| 84 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 85 | Providing and fixing ball bearing for rolling shutters. |
| 86 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required |
| 87 | Group B |
| 88 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required |
| 89 | 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 90 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 91 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 92 | Supplying and fixing of following sizes/modules, GI box along with modular base and covber plate for modular switches in recess etc as required |
| 93 | 6 Module |
| 94 | 4 Module (125mmX75mm) |
| 95 | 12 Module (200mmX75mm) |
| 96 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but existing modular plate etc. as required |
| 97 | 5/6 A switch |
| 98 | 3 pin 5/6 A socket outlet |
| 99 | 15/16 A switch |
| 100 | 6 pin 15/16 A socket outlet |
| 101 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 102 | Supplying and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 103 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 104 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 105 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep |
| 106 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required |
| 107 | 32A TP&N |
| 108 | 63A TP&N |
| 109 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 110 | 6 way, Double door |
| 111 | Providing & Installing 8W Round Led Ceiling Light Complete Job |
| 112 | Providing & Installing Exaust fan incl. all fittings |
| 113 | Providing & Installing 8W Round Led Ceiling Light Complete job. |
| 114 | Providing & Installing 200mm Exhaust Fan| Cut Out Size: 9.4x9.4 square inches| Watt: 32| RPM: 1350| Air Delivery: 520| Suitable for Kitchen, Bathroom, and Office |
| 115 | Providing & Installing Electric Ceiling Fan | 1200mm BEE Star Rated Ceiling Fan |
| 116 | Providing and fixing Inverter & Battery (Eco Watt Neo 900 Square Wave 600VA/12V Inverter with Red Charge RC 15000ST Short Tubular 150Ah Battery) |
| 117 | Clariflaculator : Design & Supply insallation and testing & Commissioning & Commissioning including packing, handling, transportation, insurance, storage of Complete Mechanical System required for Clarifloculater for the following WTPs.This will generally consist of elecrically driven mechanical scrapping arrangement, electrically driven peddles for flocculation tank, Current collectors motors etc having complete in all respectsFlocculator Size = 9.0M Dia.Clarifier Size = 26 m Dia.Depth = 4.5 mtr.Rotating Bridge Structure:The rotating arms of the bridge structure shall incorporate a walkway having a minimum effective width of 1200 mm which shall be surfaced with Aluminum Chequered plates,. The bridge shall be lattice girder designed to take its own dead weight together with uniformly distributed loading of minimum 250 kg/sq.cm over the full span and width of the walkway bridge and a moving point load of 500 kg. Maximum deflection of the bridge under the specified loading shall not exceed 1/360th of the span. The positive camber shall be kept initially to compensate for the maximum deflection under dead weight and superimposed loads. The bridge shall be so braced as to limit lateral deflection to less than 80 mm measured at mid span under a full load condition. The central part of the bridge shall be large enough for the installation of the Flocculator systems and the control panel. The bridge shall have hand railing to both sides forming an enclosure in between. The finished height of the railing shall be 1.0 m above the walkway |
| 118 | Flash Mixing System : Design & Supply insallation and testing & Commissioning including packing, handling, transportation, insurance, storage of Flash Mixing System consisting of Agitator assembly, Reduction Worm Gear, with motor etc. complete in all respects and suitable for tank size: Dia -1.6m depth 2.8 max |
| 119 | Alum Mixing System : Design & Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of Alum Mixing System consisting of Agitator assembly, Reduction Worm Gear, motor etc. complete in all respects and suitable for tank having following size:size of tank - Dia 1.6 m x Depth 2.8 m |
| 120 | Air Blower: Design & Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of blower twin lobe with V-belt or direct, acoustic hood, Inlet filter-silencer, discharge silencer, PRV, NRV, pressure gauge, flow indicator, VFD optional, & Interlock with backwash; sequence air 6-9 min, then air-water/water, pressure relief valve complete piping & specials, enlargers/reducers, pressure gauge, etc. complete with all other required accessories and of the following capacities:( Capacity: 466+ CFM, Pressure: 0.40Kg/cm2 , Riating of motor 25 HP) |
| 121 | Flow Measuring : Design & Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of suitable type Electro-magnetic type Flow meters complete in all respects for measuring Clear Water from CWR and suitable for following pipes. 450mm dia pipe Range 0 to 0.6LPS |
