| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Repair/ replacement of unserviciable wiring at Mil Stn Beas and Jandiala Guru under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge |
| 3 | M & L in repair for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor (FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC casing caping with all accessories including 1.5 sqmm copper multistrand conductor (FRLS) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed.Note :- Sunken box , hylam plate will be measured and paid separately |
| 4 | One light point controlled by one, one way switch |
| 5 | One fan point controlled by one, one way switch |
| 6 | One socket outlet 3 Pin, 5 Amp on independent board |
| 7 | One socket outlet 3 Pin, 5 Amp on same board. |
| 8 | One bell point controlled by one bell push |
| 9 | One light point controlled by two, two way switch |
| 10 | All as per item No 2 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 11 | All as per item No 2 here in before but 4.0 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 3 pin 15 Amp switch socket combination on independent board. |
| 12 | M & L in repair for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor ( FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor (FRLS ) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed.Note :- Sunken box , hylam plate will be measured and paid separately |
| 13 | One light point controlled by one, one way switch |
| 14 | One fan point controlled by one, one way switch |
| 15 | One socket outlet 3 Pin, 5 Amp on independent board |
| 16 | One socket outlet 3 Pin, 5 Amp on same board. |
| 17 | One bell point controlled by one bell push |
| 18 | One light point controlled by one, two way switch |
| 19 | All as per item No 5 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board |
| 20 | All as per item No 5 here in before but 4.0 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 21 | Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FRLS) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with white frame for Modular fittings of required size for 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :- |
| 22 | One light point controlled by one, one way switch |
| 23 | One fan point controlled by one, one way switch |
| 24 | One socket outlet 3 Pin, 5 Amp on independent board |
| 25 | One socket outlet 3 Pin, 5 Amp on same board. |
| 26 | One bell point controlled by one bell push |
| 27 | One light point controlled by one, two way switch |
| 28 | All as per item No 8 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board |
| 29 | S&F in repair switch piano flush type single pole one way 6 Amp (ISI Marked) |
| 30 | S&F in repair switch piano flush type single pole two way 6 Amp (ISI Marked) |
| 31 | S&F in repair switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 32 | S & F in repair Bell push flush type 5 amp |
| 33 | S&F in repair socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) |
| 34 | S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 35 | S&F switch Modular piano flush type single pole one way 5- 10 Amp (ISI Marked) |
| 36 | S&F Modular switch piano type single pole one way 15 Amp (ISI Marked) |
| 37 | S&F Modular socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 38 | S&F Modular socket out let 2 in 1, 3 pin 5/6 Amp flush type (ISI Marked ) |
| 39 | S&F in repair Modular bell push switch one module . |
| 40 | S&F in repair Modular switch 2 way 6A, 250 V AC 1 module. |
| 41 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked) |
| 42 | Taking down old unsv sub main and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper conductor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6.00 Sqmm cable one run of 6.00 Sqmm cable as earth continuity conductor and one run of PVC Conduit shall be measured & paid as one unit.) |
| 43 | Taking down old unsv sub main and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper conductor, multi stranded cable of size 10.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 10.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Two run of 10.00 Sqmm cable one run of 10.00 Sqmm cable as earth continuity conductor and one run of PVC Conduit shall be measured & paid as one unit.) |
| 44 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. |
| 45 | Taking down old US MCB DB and S & F in Repair sheet metal enclosure for MCB DB double door single pole & Neutral 4 way with 200 Amps rated bus bar. |
| 46 | Taking down old US MCB DB and S & F in Repair sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 Amps rated bus bar. |
| 47 | Taking down old US MCB DB and S & F in Repair sheet metal enclosure for MCB DB double door Triple pole & Neutral 4 way with 200 Amps rated bus bar. |
| 48 | Taking down carefully ceiling fan of any size any description from existing location and carrying out cleaning & servicing including replacement unsv parts, painting with synthetic enamel paint by spraying, greasing and heat varnishing and refixing the same in same location/new location and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed .For the purpose of maintenance, each ceiling fan shall be treated as an assembly of the following serviceable components ( Item number 29 to 31) :-The unserviceable parts shall be measured and paid as separately. |
| 49 | Rewinding of ceiling fan size any description with same size wire and insulating material including replacement of suitable capacitor, ball bearing and other necessary reqd accessory for smooth functioning of fan complete all as directed by engineer in charge |
| 50 | S&F in replacement motor as single motor unit assembly consisting of single phase induction motor ( Including stator, rotor, shaft, bearings, and motor housing ) suitable for 50 - 125 watt Ceiling fan all as per sample kept in AGE E/M office . |
| 51 | S&F in replacement blade assembly (Including blades 3 nos , blade arms/brackets and fastening hardware)as per the suitability of a ceiling fan. all as per sample kept in AGE E/M office |
| 52 | S&F of electrical assembly (Including capacitor, internal wiring, terminal connectors, and associated electrical accessories such as regulator, if within scope) as per the suitability of ceiling fan all as per sample kept in AGE E/M office |
| 53 | Supply and Fix Suspension & Mounting Assembly (Including down rod, shackle/hook, canopy, and supporting fixtures) suitable for ceiling fan. All as directed by Engineer in Charge. |
| 54 | Taking down carefully exhaust fan of any size from existing location and carrying out cleaning & servicing including painting with synthetic enamel paint by spraying, greasing and heat varnishing and refixing the same in same location/new location and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed .For the purpose of maintenance, each Exhaust fan shall be treated as an assembly of the following serviceable components ( Item number 34 to 38) :-The unserviceable parts shall be measured and paid as separately. |
| 55 | Rewinding of exhaust fan any size any description with same size wire and insulating material including replacement of suitable capacitor, ball bearing and other necessary reqd accessory for smooth functioning of fan complete all as directed by engineer in charge |
| 56 | S&F in repair motor unit assembly (Including stator, rotor, shaft, bearings, and motor housing of desired capacity and material. all as per sample kept in AGE E/M office |
| 57 | S&F in repair impeller/blade assembly (Including fan blades/propeller, hub, and fastening hardware). All as per the directions of Engr-in Charge |
| 58 | S&F in repair casing & mounting assembly (Including outer frame, mounting brackets, louvers/shutters, and fixing arrangements). all as per sample kept in AGE E/M office |
| 59 | S&F in repair electrical assembly (Including capacitor, internal wiring, terminal connectors, and associated electrical accessories such as regulator/switch, if within scope. all as per sample kept in AGE E/M office |
| 60 | Taking down carefully Geysers of capacity 25 Ltr from existing location and carrying out cleaning of inner tank with descaling compound repairing including changing of u/s components(excluding heating element thermostat), including painting with synthetic enamel paint by spraying, and re fixing the same in same location/new location. |
| 61 | S&F in repair geyser inner tank assembly including inner assembly , indicator, safety valve, multifunction valve, thermal switch, auto cut switch, gaskets, gasket, fasteners complete suitable for 25 litter including connecting electrical lead all as per sample kept in AGE E/M office |
| 62 | S&F in repair geyser outer body made out of metal/Abs , insulating material suitable for 25 litter capacity all as per sample kept in AGE E/M office |
| 63 | S&F in repair PVC flexible connecting pipe for cold/hot water 450mm ling with brass end plug as specified and directed. |
| 64 | S&F in repair Heating element 2000Watt with triangular/round base mounting suitable for 25 Ltr capacity as specified and directed.. |
| 65 | S&F in repair Thermostat suitable for Geyser of Capacity 25 Ltr as specified and directed. |
| 66 | S&F in repair Fan capacitor 2.5 MFD. |
| 67 | S&F in repair Fan capacitor 4 MFD. |
| 68 | S&F in repair Sleek round recessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination Sleek Surface 6Watt , Colour Temp 3000 K 5000 K all as directed |
| 69 | S&F in repair Sleek square recessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination Sleek Surface 6Watt , Colour Temp 3000 K 5000 K all as directed |
| 70 | S&F in repair Sleek round recessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination Sleek Surface 12Watt, Colour Temp 3000 K 5000 K all as directed |
| 71 | S&F in repair sleek square recessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination 12 watt, Colour Temp 3000 K 5000 K all as directed |
| 72 | S&F in repair LED batten tube light (4ft) for surface and pendant applications.18/ 20 watt, Colour Temp 3000 K 5000 K all as directed |
| 73 | S&F in repair LED strip Non-integral flexible LED strip light with high brightness for indoorapplications. 25 watt x 5 meter length, Colour Temp 3000 K 5000 K all as directed |
| 74 | S&F in repair Driver for LED strip 25 Watt |
| 75 | S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Colour Temp 3000 K 5000 K all as directed |
| 76 | S&F in repair LED Security light fitting 35 watt Pressure die cast aluminium housing, heat resistant toughened glass with frame IP 66 Protection j complete fitting all as specified and directed by Engineer-in-Charge. Colour Temp 3000 K 5000 K all as directed |
| 77 | S&F in repair PVC insulated aluminium 6 Sqmm 2 core sheathed cable |
| 78 | S&F in repair Miniature Circuit Breaker (MCB) ‘B’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads Single pole 6 to 32 Amp |
| 79 | S&F in repair Miniature Circuit Breaker (MCB) ‘B’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads Single pole & neutral 6 to 32 Amp |
| 80 | S&F in repair Miniature Circuit Breaker (MCB) ‘B’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads Triple pole & neutral 6 to 32 Amp |
| 81 | S&F in repair Miniature Circuit Breaker (MCB) ‘B’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads Triple pole & neutral 40 Amp |
| 82 | S&F in repair TP&N Vertical DB 4 way ,MCCB as Incomer with Bus Bars, Neutral Links, Blanking Plates complete |
| 83 | S&F in repair MCCB 100 Amp , 415 volt 4 pole complete |
| 84 | S&F in repair Modular switch 6 Amp 250 V AC one way one module as per suitability of Frame already existing on work site. |
| 85 | S&F in repair Modular switch 16 Amp 250 V AC one way with indicator one module as per frame suitability already existing on work site. |
| 86 | S&F in repair Modular Socket, 6A - 2/3 pin combined 2 module as per frame suitability already existing on work site. |
| 87 | S&F in repair Modular Socket 6A/16A - 2/3 pin combined 2 module on work site. |
| 88 | S&F in repair modular Fan regulator step type, 100 - 2 module on work site. |
| 89 | S&F in repair Metal flush mounting box of 1/2 Module complete all as specified and as directed. |
| 90 | S&F in repair Metal flush mounting box of 3 Module complete all as specified and as directed. |
| 91 | S&F in repair Metal flush mounting box of 4 Module complete all as specified and as directed |
| 92 | S&F in repair Metal flush mounting box of 6 Module complete all as specified and as directed. |
| 93 | S&F in repair Metal flush mounting box of 8 Module complete all as specified and as directed. |
| 94 | S&F in repair White cover plate with frame, 1 module complete all as specified and as directed. |
| 95 | S&F in repair White cover plate with frame, 2 module complete all as specified and as directed. |
| 96 | S&F in repair White cover plate with frame, 3 module complete all as specified and as directed |
| 97 | S&F in repair White cover plate with frame, 4 module complete all as specified and as directed. |
| 98 | S&F in repair White cover plate with frame, 6 module complete all as specified and as directed. |
| 99 | S&F in repair White cover plate with frame, 8 module complete all as specified and as directed. |
| 100 | S&F in repair electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan |
| 101 | S&F in repair Buzzer/Ding Dong, A C , 230 volt single pole |
| 102 | S&F in repair PVC/Polycarbonate Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings type with back plate suitable for batten fittings complete all as specified and as directed. |
| 103 | S&F in repair PVC gang box for mounting switches 01 module, |
| 104 | S&F in repair PVC gang box for mounting switches 02 module, |
| 105 | S&F in repair PVC gang box for mounting switches 06 module, |
| 106 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. Size |
| 107 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 2 way |
| 108 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 4 way |
| 109 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 6 way |
| 110 | S&F in repair LED Bulk head fitting 10 watt highly cost effective compact, ultra low energy, modern design utility bulkhead suitable for indoor and outdoor applications with IP 65 protection complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-Charge. |
| 111 | M&L for repairing of unserviceable wiring of distribution board any type any capacity including adding new wire of same size same material, insulating properly bare joint, systematically arranging wiring using clamps , conduits , etc all as reqd , all as directed. |
| 112 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 4 core laid in trenches, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 113 | S&F in repair decorative garden light 10 W suitable for withstanding outdoor weather and rain,dust tight, IP-65 all as per directions of Engineer in Charge |
| 114 | S&F in repair 12W Emergency Inverter LED Bulb, Cool Day Light (6500K), Rechargeable Bulb with 3 Hours Backup, Ideal for Powercuts, Energy Efficient, B22 Base all as per the direction of E/M |
| 115 | S&F in repair 30CM Rechargeable Motion Sensor LED Light for Wardrobe, Closet, Cabinet, Kitchen, Under Stairs, Drawer, Shelf, Garage, Tool Shed - 3 Color Modes, Stepless Dimming, Magnetic Closet Light |
| 116 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 10 Sqmm 2 core laid in trenches, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 117 | S&F in repair LED batten tube light (2ft) for surface and pendant applications. 8-10 watt |
| 118 | S&F in repair MCB protected socket PVC plastic base model suitable for geyser and Acs complete unit comprising mcb and socket box of reputed make , 25 Amp, 240 volt, 50 Hz |
| 119 | S&F in repair plastic body exhaust fan 200 dia , rust proof body, dust protection shutter connecting lead suitable for toilet/bathroom Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |