| 1 | Cleaning/opening the blockage of sewer/sewage line of any size of bore/dia from gully traps, grease traps, Manholes, septic tanks etc. and upto 1.5mtr depth . The removing all filtn/silt, foreign materials and other deposits whatsoever completely, and making the line free from all obstacles and testing the flow of sewer/sewage line evenly, smoothly by filling water. The cleaning operation will be carried out in mechanical jetting machine/mannual labour and other suiatbale TNP equipments complete all as specified and dircted by Engr-in-Charge. Note : - 1. Length measured and paid by blocking between two manholes of sewer/sewage line complete. 2. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 2 | Cleaning/opening the blockage of sewer/sewage line of any size of bore/dia from gully traps, grease traps, Manholes, septic tanks etc. and exc 1.5 mtr but not exc 3.00 mtr depth . The removing all filtn/silt, foreign materials and other deposits whatsoever completely, and making the line free from all obstacles and testing the flow of sewer/sewage line evenly, smoothly by filling water. The cleaning operation will be carried out in mechanical jetting machine complete all as specified and dircted by Engr-in-Charge. Note : - 1. Length measured and paid by blocking between two manholes of sewer/sewage line complete. 2. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 3 | Cleaning/opening the blockage of sewer/sewage line of any size of bore/dia from gully traps, grease traps, Manholes, septic tanks etc. and exc 3.00 mtr but not exc 4.50 mtr depth . The removing all filtn/silt, foreign materials and other deposits whatsoever completely, and making the line free from all obstacles and testing the flow of sewer/sewage line evenly, smoothly by filling water. The cleaning operation will be carried out in mechanical jetting machine complete all as specified and dircted by Engr-in-Charge. Note : - 1. Length measured and paid by blocking between two manholes of sewer/sewage line complete. 2. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 4 | Cleaning/opening the blockage of sewer/sewage line of any size of bore/dia from gully traps, grease traps, Manholes, septic tanks etc. and exc 4.50mtr but not exc 6.00 mtr depth . The removing all filtn/silt, foreign materials and other deposits whatsoever completely, and making the line free from all obstacles and testing the flow of sewer/sewage line evenly, smoothly by filling water. The cleaning operation will be carried out in mechanical jetting machine complete all as specified and dircted by Engr-in-Charge. Note : - 1. Length measured and paid by blocking between two manholes of sewer/sewage line complete. 2. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 5 | Cleaning of manholes/septic tanks depth upto 1.5 mtr and upto 1.5 mtr dia etc. The removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the Manholes free from all obstacles and any other materials making clean and flushing with water complete.The cleaning operation will be carried out in mechanical jetting machine/mannual labour and other suiatbale TNP equipments complete all as specified and dircted by Engr-in-Charge. Note : - 1. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 6 | Cleaning of manholes/septic tanks depth exc 1.5 mtr but not exc 3.00 mtr and dia/size upto 2.00 mtr dia etc. The removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the Manholes free from all obstacles and any other materials making clean and flushing with water complete.The cleaning operation will be carried out in mechanical jetting machine complete all as specified and dircted by Engr-in-Charge. Note : - 1. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 7 | Cleaning of manholes/septic tanks depth exc 3.00mtr but not exc 4.50 mtr and dia/size upto 2.00 mtr dia etc. The removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the Manholes free from all obstacles and any other materials making clean and flushing with water complete.The cleaning operation will be carried out in mechanical jetting machine complete all as specified and dircted by Engr-in-Charge. Note : - 1. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 8 | Cleaning of manholes/septic tanks depth exc 4.50mtr but not exc 6.00 mtr and dia/size upto 2.00 mtr dia etc. The removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the Manholes free from all obstacles and any other materials making clean and flushing with water complete.The cleaning operation will be carried out in mechanical jetting machine complete all as specified and dircted by Engr-in-Charge. Note : - 1. Removing all filtn/silt, foreign materials and other deposits whatsoever completely out side of MD land in covered van/trolley complete. |
| 9 | Cleaning of all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, 100 mm/75 mm dia CI pipe stacks upto 1st Manhole, CI/SGSW pipe between gully trap & 1st Manhole, CI Tee/Door bends etc to maintain internal sewage system in the area of Mil Stn Gandhinagar and including manual/pressure cleaning pump & flexible rods and other necessary equipments complete all as specified and directed by Engr-in-Charge.Note : (i) Contractor or his authorised representative collect such type of complaints from AGE B/R Gandhinagar complaint cell at 8.30 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint.(ii) Complaint must be completed within 24 hours without any fail otherwise recovery shall be made double the market rate to the contractor. |
| 10 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed. |
| 11 | M&L for Brickwork with subclass ‘B’ bricks, (OLD SIZE BRICKS) straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified. |
| 12 | M&L for Brickwork with subclass ‘B’ bricks, (OLD SIZE BRICKS) (except bricks) straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified. |
| 13 | M&L for PCC 1:3:6 type C1 (using 20 mm gradded stone agg )as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings,parapets copings, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed. |
| 14 | M&L for cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately. |
| 15 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed. |
| 16 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked), finished even & smooth without using extra cement complete all as specified.Note : - Supply only water proofing admixture shall be measured and paid for separately. |
| 17 | M&L for rendering 15mm thick in cement plaster 1:4 on stone masonry surfaces or surfaces other than fair face of brick work of walls, mixed with water proofing admixture (ISI marked) finished even & smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately. |
| 18 | Supply only integral liquid water proofing compound (ISI marked). Make : Pidilite (Dr. Fixit Pidiproof LW) or equivalent of Fosroc / Sika / STP |
| 19 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified & directed by Engr-in-Charge. |
| 20 | Demolition of reinforced cement concrete (reinforced cut as required to facilitate demolition ) of any description and any position not otherwise spefically provided as in cover/slab of drain/culvert/septic tank/soakage well all a specified & directed by Engineer-in-Charge. |
| 21 | M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed.Note :- Reinforcement shall be measured and paid for separately. |
| 22 | M&L Mild steel TMT bars 8mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to TMT bar complete all as specified and directed by Engr-in-Charge. |
| 23 | Providing and laying 50mm thick for precast SFRC drain cover without frame but including complete sides iron sheets (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton /Sqm in circular/square/rectangular shape complete all as specified and directed by Engr-in-Charge.Note :- All Reinforcement and iron sheet including formwork,concrete complete the rate quoted by tenderer is deemed to included in item shall be made good by contractor without any extra cost to the Govt. |
| 24 | Demolition and breaking up drain pipes 150 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar pipes) complete all as specified and directed. |
| 25 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete. |
| 26 | M&L for 150mm dia DWCPE pipe (ISI Marked) of Class SN8 complete laid in trenches, for sewer networks laid on concrete bed and at any depth fixed and jointed with and including integral socket or coupler and EPDM sealing ring and tested complete all as specified in IS 16098-2013 complete all as specified anf directed. Note : Concrete bed measured and paid separetely in respective item |
| 27 | Demolition and breaking up drain pipes 200 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar pipes) complete all as specified and directed. |
| 28 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for 200 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete. |
| 29 | M&L for 200mm dia DWCPE pipe (ISI Marked) of Class SN8 complete laid in trenches, for sewer networks laid on concrete bed and at any depth fixed and jointed with and including integral socket or coupler and EPDM sealing ring and tested complete all as specified in IS 16098-2013 complete all as specified anf directed.Note : Concrete bed measured and paid separetely in respective item |
| 30 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out |
| 31 | Excavating in trenches, n exc 1.5 m wide, 1.5n deep but n exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out |
| 32 | M & L cement conc. 1:4:8 type D2 (40 mm graded aggregate) as in foundation, filling and mass conc complete all as specified. |
| 33 | Returning filling in including spreading, levelling watering and well ramming in layers not exc. 25 cm using excavated soil. |
| 34 | Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 35 | M&L for 150mm dia Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors including demolition old u/s pipe complete all as specified |
| 37 | S&F in repair 150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type `P' all as directed and specifed. Please Enable Macros to View BoQ information |