| 122 | Backwash pump motor unit: Design & Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of Centrifugal Horizantal end Suction pump motor unit having suction head upto 5 mtrs, discharge head upto 20 Mtrs & should have discharge 15 L/S with valve assembly complete in all respects with 3 Phase motor 7.5 HP |
| 123 | Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of Sluice Valve CI/ DI DF drilled hoes as per IS:14846 of diameter 450 mm with complete spindle rods of required height & head stock. |
| 124 | Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of Sluice Valve CI/ DI DF drilled hoes as per IS:14846 of diameter 300 mm complete in all respects |
| 125 | Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of Sluice Valve CI/ DI DF drilled hoes as per IS:14846 of diameter 250 mm complete in all respects |
| 126 | Supply insallation and testing & commissioning including packing, handling, transportation, insurance, storage of Sluice Valve CI/ DI DF drilled hoes as per IS:14846 of diameter 200 mm complete in all respects |
| 127 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Sluice Valve CI/ DI DF drilled hoes as per IS:14846 of diameter 100 mm with complete spindle rods of required height & head stock. |
| 128 | Supply installation and Comissioning of flow control system with ultra sonic loss of head and rate of flow measuring digital meters for 3 no. filter beds including required cable panelcomplete in all respects. The flow rate with units is diaplayed on the upper line of LED display and the totalizer flow is displayed on 8/10 digits on second line. The differential control system consists of ultra sonic transmitters and differential level controller. The flow control system including all the equipments required in outlet chamber of clear water for controlling the rate of flow |
| 129 | Supply & Installation of 1 Ton capacity Chain pulley block, having lifting height 2 mtrs with chain for Air Blower complete with steel frame structure. |
| 130 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Equal Tee MS DF drilled hoes as per IS 13159-1 of diameter Ø(450 x 450 x 450) mm complete in all recpects |
| 131 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Reduced Tee MS DF drilled hoes as per IS 13159-1 of diameter Ø(450 x 450 x 200) mm complete in all recpects |
| 132 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Equal Tee MS DF drilled hoes as per IS 13159-1 of diameter Ø(300 x 300 x 300) mm complete in all recpects |
| 133 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Equal Tee MS DF drilled hoes as per IS 13159-1 of diameter Ø(250 x 250 x 250) mm complete in all recpects |
| 134 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Reduced Tee MS DF drilled hoes as per IS 13159-1 of diameter Ø(250 x 250 x 100) mm complete in all recpects |
| 135 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Bend 90 Degree 300mm DF drilled hoes as per IS 1239/9523 complete in all recpects |
| 136 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Bend 90 Degree 250mm DF drilled hoes as per IS 1239/9523 complete in all recpects. |
| 137 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Bend 90 Degree 200mm DF drilled hoes as per IS 1239/9523 complete in all recpects |
| 138 | Supply, Installation including packing, handling, transportation, insurance, storage and inspection & testing at at site of Bend 90 Degree 100mm DF drilled hoes as per IS 1239/9523 complete in all recpects. |
| 139 | Supply, and fixing including handling, transportation, storage at site of MS pipe of diameter 450mm with thickness 5mm etc as per IS 1239/9523 complete in all recpects. |
| 140 | Supply, and fixing including handling, transportation, storage at site of MS pipe of diameter 300mm with thickness 4.85mm etc as per IS 1239/9523 complete in all recpects |
| 141 | Supply, and fixing including handling, transportation, storage at site of MS pipe of diameter 250mm with thickness 4 mm etc as per IS 1239/9523 complete in all recpects. |
| 142 | Supply, and fixing including handling, transportation, storage at site of MS pipe of diameter 200mm with thickness 4 mm etc as per IS 1239/9523 complete in all recpects. |
| 143 | Supply, and fixing including handling, transportation, storage at site of MS DF pipe of diameter 100mm of Class C as per IS 1239/9523 complete in all recpects. |
| 144 | Supply, and fixing including handling, transportation, storage at site of MS Langes for pipe jointing with welding of diameter 450mm with nuts/bolts etc as per IS 13150:1993 complete in all recpects |
| 145 | Supply, and fixing including handling, transportation, storage at site of MS Langes for pipe jointing with welding of diameter 300mm with nuts/bolts etc as per IS 13150:1993 complete in all recpects |
| 146 | Supply, and fixing including handling, transportation, storage at site of MS Langes for pipe jointing with welding of diameter 250mm with nuts/bolts etc as per IS 13150:1993 complete in all recpects |
