| 1 | Surface dressing not exc 15 cm deep in soft & loose soil with grass around the manhole, soak well, drains and septic tank all as specified and directed |
| 2 | Excavation in trenches in soft/loose soil, n. exc. 1.5m wide and n. exc. 1.5m deep and getting out complete complete all as specified and directed |
| 3 | Returning filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed |
| 4 | Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete all as specified and directed |
| 5 | Cleaning of gully trap/Nahani trap/floor trap with cleaning tools and getting out sludge, mud, silt or other foreign materials complete all as specified and as directed . Note :- Obtained waste materials shall be disposed to a distance not less than 100 mtrs all as specified and as directed. |
| 6 | M&L for making good damaged surfaces of surroundings of nahani trap, Gully trap/floor traps etc with CM 1:3 or white cement complete all as specified and directed |
| 7 | Cleaning of septic tank / soak pits by removing man hole cover including removing of earth/soil spread over the cover if any, from the frame of a septic tank and receiving chambers, pumping out liquid contents and excavating night soil sediments and waste materials etc, clearing off up to the bottom floor and dispose off the materials excavated to contain night soil, place back the man hole cover to its original position. Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expenditure to the Government.Note:-The measurement shall be inclusive of water content from bottom of tank to the top level of water all as specified and directed |
| 8 | Opening manholes of septic tanks, removing night soil, other sediments, solid waste and liquid waste in any condition by septic tank cleaning vehicle , cleaning internal surfaces of the tank with clean water and refixing the manhole cover on completion of work complete all as specified and directed. Notes:-(a) The night soil, sediments, solid and liquid waste in any condition removed from septic tank shall be taken away from respective vicinities and premised in closed containers/conveyance and disposed off out of Defence land.(b) Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expenditure to the Government. |
| 9 | Cleaning Man holes by removing man hole cover, dewatering and getting out sludge, deposit mud, silt or other foreign materials and vegetation and cleaning the sides and floors of the man hole, removing over flowed sulage from surrounding of man holes and removing the same outside the defence land including taking of manholes covers and refixing the same in position and testing of manholes by filling with water complete all as specified and as directed. Manhole depth n exc 1.5 Mtr depth. |
| 10 | All as per item No 9 above here-in-before but for manhole depth exceeding 1.5m and not exceeding 3.00m complete all as specified and directed |
| 11 | Cleaning of SWG/PVC/CI pipe sewage line using mechanically compressor and removing foreign materials for 75mm dia pipe in vertical walls/floors complete all as specified and directed. |
| 12 | Cleaning of SWG/PVC/CI pipe sewage line using mechanically compressor and removing foreign material for 110mm dia pipe on vertical walls/floors complete all as specified and directed. |
| 13 | Cleaning of SWG/PVC/CI pipe sewage line using mechanically compressor and removing foreign material for 150mm dia pipe complete all as specified and directed. |
| 14 | Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above GL) all as specified and directed |
| 15 | M&L for precast reinforced concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab set in and pointed in CM 1:6 including necessary formwork complete all as specified and directed. |
| 16 | S&F TMT bars 10 mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 18 | M&L for cement concrete bed to drain pipe 150 mm dia in cement concrete 1:3:6 type C2 including packing under the haunching on sides all as directed and specified |
| 19 | M&L Reinforced concrete pipes 150mm, class NP2, laid and jointed complete with collars all as directed and specified |
| 20 | Demolition of brick work or stone masonry built in cement mortar including all quions, arches, pillars,etc but excluding ashlar facings, dressed stone work and precast concrete articles all as specified and directed |
| 21 | M & L precast cement concrete solid blocks exc 10 cm in width, built in cement mortar 1:6 type C1 1:3 :6 using 20 mm graded stone aggregate all as specified and as directed |
| 22 | M&L for rendering 15mm thick in CM 1:4 on on fair faces of brick work or concrete surface even and smooth using water proofing compound (WPC) & without using extra cement all as specified and as directed |
| 23 | M&L for Walling of polygonal rubble, uncoursed well bonded, bedded solidly hearted stone masonry built in cement morter1:6 complete all as specified and directed. |
| 24 | M & L for keyed pointing to random or polygonal rubble uncoursed or brought up to course in CM 1:4 complete all as specified and directed. |
| 25 | M & L for preparing newly plastered surfaces of wall and applying two coats of weather coat paint over a coat of primer all as specified and directed. |
| 26 | Demolition of cement concrete of any description and in any position ( un reinforced) all as specified and directed |
