| 1 | Construction of Fish Processing Unit at Trout Fish Farm patlikuhal Distt Kullu (H.P) (SH-: Providing Air Curtain,metal duct & E.I therein) |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.(a) Group-C as directed by engineer in charge |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make:-ANCHOR as directed by engineer in charge |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make:-ANCHOR as directed by engineer in charge |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire as directed by engineer in charge |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza2 X 4 sq. mm + 1 X 4 sq. mm earth wire as directed by engineer in charge |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza 4 X 6 sq. mm + 2 X 6 sq. mm earth wire as directed by engineer in charge |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza4 X 16 sq. mm + 2 X 6 sq. mm earth wire as directed by engineer in charge |
| 9 | Supplying and fixing batten/ angle holder including connection etc. as required. Make:-Anchor as directed by engineer in charge |
| 10 | Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-L&T as directed by engineer in charge |
| 11 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-L&T 63Amp as directed by engineer in charge |
| 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.L&T, 12 way, Double door as directed by engineer in charge |
| 13 | Providing and Fixing of IP20 LED fixture of 18 watt +/- 1 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. led downlighter in 18 W as directed by engineer in charge |
| 14 | Supplying and fixing street light with five year warranty LED 30 watt with G.I bracket die cast Aluminium housing with frame and toughened glass, pipe mounting 5700k, (Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make - Panasonic/Philips/wipro as directed by engineer in charge |
| 15 | Supply,Erection,Installation and commissioning of Uniearth maintenance free chemical earthing system consisting of environment friendly ground enhancing compound 'G.E.C' 50kg or as required at site having anticorrosive and hygroscopic properties to replace excavated soil. It should consist of Uniearth copper bonded electrodes, as per site conditions and soil resistivity at various depth levels and different terrains. The electrodes should have coating of 250 microns of molecularly bonded pure electrolytic copper(99.9%) in 2 meter length,17.2 mm diameter,terminal joint 200X25X6mm GI Strip with exothermic welds. The electrode should be duly tested and certified by CPRI for 30kA short time current test for 1 sec rms. as directed by engineer in charge |
| 16 | Providing & Fixing 6 SWG G.I wire on surface or in recess for loop earthing as required connections etc. as directed by engineer in charge |
| 17 | Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make:-,BAJAJ, Exhaust Fan, Heavy duty as directed by engineer in charge |
| 18 | Providing and fixing Water Proof Switch With Socket 3 Phase 32 amp rating RS PRO IP67 Red Wall Mount 3P+N+E Vertical Industrial Power Socket 32A 400V Legrand making connections, etc. as required. 32A 400v as directed by engineer in charge |
| 19 | Providing and fixing Water Proof Switch With Socket 3 Phase 16amp rating Legrand IP67 Red Wall Mount 3P+N+E Vertical Industrial Power Socket 16A 400V Legrand making connections, etc. as required. 16A 400V as directed by engineer in charge |
| 20 | Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The panel should be approved /Tested from the CPRI lab.& should confirmed to ISI: 64139 I) i) 300 mm Deep as directed by engineer in charge |
| 21 | Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required as directed by engineer in charge |
| 22 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.ANCHOR UNO,L&T,LEGRAND 32 A -100A 18 KA as directed by engineer in charge |
| 23 | Supplying and fixing of voltmeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 complete with connection ;testing and commissioning etc as required. Make L&T, Legrand, Hager, ABB or its equivalent as per best satisfaction of Engineer-in -charge. |
| 24 | Supplying and fixing of ammeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 complete with connection ;testing and commissioning etc Make L&T, Legrand,Hager, ABB as directed by engineer in charge |
| 25 | S/F indicator set RYB with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required as directed by engineer in charge |
| 26 | Supply, Installing, testing and commissioning SHARP AIR CURTAIN 2 FEET MS POWER COATED air cartains insect killer fly catcher gum bord auto hand dryers laminar air flow pass door interloking show & Uniform locker also deals in pharma equipment & pvc Strip PVC strip blinds etc. as required as directed by engineer in charge |
| 27 | Supply, Installing, testing and commissioningSHARP AIR CURTAIN 3 FEET MS POWER COATED air cartains insect killer fly catcher gum bord auto hand dryers laminar air flow pass door interloking show & Uniform locker also deals in pharma equipment & pvc Strip PVC strip blinds etc. as required as directed by engineer in charge |
| 28 | Supply, Installing, testing and commissioning SHARP AIR CURTAIN 4 FEET MS POWER COATED air cartains insect killer fly catcher gum bord auto hand dryers laminar air flow pass door interloking show & Uniform locker also deals in pharma equipment & pvc Strip PVC strip blinds etc. as required as directed by engineer in charge |
| 29 | Supply, installation and testing of factory fabricated 120 GSM sheet metal ducts including 12 inch section pipe of following thicknesses including Wire Rope Hangers & Supports complete with end fixing, flexible connections in ducting, nut bolts, gasket, splitter dampers and vanes etc. complete as per specification in accordance with the approved shop drawings and required by the specifications.The ducting shall be provided as per SMACNA standard. 24 gauge galvanised sheet with 12 inch suction pipe as directed by engineer in charge Please Enable Macros to View BoQ information |