| 147 | Supply, and fixing including handling, transportation, storage at site of MS Langes for pipe jointing with welding of diameter 200mm with nuts/bolts etc as per IS 13150:1993 complete in all recpects |
| 148 | Supply, and fixing including handling, transportation, storage at site of MS Langes for pipe jointing with welding of diameter 100mm with nuts/bolts etc as per IS 13150:1993 complete in all recpects |
| 149 | Electrical Panel :- Design & Supply including Packaging, Handling, Transportation, Insurance, Storage and Inspection & Testing at the manufacturer's works) of LT panel suitable for operation on 415 V, 3 phase , 50 Hz, alternating current, indoor type, sheet steel clad, dust and vermin proof, totally enclosed, floor mounting, single front, fixed type and compartmentalized, extensible on both sides, epoxy resin powder coated painted provided with aluminum bus- bars, one panel heater, cable terminations of all incoming and outgoing cables, voltmeters, amperemeters, frequency meter, power factor meter and comprising of following incoming & outgoing feeders: Incoming feeder fitted with drawout type M.C.C.B of suitable capacity and change over switch of suitable rating complete with thermal overload and instantaneous electromagnetic short circuit relays. Outgoing feeder for motor, complete with suitable MCCB for air blower 100 Amps 2nos, Backwash motor 25 Amps -2no, Clariflaculator 20Amps -1no, Flash mixer motor 10 Amps -1no type star deta starters for pump motor complete in all respects. 2 nos MCCBs lighting and auxiliary 63 amp, 32 amp spare each |
| 150 | Earthing :- Supply and fixing including Packaging, Handling, Transportation, Insurance, Storage and Inspection & Testing at site of earthing grid for all electrical equipment's, with earth plates of suitable sizes including earthing strips, accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. , charcoal and salt for earth electrode complete in all respects.(i)Providing and fixing 25mm x 5mm aluminum strip in 40mm dia pipe from earth electrode to Panel etc. (ii) Fixing 25mm x 5mm aluminum strip on surface or in recess for connection etc. as required, all as specified for connecting of electrical accessories for all required Equipments |
| 151 | Cable LT: Design & Supply (including Packaging, Handling, Transportation, Insurance, Storage and Inspection & Testing at the manufacturer's works) of LT XLPE/ PVC insulated sheathed armoured cable r of required sizes from Panel to Flash mixer , Clariflaculator and Backwash motor etc 3C x 4 Sqmm Cu |
| 152 | Cable LT: Design & Supply (including Packaging, Handling, Transportation, Insurance, Storage and Inspection & Testing at the manufacturer's works) of LT XLPE/ PVC insulated sheathed armoured cable of required sizes from Panel to Air blower motor and Electrical lighting etc 3.5C x 25 Sqmm Al |
| 153 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete 50 mm thick with 20mm nominal size stone aggregate |
| 154 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 155 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 156 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 157 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms |
| 158 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge. |
| 159 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work |
| 160 | Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 161 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like |
| 162 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6mm for diagonal braces |
| 163 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece. |
| 164 | Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement) |
| 165 | Providing weep holes in brick masonary / plain/reinforced concrete abutment, wing wall/return wall with 100mm dia PVC pipe, extending through the full width of the structure with slope towards drawing face. Complete as per drawing and technical specifications |
| 166 | Collection, supplying, filling and leveling stone boulders of size 50mm to 200mm behind retaining walls including carriage by mechanical / headload complete as per directions of engineer in charge |
| 167 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 80 mm nominal bore |
| 168 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 65 mm nominal bore |
| 169 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm |
| 170 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 171 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required Stainless Steel AISI- 304 (18/8) Orissa pattern W.C. pan of size 585x480mm with flush pipe and integrated type foot rests |
| 172 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood |
| 173 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second kail wood 30mm thick |
| 174 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick Second Class kail wood |