| 27 | M&L for PCC Coping in PCC 1:3:6 type C1 using 20mm graded aggregate including chamfered edges all as specified and directed |
| 28 | Supply only liquid water proofing compound all as specified and directed |
| 29 | S & F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed |
| 30 | S & F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed |
| 31 | S & F in repairs 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed |
| 32 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided for flooring hard sting etc complete all as directed. |
| 33 | M&L 75 mm thick PCC type D-2 ,1:4:8(using 40 mm graded stone aggregate) as in sub base of hard standing, flooring and paving etc complete all as specified and directed. |
| 34 | M&L 100 mm thick PCC type C-2 ,1::6(using 40 mm graded stone aggregate) as in sub base of hard standing, flooring and paving etc complete all as specified and directed. |
| 35 | M & L Chequered cement concrete tiles 25 mm thick, any shape and size, set & jointed in neat cement slurry in floors with grey cement and pigments over and incl. 20mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 36 | Demolition of Stone slabs /cement tiles etc of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar all as all as specified and directed |
| 37 | M&L for 200 mm thick as in Granular sub base of kantar or laterite, spread, rolled and consolidated to gradient and camber required etc complete all as specified and directed. |
| 38 | Sand filling under floors including watering and consolidation complete all as specified and directed |
| 39 | M & L Machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-30 Grade with pigments complete all specified and directed. |
| 40 | S & F in repair 20mm bore, 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings incl taking down the pipe complete all as specified and directed |
| 41 | S & F in repair 25 mm bore, 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings incl taking down the pipe complete all as specified and directed |
| 42 | Cleaning of water tank capacity 500 ltrs and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc complete all as specified and directed.Note :- Rate inclusive of dewatering of tank, removal of sludge, high pressure cleaning , vaccum cleaning & apply anti bacterial agents/ Ultra voilet redations. |
| 43 | Cleaning of water tank capacity 1000 ltrs and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc complete all as specified and directed.Note :- Rate inclusive of dewatering of tank, removal of sludge, high pressure cleaning , vaccum cleaning & apply anti bacterial agents/ Ultra voilet redations. |
| 44 | S & F in repair 25 mm bore,ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed .(Minimum weight 15mm-142 gms/20mm -210 gms/25mm -455 gms/40 mm-690 gms) all as specified and directed |
| 45 | S & F in repair chromioum plated fancy type 15 mm dia Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe/ ppr pipes or brass ferrule complete all as specified and directed |
| 46 | S & F in repairs fancy type Pillar taps 15mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron /PPR pipes and fixed complete all as specified and directed |
| 47 | S & F in repair fancy type 15 mm dia concealed type Stop valves,chromium plated with long shank and cup screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed |
| 48 | S&F in repairs EWC seat cover of any pattern including cover and Mild steel chromium plated hinging devices of any colour all as specified and directed. |
| 49 | S&F in repairs health faucet, CP with flexible pipe of bore 15mm with necessary holder , screws and fasterens fitted to wall complete all as specified and directed. |
| 50 | Supply & fixed (in repair) vitreous china wash down water closet pedestal pattern (EWC) , White including connection to trap and to flushing pipe with ‘P’ or ‘S’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hinges and Health Faucet with pipe complete all as specified and directed |
| 51 | S&F in repairs vitreous china squatting pan Orissa pattern size 580x440mm white integral foot rest, including concrete bedding with trap 100mm complete all as specified and directed |
| 52 | S & F for 500 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old tank of any capacity complete all as specified and directed |
| 53 | S & F for 1000 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old tank of any capacity complete all as specified and directed |
| 54 | S& F in repair tank cover suitable for any type fof Rotational moulded polyethylene water storage tanks specified and directed |
| 55 | S&F in repair 32 mm dia PVC waste pipe 90 cm long flexible type for Wash basin complete all as specified and directed |
| 56 | S&F 15mm bore PVC connection pipe, 450mm long fixed as in repairs specified and directed |
| 57 | S&F in repair 75 PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed. |
| 58 | S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity low level, white/coloured with inlet ball valve float and handle including bracket (incl. taking down old cistern ) and fixing of PVC flush pipe 32 mm dia and PVC connection pipes complete all as specified and directed. Please Enable Macros to View BoQ information |