| 1 | Dismantling / taking down AC waste/vent pipes fixed to walls with all fittings/ accessories 100 mm dia pipes. |
| 2 | Demolition & breaking up drain pipe (salt glazed , AC or reinforced concrete) set in cement mortar for 150 mm dia pipes. |
| 3 | All as per item No.2 above but for internal dia of pipe 200mm. |
| 4 | All as per item No. 2 above but for internal dia of pipe 300mm. |
| 5 | Demolition of brick work built in cement mortar including all arches, pillars all quoins etc complete all as directed. |
| 6 | M & L for excavation in trenches n exc 1.5M deep & exc. 1.5M wide and getting out in soft/loose soil |
| 7 | Demolition of cement concrete (reinforced) as in manholes cover. |
| 8 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redious built in CM 1:4 |
| 9 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface incl mixing of water proofing compound finished even & smooth with using extra cement. (Note: WPC shall be measured & paid seperately) |
| 10 | M&L for rendering 15mm thick in CM 1:6 other than fair faces of brick work finished even & smooth using extra cement complete all as directed. |
| 11 | Supply only integral water proofing compound. |
| 12 | S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm. |
| 13 | S&F.110 mm dia PVC (SWR) bends, any radius with access door |
| 14 | S&F 110 mm dia PVC (SWR) branch piece (Single Y) equal or unequal. |
| 15 | S&F 110 mm dia PVC (SWR) branch piece double, (Single Y) equal or unequal. |
| 16 | S&F 110 mm dia PVC (SWR) vent cowl |
| 17 | M&L for reinforced cement concrete pipes class NP-2 , laid in trenches & jointed complete with collars, dia of pipe 150 mm . |
| 18 | All as per item No. 17 above but for 200 mm internal dia of pipe. |
| 19 | All as per item No. 17 above but for 300 mm internal dia of pipe. |
| 20 | M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in bed to drain pipes, incl packing under & hauching against the sides of pipes after they are laid and tested for 150 mm bore RCC pipe. |
| 21 | All as per item No. 20 above but for 200 mm dia RCC pipe. |
| 22 | All as per item No. 20 above but for 300 mm dia RCC pipe. |
| 23 | M&L for cutting into existing manholes for connecting new drains making good to pipe & rendering, cutting. Out existing benching for & forming branch channel in cement concrete 1:2:4 type B-1 smooth finishing & reforming benchine as required for bore of pipe 150 mm. |
| 24 | All as per item No. 26 above but for bore of pipe 200 mm . |
| 25 | All as per item No. 26 above but for bore of pipe 300 mm . |
| 26 | M&L for 75 mm thick precast Cement concrete cover slabs 1:2:4 Type B-1 set and jointed in CM 1:6Note:- Reinforcement shall be measured and paid separately. |
| 27 | M&L for mild steel deformed bars 6 to 8mm dia cut to length, bent to shape required incl cranking, bending, hooking ends & binding with & incl mild steel wire (annealed) not less than 0.9 mm dia using for manhole cover/ slabs etc. |
| 28 | S & F in repair for CI nahani trap/floor trap incl jointing to waste pipe fixed in cement concrete 1:2:4 (Type B-2), 75mm diameter with gratings incl taking down old broken traps. |
| 29 | M&L for PCC type B-1, (1:2:4, using 20mm graded stone aggregate) as in sunken floor incl water proofing liquid @ 200ml per 50Kg cement. (water proofing liquid to be measured separately) finished even and smooth. |
| 30 | M&L for integral water proofing liquid @ 0.30 ltr per Sqm using water proofing compound for plaster & concrete using pidi proof for LW for sunken portion of toilets in plastering vertical surfaces & concreting at the bottom of sunken floor. Make: Dr Fixit, Pidilite. |
| 31 | M & L for polymer modified bituminous elastomanic water proof coating @ 0.60 Kg per Sqm in two layers for sunken portion of toilet Make: Dr Fixit, Pidilite |
| 32 | M&L rendering 15 mm thick in cm 1:4 in sunken portion on Brick / stone masonery surfaces, incl water proofing liquid @ 200ml per 50Kg cement. ((water proofing liquid to be measured separately) including finished even and smooth. |
| 33 | M&L for PCC type C-2, (1:3:6, using 40mm graded stone aggregate) in plinth protection or any other work etc.complete all as specified and as directed by Engr-in-charge. |
| 34 | S/F 40 mm dia PVC pipe (out from sunken portion) for spout. |
| 35 | S&F vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistem & fush pipe fixed in repairs incl \\"P\\" or \\"S\\" trap. |
| 36 | S&F in repairs Vitreous China wash down water closet pan with seat cover (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete. |
| 37 | Supply and fix hume pipe septic tank 50 users capacity including all excavation earth work required and demolition and removal of old septic tank (any size) and removal of debris,including vent pipe,cowl,rcc covers,plasters and connecting the new septic tank to the incoming sewer lines and connected to soak pit as directed. |
| 38 | All as per item No.37 above but 25 users |
| 39 | Dismantling floor hearth or wall tiling incl cement mortar bedding but not backing, complete al as specified. |
| 40 | M&L for Non-skid coloured Ceramic tiles of size 300 x 300 x 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over and including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified. |