| 175 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) |
| 176 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 177 | Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 75x63x3.2 mm |
| 178 | Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x63x3.2 mm |
| 179 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm |
| 180 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm |
| 181 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm |
| 182 | Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge 22.16.1 Anodized (AC 15) aluminum |
| 183 | Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge 22.16.1 Anodized (AC 15) aluminum |
| 184 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 185 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 9.40.1 2nd class teak wood 9.40.1.1 50 x 12 mm |
| 186 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-inchargePN-16 pipe , 32mm OD(SDR-7.4) |
| 187 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. 19.2.1 Internal work-exposed on wall with clamps at 1.00 meter spacing 19.2.1.1 PN-16 pipe, 16mm OD(SDR-7.4) |
| 188 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. 19.2.1 Internal work-exposed on wall with clamps at 1.00 meter spacing 19.2.1.1 PN-16 pipe , 20mm OD(SDR-7.4) |
| 189 | Providing and installing uPVC pipes (working pressure 4 kg /cm2) Single socketed pipe 110 mm dia with all necessary arrangments and fitings including Tee's, elbows and end caps whereever required complete job |
| 190 | Supplying and fixing C.I. cover without frame for manholes: 20.14.1 455x610mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg |
| 191 | Providing and fixing brass bib cock of approved quality. 20 mm nominal bore |
| 192 | Providing and fixing brass stop cock of approved quality. 20 mm nominal bore |
| 193 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 18.3.1 W.C. pan with ISI marked white solid plastic seat and lid. |
| 194 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 18.1.1 DELETED 18.1.2 White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 195 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Surgeon type wash basin size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers |
| 196 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings |
| 197 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm dia |
| 198 | Providing and fixing water trap for wash basin or sink |
| 199 | Providing and fixing stainless floor drain trap / jali with cockroach trap all accessories complete job |
| 200 | Providing and installing 25 ltr geyser / water hetaer with all necessary arrangements complete |
| 201 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia |
| 202 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 203 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 204 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete |
| 205 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 18.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 206 | Providing and fixing square mouth S.W. gully trap 100 x 100 mm size P type |
| 207 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040mm bowl depth 200mm |
| 208 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x460mm bowl depth 200mm |
| 209 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete With 2nd class teak wood beading 62x19 mm |
| 210 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m |
| 211 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete |
| 212 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 213 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 100 mm dia. nominal bore |
| 214 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 150 mm dia. nominal bore |
| 215 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Class II 100mm dia |
| 216 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Class II 150mm dia |
| 217 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. (At crown of OHT bird proof wire mesh) |
| 218 | Centering and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral staircases. |
| 219 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 220 | 12mm Cement plaster finished with a floating coat of neat cement of mix: 13.7.1 1 : 3 ( 1 cement : 3 fine sand) 13.7.2 1 : 4 ( 1 cement : 4 fine sand) |
| 221 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Class II 300mm dia |
| 222 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Class II 250mm dia |
| 223 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Class II 200mm dia |
| 224 | P/F MS pipe confirming TO IS:3589 for washout, overflow, inlet delivery outlet 300mm dia |
| 225 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 226 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 227 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 228 | Miscellanous sanitary. Installation like grating, soap dish holder 02 no's, extension nipple for water tank pipe, water tank connection, cost of 1000 ltr PVC tank, Electric motor, G.I pipes 15mm dia Heavy duty and allied fittings (Tee, union, Nipple, plug etc.) and labour for cutting walls and fixing of all fittings, accesories, squatting pan, wash basins etc. in bathroom near Pump Room/Ch Qtr ( complete job) |
| 229 | Providing and fitting concealed Electrification of operator room including kitchen, bathroom, verandah etc. (complete job) i.e. LED lights = 10 Nos including Fuse box 1 No. Main switch (with complete wiring and switches), 4 no 15 Amp sockets , 5 Amp 5 no. sockets, 01 no fan, etc as per BIS standards ( as per directions of Engineer- In-charge) |
| 230 | Finishing of Kitchen i.e Sink, Marbel on Shelves, Tile work in floor and cooking area, C.P brass bib cock 02 Nos, C.P brass angle valves 02 nos including all G.I pipe fitting and nesessary items (complete job) |
| 231 | Removal of Filter media from filter chamber, cleaning bleach dozer tank and alum tank etc. |
| 232 | Repair to electric motor for bleach tank and Alum Tank assembling making it fully functional and back wash tank and monoblock/ pump |
| 233 | Providing and fixing electric motors for clarifloculation making fully functional |
| 234 | Providing and fixing mushroom valve making it fully functional (300mm dia) |
| 235 | Providing and fixing of air blower capable for providing compression @ 225 cum per minute @ 0.35 kg/Sqm with suitable 3 phase induction motor with auxilary pipe system upto filter bds fitting prssure guge nozzels cement black base plate air check valves, non return valves, cement conc black in M-20 grade foundation bolt base frame fabricated out at 100mm MS channels, the job also includes PRV Pipe and Pipe fittings shurters and PVC 19/28 coper wive complete job & other elctrical controlling devices fitted on panel board complete Job |
| 236 | Providing and fixing of MS rotating bridge fabricated IS 65x65x6mm angle suitable for bearing silt of Clariflocculator (dia) 6.0 m. The Job including cerival bearing assembly shaft and MS Wheels, Stop Wheels and deflector draft tube fabricated out of MS Sheet with Proper Proforatin as per site requrement, including placing in position with adequate rotating prime moves 3 phase 440 volt 50Hz inc. fly sheel and MS rail, on fish plate grouted on top base of PST in cement concrete. The Job ncludes provding and installation of 3 phase cubical electrical panel 63 Amp capcity with appropriate ratingt 3 hase MCCB/OCB and Automatic panel of electrical motors incl. connecting eith electrical PVC copper cable and on poll system. The Job includes fabriation and fitting f scraper blades fabricated out of 65x65x6mm angle & 3mm thick sheet including assembly with rotating system and central shaft. For 03 No's F/Plants |
| 237 | Provding and fitting of Automated bleaching doser pum along with all necessary acesseries inc; Provision for constant dozing of bleaching along with required arrangement i.e motor, switches, starter/Autmatic panel etc. (complete Job) along with stand by unit. For 02 No's F/Plants |
| 238 | Provding installation testing commissioning of 100 Amp dust/ moisture Proof cubical pannel fitted with 3 hase 100 Amp MCCB l&T make 02 no. and 65 Amp single phase MCCB fr lighting and heating systems. The job also includes no. amp metre 0.100 AE make with CT coips and one number voltmetre AE make 0.500 with selector switches, L&T make and 3 No. indicator lamps Neon tyupe complete Job. |
| 239 | Providing installation testing commissioning of 3 phase oil immersed 30 KVA voltage stabilizer (servo make) capable to perate incoming voltae of 180 volt and outgoing voltage at 410+-10% volt complete Job |
| 240 | Providing and fixing of flood light (Havels or crompton) |
| 241 | Providing, stacking and Filling of graded stone agg. (Filter Media) of size 1.5 -4mm, 6-12mm, 12-20mm, 20-40mm, 40-65mm in five layers (Nallah) including carriage from source to be indentified by Engineer Incharge. |
| 242 | Supply of Silica sand as filter media of size 0.45 mm-0.7 mm having uniform co-efficient 1.3-1.75 and should be free from dust and other organic and inorganic impurities including carriage from source i.e Calcutta west Bengal |
| 243 | Finishing walls with water proofing cement paint of required shade: 13.117.1 Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @ 0.80 liters/10sqm complete including cost of priming coat. |
| 244 | Repair to electric fitting in filter plant chemical house includes fitting of switches, main switch, fuse box 1no, sockets 15 Amp no. 5Amp. 3 no, MCB 1 no, 12 Amp LED lights |
| 245 | PVC pipe 20mm for alum and bleach tank 20mm |
| 246 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of selfhealing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage. 23.19.1 For vertical surface two coats @ 0.70 kg per sqm |
| 247 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of selfhealing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm. |
| 248 | Providing installation testing commissioning of monoblock pumping equipment capable of lifting of 35 cum per hour for a height at 20 m with 3 phse appropriate rate power induction moves with sturter assembly suction and delivery pipe and pipe fittings of required sec. upto back was tank, the job inc; all eclectrical operating devices fitted on pannel borad along with stand by motor |
| 249 | Renewing glass panes, with putty and nails wherever necessary including raking out old putty : 14.6.1 Float glass panes of thickness 4.0 mm(weight not less than 10kg/sqm) |
| 250 | Carriage of cement including loading, unloading and stacking by Manual means avg 500 mtr |
| 251 | Carriage of steel including loading, unloading and stacking by Manual means avg 500 mtr |
| 252 | Carriage of sand from source to site of work including loading, unloading and stacking by Mechanical Transport avg lead 60 km & by Manual means avg 500 mtr |
| 253 | Carriage of stone aggregate below 40mm nominal size from source to site of work including loading, unloading and stacking by Mechanical Transport avg lead 10 km & by Manual means avg 500 mtr |
| 254 | Carriage of bricks from Jammu brick kiln to site of work including loading, unloading and stacking by Mechanical Transport avg lead 70 km & by Manual means avg 500 mtr |
| 255 | Carriage of soiling stone from source to site of work including loading, unloading and stacking by Mechanical Transport avg lead 20 km & by Manual means avg 500 mtr |
| 256 | Carriage of soiling stone from source to site of work including loading, unloading and stacking by Manual means avg 750 mtr |
| 257 | Carriage of Cement from division head quarterf from source (to be identified by engineer in charge) to site of work /dumping place (To be identified by engineer in charge)including cost for loading and unloading.for an av. distance by Mechanical Transport 10 Km and H/L 50 m |
| 258 | Carriage of Cement including cost for loading and unloading.for an av. distance by Manual means 300 mtr |
| 259 | Carriage of Bajri from source (to be identified by engineer in charge) to site of work/dumping place (To be identified by engineer in charge) including cost for loading and unloading for an av. distance of MT 20 Km and H/L 50 m |
| 260 | Carriage of Sand from source (to be identified by engineer in charge) to site of work/dumping place (To be identified by engineer in charge) including cost for loading and unloading for an av. distance of MT 70 Km and H/L 50 m |
| 261 | Carriage of Sand consisting of inert and durable sand grains frees of clay, loams and organic matter of effective size of 0.25 mm to 0.35mm with uniform coefficient of 3.0 -5.0 from Ganderbal Kashmir.and stone aggregate upto 20mm from source (to be identified by engineer in charge) to site of work/dumping place (To be identified by engineer in charge) including cost for loading and unloading.for an av. distance of MT 310 Km and H/L 50 m |
| 262 | Carriage of graded stone agg. (Filter Media) of size 1.0 -1.5mm, 4-6mm, 15-25mm in four layers (Nallah) including carriage from source (to be identified by engineer in charge) to site of work /dumping place (To be identified by engineer in charge)including cost for loading and unloading.for an av. distance by mechanical transport 25 Km and H/L 50 m |
| 263 | Carriage of sand and stone aggregate below 40mm nominal size by Mechanical transport including loading, unloading and stacking |
| 264 | Carriage of sand by Mechanical transport including loading, unloading and stacking avg distance 80km & 300 mtr by Manual means |
| 265 | Carriage of stone aggregate below 40mm nominal size by Mechanical transport including loading, unloading and stacking avg distance 15km & 300 mtr by Manual means |
| 266 | Carriage of stone aggregate above 40mm nominal size upto a lead of 10km by MT including loading, unloading and stacking |
| 267 | Carriage of sand above 40mm nominal size upto a lead of 10km by MT including loading, unloading and stacking |
| 268 | Carriage of soiling stone upto a lead of 10km by Mechanical transport including loading, unloading and stacking |
| 269 | Carriage of soiling stone by Mechanical transport including loading, unloading and stacking |
| 270 | Carriage of material by Mechanical Transport stone soiling avg lead km |
| 271 | Cement, stone blocks, GI, CI, AC, Stainless steel and CC pipe below 100mm dia and other heavy materials |
| 272 | Cement, stone blocks, GI, CI, AC, Stainless steel and CC pipe below 100mm dia and other heavy materials |
| 273 | P/F of water bars |
| 274 | Operation and maintenance cost of scheme for 5 years (after completion of defect liability period) complete in all respects by operation and maintaining all the instructions during warranty period and maintenance period for 05 year with replamrement / repair all damage or non functioning units / components including accessories/ fittings etc. |
| 275 | 1st year |
| 276 | 2nd year |
| 277 | 3rd year |
| 278 | 4th year |
| 279 | 5th year Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail