| 1 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons, riser of steps, skirting, dado etc laid in any mortar complete all as specified. |
| 2 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed |
| 3 | M & L for providing 75 mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors/Path complete all as specified and directed |
| 4 | M & L PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) 25mm thick as in levelling course, sub-floors and paving etc complete all as specified. |
| 5 | M&L chequered Cement concrete tiles 30 cmx30cmx 25 mm thick set, jointed and pointed neat cement slurry in floor with grey cement and pigments , incl CM (1: 4) 20 mm thick screed bed all as specified and directed by Engr-in-Charge. |
| 6 | M&L for 16-18mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms etc laid bedded over 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite including Rounding, grinding and mirror polishing complete all as specified.(Note : Colour of granite shall be as approved by Engr-In-Charge) |
| 7 | Dismantling floor, hearth or wall tiling including CM bedding, removing rubbish off the premises complete all as specified and as directed. |
| 8 | M & L for heavy duty designer Vitrified tiles of size 300 X 300 X 10.8mm thick, or high dimension (except thickness) of any colour any design Durastone, weather proof impact resistant, abrasion resistant exterior tiles, as in floors etc , set and jointed in neat cement slurry over and pointed in white or coloured cement to match, over 15mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 9 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 10 | M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) all as specified. |
| 11 | M&L for preparation of new plastered surfaces of walls/concrete, kerb stone etc of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 12 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and directed |
| 13 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed |
| 14 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, fixed with self tapping screws all as specified and directed |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed |
| 16 | S&F mild steel roof trusses (framed), trrussed, purlins, crane gantries, rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E-250) quality-A all as specified and directed |
| 17 | M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 18 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed |
| 19 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 all as specified |
| 20 | Material and Labour for PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) as in surface channels and drains etc complete all as specified and as directed. |
| 21 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping including necessary form work complete all as specified |
| 22 | Demolition of cement concrete (reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed |
| 23 | M&L for providing precast reinforced cement concrete cover slabs for drain in RCC (1:2:4) B-1, using 20mm graded aggregatecomplete all as specified and as directed. |
| 24 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia for securing with clips quality conforming to deformed or twisted bars complete all as specified and directed |
| 25 | Excavation in post hole in hard/dense soil (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface complete all as specified and directed |
| 26 | M&L for cement concrete 1:3:6 type C2 (Using 40mm graded stone agrregate) as in foundation of posts, railing and similar work complete all as specified and directed |
| 27 | M&L for mild steel work as posts and struts in fencing including cutting tops as required drilling holes, notching for wires etc and similar works conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 28 | S&F mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-410W, Gde-E-250 Quality-A) complete all as specified and directed |
| 29 | S&F mild steel screw bolt (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank 11 to 15 mm and length of bolt exc 5 cm but n. exc 10 cm complete all as specified and as directed |
| 30 | S&F mild steel round bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns, hooking ends and binding with MS post of grade Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified and directed |
| 31 | Supply and fix mild steel galvanised PVC coated chain link fencing 3.15mm nominal dia of GI wire, 1.4mm thick PVC coating and average area of aperture 25 sqcm with weight of chain link not less than 3.60 Kg/Sqm complete all as specified and directed |
| 32 | S&F for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc of required size on the top of floor or the side of waist slab with suitable arrangement complete all as specified |
| 33 | M&L for precast cement concrete solid building blocks or slabs Type B1 1:2:4 (20 mm graded aggregate) 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls complete all as specified and as directed. |
| 34 | Supply & fix Cable Junction Box of size 130 x 130 x 77, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry of size 2.5 sqmm to 6 sqmm twin core with earth ,Lighting Outgoing cable: 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, including terminals, Material: PC-GFS (polycarbonate) , Weatherproof, resistant to weather influences including taking down the old/unserviceable junction boxes all as specified and directed. Make : Hensel model No DK 0606 G or equivalent to Sintex |
| 35 | Supply and fixing on piller, wall etc outdoor type Decorative Post top for 360° indirect light with IP 65 protection, resistant to impact and corrosion of 240 v,50hz of capacity 40 watt LED suitable for mounting on GI pipe including taking down the old/unserviceable light fittings all as specified and directed by Engr in charge. Make:Cat Part No : LPTO-40-CDL-M of CG or equivalent to Phillips/Havells |
| 36 | M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 sq mm single core 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl rigid PVC concealed/surface conduit (ISI marked) incl all specials/ accessories etc and provision of PVC insulated FRLSH copper conductor single core cable of same size but green in colour as continuous earthing wire all as directed. |
| 37 | All as above item No 36 above, but , 2 single core 1.5 sq mm complete all as specified and asd directed.NOTE for item No 36 & 37: Two runs (1P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. |
| 38 | M & L Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement all as specified and as directed by Engineer-in- Charge |
| 39 | Taking down of old rusted / damaged pipe line and Supply and fixing pipe galvanized, “Medium class”, including fittings 50 mm dia all as specified and directed. |
| 40 | Supply, laying, testing and commissioning of underground LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 x 16 sqmm (laid in trenches,ducts,pole,wall etc.) incl taking down old unsv cable all as specified and directed. |
| 41 | Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm (OD) x 32 mm (ID) along with connected accessories like couplers, bends,end caps etc. for LT cable protection all as specified and directed. |
| 42 | Excavation in trenches not exc 1.5 M deep and 1.5 M width and getting out in soft or loose soil for foundation of poles (or) cable laying complete all as specified and as directed. |
| 43 | Returning, filling incl spreading, levelling, watering and well ramming layers not exc 25 M for cable laying complete all as specified and as directed. |
| 44 | Removing/excavated soil to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point all as specified and directed. Please Enable Macros to View BoQ information |