| 1 | Taking down from any height carefully concealed/ casing caping/ ERW pipe point wiring copper / aluminium (light / fan / scoket) complete/as required (with fittings such as switches ceiling rose, pendents, regulators sockets etc as required) and making good disturbed surface with exisitng specification all as specified and directed by Engr-in-Charge. |
| 2 | Point wiring for explosive sheds and other required bldgs with 1100 Volts grade PVC insulated single core FRLSH cable with strranded copper conductor of size 1.5 Sqmm drawn through and including ERW rigid stove enamelled steel conduit of suitable size but not point less than 19mm dia with and includings all accessories, bends,elbow,coupling etc and incl 1.5 Sqmm earth FRLSH copper wire etc complete all as specified. |
| 3 | Point wiring for explosive sheds and other required bldgs with 1100 Volts grade PVC insulated single core FRLSH cable with stranded copper conductor of size 2.5 Sqmm drawn through and including ERW rigid stove enamelled steel conduit of suitable size but not point less than 19mm dia with and includings all accessories, bends,elbow,coupling etc(and incl 2.5 Sqmm earth FRLSH copper wire etc complete all as specified. |
| 4 | Point wiring for explosive sheds and other required bldgs with 1100 Volts grade PVC insulated single core FRLS cable with stranded copper conductor of size 4 Sqmm drawn through and including ERW rigid stove enamelled steel conduit of suitable size but not point less than 19mm dia with and includings all accessories, bends,elbow,coupling etc and incl 4sqmm earth FRLSH copper wire etc complete all as specified. |
| 5 | Supply and fix in replacement LED tube light fitting. 1 x 16W / 20W flameproof type FLP-WP made of aluminium alloy LM6 complete with all accessories suitable for Gas/Vapour Group of IIA & IIB and Zone 1 & IP-65 Protection. Make:n Havells/Bajaj/Sudhir |
| 6 | Supply and fix in replacement LED tube light fitting. 2 x 16W / 20W flameproof type FLP-WP made of aluminium alloy LM6 complete with all accessories suitable for Gas/Vapour Group of IIA & IIB and Zone 1 & IP-65 Protection. ake:- Crompton Cat Part No EXTN2LT8-16/20 or equivalent in Havells/Shyaam/Sudhir |
| 7 | Supply and fix in replacement flame proof rotary switch, in cast aluminium LM-6 suitable for 16A, single pole 250V with protection IP-65, equipement standard as per IS-2148/81 complete as specified and directed by Engr-in-Charge. Make:- SUDHIR or Equivalent iin BALIGA/FLEXPRO.Note. The rate quoted to be inclusive of brackets made of MS steel of suitable size for the above fittings. |
| 8 | Supply and fix in replacement Switch flame proof rotary type with termination box in LM6, 16A, double pole 250V with protection IP-65, equipement standard as per IS-2148/81 complete as specified and directed by Engr-in-Charge. Make:- SUDHIR or Equivalent iin BALIGA/FLEXPRO. Note. The rate quoted to be inclusive of brackets made of MS steel of suitable size for the above fittings. |
| 9 | Supply and fix in replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth with protection IP-65, equipement standard as per IS-2148/81 complete all as specified and directed by Engr-in-Charge. Make:- SUDHIR or Equivalent iin BALIGA/FLEXPRO. Note. The rate quoted to be inclusive of brackets made of MS steel of suitable size for the above fittings. |
| 10 | M & L in replacement flame proof 3 way lighting junction box (100 mm dia) with plain cover in cast aluminium LM-6 material, with protection IP-65, equipement standard as per IS-2148/81 equipment standard , alongwith cable glands complete all as specified and directed.PLUTO/ SUDHIR / BALIGA/FLEXPRO/. Note. The rate quoted to be inclusive of brackets made of MS steel of suitable size for the above fittings. |
| 11 | M & L in replacement flame proof 4 way lighting junction box (100 mm dia) with plain cover in cast aluminium LM-6 material, with protection IP-65, equipement standard as per IS-2148/81 equipment standard , alongwith cable glands complete all as specified and directed. PLUTO/ SUDHIR / BALIGA/FLEXPRO. Note. The rate quoted to be inclusive of brackets made of MS steel of suitable size for the above fittings. |
| 12 | S & F in replacement Flame proof - weather proof LED flood light fitting with protection IP-65 suitable for 100Watt for outdoor type complete all as specified and directed. Make:Shyaam/ Crompton/Havells/Sudhir |
| 13 | S & F in replacement Flame proof - weather proof LED flood light fitting with protection IP-65 suitable for 60Watt for indoor type complete all as specified and directed. Make:Shyaam/ Crompton/Havells/Sudhir |
| 14 | M&L point wiring complete with 1.5sqmm single core unsheathed PVC insulated FRLSH cable 1100 V grade multistranded copper conductor of different code of ISI marked drawn through and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including metal box and provision of Modular Box,cover plate of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and directed. (a) One light point controlled by one switch one way |
| 15 | (b) One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way |
| 16 | (c) One socket outlet three pin 5/6 Amps controlled by one switch on the same board. |
| 17 | (d) One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board. |
| 18 | M&L for point wiring with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and unsheathed cable 1100 volts grade, ISI marked drawn in and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly MS sunk terminal box including Modular Box,cover plate for mounting switches, socket and regulator complete all as specified and directed. |
| 19 | S&F modular socket outlet Multipurpose type but 5A/15A flush type complete all as specified and directed including taking down old U/S one . |
| 20 | S&F modular Switch flush type 15/16A complete all as specified and directed including taking down old U/S one . |
| 21 | M&L Modular switch one way, 6 Amps, 240 V complete all as specified and directed including taking down old U/S one. |
| 22 | S&F modular socket outlet 2/3 pin type,6 Amps, 240 V complete all as specified and directed including taking down old U/S one .Make : Anchor/Havells/cona |
| 23 | S&F in replacement sheet metal enclosure Single pole and neutral 240 V with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp complete all as specified and directed Make : Havells/legrand/Schneider |
| 24 | S&F ceiling rose surface type with 3 terminals complete including taking down old U/S one .Make : Havells/SSK/Cona |
| 25 | S&F fan regulator electronic step type AC 240 Volts,50 Hz complete including taking down old U/S one . |
| 26 | S&F in replacement lamp holder,PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed including taking down old U/S one. |
| 27 | S and F in replacement LED tube lights fitting. 1x18/20W all as specified and as directed. |
| 28 | Supply and Fix to wall / pole of any height LED bldg security light 35 watt IP 65 including GI pipe suitable size bracket not less than 1 metre bend to shape with 2 clamps, nuts, bolts, washers and PVC 3 core ISI mark flexible wire from ceiling rose to fitting complete including taking down u/s lights all as specified and as directed. |
| 29 | Taking down carefully sub main wiring including batten/ conduit/ERW stove enameled metallic rigid conduit by unscrewing from wall, ceiling and making good surfaces to match with original status as specified and directed. |
| 30 | Excavation in trenches not exc 1.5m wide and not exc 1.5M depth for laying of cables,GI/CI pipe lines etc getting out including forming bottom surface to required level and gradient in hard/dense soil.complete all as specified and directed. |
| 31 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil. complete all as specified and directed. |
| 32 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. |
| 33 | Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and directed. |
| 34 | Supply and fixing Double wall corrugated High Density POLYMER Ethylene (HDPE) pipe of size 50 mm as per IS 14930 (Part-2):2001, Laid in Trenches/floors and fixed on walls/poles, with and including necessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed HDPE Pipe size 50 mm. |
| 35 | Material and labour for Submain wiring with three single core with flame Retardant and low smoke (FRLSH), copper conductor three run 2.5 sqmm (Nominal area ) including earth conductor of same size using approved colour coding as IS (Red, Black and Green for single phase circuit), unsheathed stranded copper cable 1100 volts grade ISI marked with TEC and FIA approved and including drawing into surface mounted ERW stove enameled metallic rigid conduit of suitable size with necessary fixing accessories and fittings such as Tees, bends,elbow,juction boxes, connecters, saddles, screws, rowel plug etc all as specified and directed. Note:- (i) Three run of 2.5 sqmm and one run of ERW steel conduit shall be measured as one length.(ii) All coduit pipe and coduit accessories shall be totally enclosed IP-65 protection and certified by CMRI Dhanbad.(iii) The complete electrical installation/wiring and all equipment and apparatus shall be got tested and certified as totally enclosed as suitable for use in explosive building on completion by the \\" Director Central Mining Research Institute (CMRI) Dhanjbad. The testing charges complete and arranging tools, plants, testing equipments et shall be born by the contractor. |
| 36 | Material and labour for Submain wiring with three single core with flame Retardant and low smoke (FRLSH), copper conductor three run 4 sqmm (Nominal area ) including earth conductor of same size using approved colour coding as IS (Red, Black and Green for single phase circuit), unsheathed stranded copper cable 1100 volts grade ISI marked with TEC and FIA approved and including drawing into surface mounted ERW stove enameled metallic rigid conduit of suitable size with necessary fixing accessories and fittings such as Tees, bends,elbow,juction boxes, connecters, saddles, screws, rowel plug etc all as specified and directed. Note:- (i) Three run of 4 sqmm and one run of ERW steel conduit shall be measured as one length.(ii) All coduit pipe and coduit accessories shall be totally enclosed IP-65 protection and certified by CMRI Dhanbad.(iii) The complete electrical installation/wiring and all equipment and apparatus shall be got tested and certified as totally enclosed as suitable for use in explosive building on completion by the \\" Director Central Mining Research Institute (CMRI) Dhanjbad. The testing charges complete and arranging tools, plants, testing equipments et shall be born by the contractor. |
| 37 | M&L flame proof distribution board TPN 4 way ( Totally enclosed dust and flame proof /jet proof ( IP-65 protection) including flame proof MCB TPN 32-01 NOS, SP 5 to 30 Amps-12 NOS 240 volts AC 10KA (10 Nos) and RCCB 01 Nos 40 Amps, TPN MCB 40 Amps 415 volts AC 50 Hz 16 KA (01 No) Flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981 , with complete internal bus bar & wiring upto terminals. |
| 38 | M&L flame proof distribution board SPN 8 way ( Totally enclosed dust and flame proof /jet proof ( IP-65 protection) including flame proof MCB SPN 32 Amp-01 NOS, SP 5 to 30 Amps-6 NOS 240 volts AC 10KA, Flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981, with complete internal bus bar & wiring upto terminals. |
| 39 | S and F in repairs of sheet steel enclosure with double door flush mounting, MCB, DB, SPN, 4 ways, 240 volt factory fitted rated bus bars,earth bar,neutral links complete including. blanking plates as required and making good the disturbed surfaces. MAKE: Havells/Standard/Indoasian |
| 40 | S and F in repairs of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 8 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete including. blanking plates as required and making good the disturbed surfaces. MAKE: Havells/Standard/Indoasian |
| 41 | S and F in repairs of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 12 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete including. blanking plates as required and making good the disturbed surfaces. MAKE: Havells/Standard/Indoasian |
| 42 | S and F in repairs of sheet steel enclosure with Double door TPN 4 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete including blanking plates as required and making good the disturbed surfaces all as specified and as directed. MAKE: Havells/Standard/Indoasian |
| 43 | S and F in repairs of sheet steel enclosure with Double door TPN 8 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete including blanking plates as required and making good the disturbed surfaces. |
| 44 | S and F in repairs sheet metal enclosure single pole and neutral 240 V with a two pin and earth plug and socket complete with two pole MCB of 20 to 32 Amp complete all as specified and as directed. MAKE: Havells/Standard/Indoasian |
| 45 | S and F in replacement of MCB TPN 63 Amps 415V ,50 Hz ,breaking capacity 10 KA,\\" C \\" series all as directed. MAKE: Havells/Standard/Indoasian |
| 46 | S and F in replacement of MCB SPN 40 Amps 240V ,50 Hz, breaking capacity 10 KA,\\" C \\" series all as directed. MAKE: Havells/Standard/Indoasian |
| 47 | S and F in replacement of MCB SPN 20 to 32Amps 240V ,50 Hz, breaking capacity 10 KA,\\" C \\" series all as directed. MAKE: Havells/Standard/Indoasian |
| 48 | S&F MCB SP 6-32 Amps 240V ,50 Hz, breaking capacity 10 KA,\\" C \\" series all as directed. MAKE: Havells/Standard/Indoasian Please Enable Macros to View BoQ information |
| 49 | S&F MCB SP 6-32 Amps 240V ,50 Hz, breaking capacity 10 KA,\\" C \\" series all as directed. MAKE: Havells/Standard/Indoasian Please Enable Macros to View BoQ information |