| 1 | Part- A Materials (Provided by contractor) |
| 2 | ST Pole 9 mtr |
| 3 | ST Pole 11 mtr |
| 4 | PCC Pole 8.5 mtr |
| 5 | 11 KV X-arm |
| 6 | 11 KV X-arm clamp |
| 7 | 11 KV Polymer Pin Insulators |
| 8 | 11 KV Polymer Disc Insulator T&C Type |
| 9 | 11 KV Disc Fitting |
| 10 | ACSR Weasel conductor |
| 11 | LT AB Cable (3x120+1x95+1x16) mm2 |
| 12 | LT AB Cable (3x95+1x70+1x16) mm2 |
| 13 | LT AB Cable (3x50+1x35+1x16) mm2 |
| 14 | LT AB Cable (1x25+1x16) mm2 |
| 15 | PVC cable 1x16 sq.mm single core for DB Connection |
| 16 | 11 KV ‘F’ Bracket with Bolts and Nuts |
| 17 | Number Plate with clamps. |
| 18 | Danger Board with Clamps. |
| 19 | Barbed wire |
| 20 | Alluminium Paint |
| 21 | Red Oxide Paint |
| 22 | Bolts, Nuts & Washers |
| 23 | Earthing Complete (Earthing Rod with per 2 Kg GI Wire) |
| 24 | 11 KV Top Channel |
| 25 | MS Channel Dropper (For fuse set) 100x50x2028 mm |
| 26 | Clamp for top, dropper with nut and bolt |
| 27 | PG Clamp as suitable for Dog/ Weasel conductor |
| 28 | 11 KV Stay Set complete (01 set =01 No Stay Rod 16x1800 mm+01 No Stay clamp+05 Kg 7/10 SWG GI Wire) |
| 29 | Dead End Clamp for AB Cable |
| 30 | Three phase distribution box |
| 31 | Three phase distribution box clamps |
| 32 | Single phase distribution box |
| 33 | Single phase distribution box clamp |
| 34 | I clamp |
| 35 | I Hook |
| 36 | Suspension clamp |
| 37 | piercing connector |
| 38 | 11 KV T-off Channel 125x65x1300mm |
| 39 | T-off Channel holding clamp with Bolts and Nuts |
| 40 | MS Guarding Angle |
| 41 | GI Wire 6 SWG |
| 42 | GI Wire 8 SWG |
| 43 | Holding Clamp for Guarding Angle |
| 44 | Clamps for T/F |
| 45 | MS Angle ( T/F Base) 75x75x6x2028 MM |
| 46 | clamp for ss base |
| 47 | 11 kv fuse set |
| 48 | 11 KV TPMO |
| 49 | LT cable 3.5x70 Sq MM |
| 50 | LT Fuseset Protection unit with smc box |
| 51 | AL. Lug As per requirement |
| 52 | PART - B- WORK |
| 53 | Erection of Single pole structure on 9mtr ST. (SP-33) Pole for LT AB Cable hanging (As per site requirement double/Single circuit) including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40mm stone ballast), back filling of earth, proper ramming & fitting of all accessories LT ABC clamp, danger board with clamp.. Number plate with clamp. Aluminium paint, red oxide Paint, barbed wire, earthing |
| 54 | Erection of Single pole structure on 11mtr ST(SP-55) Pole for 11 KV O/H Line + LT single phase AB Cable composite line including & fitting of all accessories ('V' type cross arm 100 x 50 x 6 mm, clamps with bolt and nut, composite polymer pin insulator, danger board with clamp, Number plate with clamp, Pole painting, barbed wire earthing etc. complete). |
| 55 | Erection of Single pole structure on 11mtr ST(SP-55) Pole for 11 KV O/H Line + LT three phase AB Cable composite line including & fitting of all accessories ('V' type cross arm 100 x 50 x 6 mm, clamps with bolt and nut, composite polymer pin insulator, danger board with clamp, Number plate with clamp, Pole painting, barbed wire earthing etc. complete). |
| 56 | Erection of Single pole structure on 8.5 mtr PCC Pole for LT AB Cable hanging including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40mm stone ballast), back filling of earth, proper ramming & fitting of all accessories LT ABC clamp, danger board with clamp. Number plate with clamp. Aluminium paint, red oxide Paint, barbed wire, earthing |
| 57 | Erection of Single pole structure on 11mtr ST(SP-55) Pole for 11 KV S/C Line including all works of evocation of pit, pole erection, grouting in the ratio 1:4:8 (cement, sand, 40mm stone ballast), back filling of earth, proper ramming, making plinth for poles 30 cm above& fitting of all accessories (‘V' type cross arm 100 x 50 x 6 mm, clamps with bolt and nut, composite polymer pin insulator, danger board with clamp, Number plate with clamp, Pole painting, barbed wire earthing, etc. complete). |
| 58 | Double Pole on 8.5 mtr. long PCC Pole for 11 KV OH Line & TF Installation including all works of evocation of pit, pole erection, grouting in the ratio 1:4:8 (cement, sand, 40mm stone ballast), back filling of earth, proper ramming, making plinth for poles 30 cm above& fitting of all accessories (11 KV top channel, 11 KV droper channel,clamps with bolt and nut, composite polymer pin insulator, danger board with clamp, Number plate with clamp, Pole painting, barbed wire earthing, etc. complete). |
| 59 | Double Pole on 11 mtr. long ST Pole for 11 KV OH Line & TF Installation including all works of evocation of pit, pole erection, grouting in the ratio 1:4:8 (cement, sand, 40mm stone ballast), back filling of earth, proper ramming, making plinth for poles 30 cm above& fitting of all accessories (11 KV top channel, 11 KV droper channel,clamps with bolt and nut, composite polymer pin insulator, danger board with clamp, Number plate with clamp, Pole painting, barbed wire earthing, etc. complete). |
| 60 | Making of Sectional T-off Pole with all fitting complete work. |
| 61 | Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog/weasel conductor in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement in 03/06 Nos. conductor in parallel. |
| 62 | Guarding between two poles like single poles, double poles, four poles, etc. to guard LT, 11 KV Line telephone and river crossing, road crossing etc. with G.I. wire no. 6 SWG and G.I. wire no. 8 SWG, cutting, fabrication and fixing of guarding channel 75 x 40 x 3010 mm with clamps nut & bolts etc. as per drawing. |
| 63 | Labour charges complete for ABC Cable Laying. |
| 64 | Shifting, loading, carrage and installation of existing 25/16/10 KVA T/F 11/0.4 KV with related fitting. |
| 65 | Dismentling charges of existing PCC Pole 8.5 mtr. Long |
| 66 | Dismentling charges of existing ST Pole 9 mtr. Long |
| 67 | Dismentling charges of existing Rail pole |
| 68 | Dismentaling of old ACSR Dog conductor and rolling in pieces. |
| 69 | Dismentaling of old ACSR Weasel conductor and rolling in pieces. |
| 70 | Dismentaling of old & damage AB Cable1x16/3x50/3x95/3x120 sqmm and rolling in pieces. |
| 71 | Shifting, Loading, Carriage & Unloading of old and damaged 33KV/11 KV/LT Line materials from work site to Store centre Gorakhpur Distt. Gorakhpur. |
| 72 | Grouting of stay rods (16x1800) mm including all work of excavation, cement concrete in size (0.60 x 0.60 x 0.30) m in ratio 1:4:8 cement, sand, 40mm brick ballast) as per drg including back filling, proper ramming etc. Fixing tightening &nozzling of stay wire with stay rod with the poles of required tension as per drawing. |
| 73 | Special pipe earthing Please Enable Macros to View BoQ information |