| 41 | M&L for Glazed ceramic tiles 350mm x 250mm x 7mm or 450mmX300mmX7mm thick (square/rectangular) of approved colour on vertical surface, set and jointed in neat cement slurry and pointed with coloured cement to match the tile colour over 10mm thick rendering in CM (1:4) for wall. |
| 42 | M&L for vitrified coloured tiles 8 to 10 mm th (square/rectangular) polished area of each tile 0.30 sqm but n exc 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm th screed bed in CM 1:6 complete all as specified and directed. |
| 43 | All as per item No 42 above but on skirting over 8 to 10 mm th rendering in CM 1:4 complete all as specified and directed. |
| 44 | Returning filling in including levelling , watering and well ramming in layers n exc 25 cm thick in soil. |
| 45 | Removal of surplus soil to a distance n exc. 50 M & depositing where directed at a level n exc. 1.5 M above starting point. |
| 46 | Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified. |
| 47 | M & L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in sub base for hard standing etc.complete all as specified and directed. |
| 48 | M&L 40 mm thick P.C.C 1:2:4 type B-1 using 20 mm graded aggregate in surface finish |
| 49 | M & L PCC type D2 1:4:8 (40 mm Gr. Agg ) 75mm thick as in sub base complete all as specified. |
| 50 | M&L for laying machine pressed precast concrete interlocking reflective coloured (glossy finish)pavers block any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade over 30mm thick sand layer watering and ramming all as specified. |
| 51 | M& L Chequared Cement Concrete rubber moulded(glossy finish) Tiles 30 CM x 30 CM X 25 mm th set and jointed in cement slurry and pointed in neat grey cement & pigment in floors over screed bed 15 mm thk in cm 1:6 .complete all as specified. |
| 52 | M&L for cement conceret 1:3:6 Type C-2 Using 40 mm graded stone aggregate as in surface channel and drain bed. |
| 53 | Extra for forming fair finished drain or channel 30 cm inner girth or above in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. |
| 54 | Dismantling Plain or corrugated steel (corrugated/ semi corrugated etc) sheet in roof covering complete all as specified and directed. |
| 55 | S & F 0.5mm thick corrugated pre painted / coloured galvalume sheet in roofing fixing all as per manufactures instructions with all fittings and accessories etc complete. |
| 56 | All as per item No.55 above above but plain sheet fix in valley gutter / ridge/ view cutter |
| 57 | Dismantling wrought iron or mild steel work of any description not otherwise provided for . |
| 58 | S&F Rolled Sections or angle sections as in main croos beams , hip and jack rafters; purlins, where connected to common rafter , posts etc. conf to Fe-410-w(gdeE-250 quality-A) etc. complete all as specified and directed. |
| 59 | M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer. |
| 60 | S & F Vitreous china squatting plate urinal, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed. |
| 61 | S&F as in repairs PVC low/high level flushing cistern white 10 ltrs capacity incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl bracats fixed in repairs all as directed. Note Removing existing fluhing system of CI or any other quality incl brackets all as specified and as directed. |
| 62 | S/F Vitreous china wash basin white flat back size 580 x 450mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand alongwith 32mm dia CP waste coupling and PVC waste pipe in repairs complete all as directed. |
| 63 | S&F in repair pillar taps fancy type cast copper alloy, half threaded with heads, chromium plated, screwed down high pressure , with or without lettered HOT or Cold with long screwed shanks and fly nuts , srewed for iron pipe and fixed 15 mm dia of pipe all as specified. |
| 64 | Supply and fixing for vitreous china european dual type one piece type water closet with flushing cistern of size 780x375x700 mm star white over and including fittings such as s' trap distance pieces 100 mm long etc comple make : Hindware cat part No 92071 or equivalent all as specified and approved Accepting officer. |
| 65 | M&L for PCC type B1(1:2:4, using 20mm graded stone aggregate) as in bed blocks/coping/ edging all as specified and directed. |
| 66 | S & F for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter concrete work complete all as specified and as directed by engr-in-charge. |
| 67 | M & L for Type B1, (20mm stone aggregate) reinforcement cement concrete in Foundations, including rafts,footings, foundation beams;columns, etc.; basement slabs, under-reamed piles and mass concrete etc. as specified and directed by Engr-in-Charge. |
| 68 | M & L for TMT Bar 10 mm dia and over cut to length bent to shape required including cranking , bending binding spirally for hooping for colomns, footings, plinth beams hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, TMT Bar etc. complete all as specified and as directed by engr-in-charge. Please Enable Macros to View BoQ information |
| 69 | M & L for TMT Bar 10 mm dia and over cut to length bent to shape required including cranking , bending binding spirally for hooping for colomns, footings, plinth beams hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, TMT Bar etc. complete all as specified and as directed by engr-in-charge. Please Enable Macros to View BoQ information |