| 1 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed. |
| 2 | S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' type or 'J' type or cranked hook bolts and washers, in roof covering, walls cladding etc, with grade of zinc coating 275 complete all as specified and as directed. |
| 3 | S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 4 | S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in stepped flashing (measured as the minimum rectangle from which the piece can be cut) complete with grade of zinc coating 275 complete all as specified and as directed. |
| 5 | M&L Pre- painted aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed. |
| 6 | S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by AGE(I) having tensile strength of 550 Mpa as in ridges,valley complete all as specified and as directed. |
| 7 | Refixing only galvanised corrugated mild steel sheeting as obtained from dismantling of old sheets here in before with two corrugation side lap, fixed with & including 'L' type or 'J' type or cranked hook bolts in roof covering, wall cladding etc complete all as specified and as directed. |
| 8 | Refixing only plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) complete all as specified and as directed. |
| 9 | Refixing only plain, galvanised, mild steel sheeting, in stepped flashing (measured as the minimum rectangle from which the piece can be cut) complete all as specified and as directed. |
| 10 | M&L for Preparing old zinc (or galvanised) surfaces to recieve painting , by coating with two coat of synthetic enamel paint over a coat of red oxided zinc chorome primer complete all as specified and as directed. |
| 11 | S&F for 4mm thick, plywood (No. of ply3), grade BWR,type BB, fixed with nails to timber frame work on wall including taking out old plywood of any description complete all as specified and as directed. |
| 12 | S&F for 4mm thick , veneered decorative plywood (No. of ply3), grade 1 (with BWR resin) with decorative face veneers on one face; fixed with nails to timber frame work on wall including taking out old plywood of any description complete all as specified and as directed. |
| 13 | S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylone sleeves and screws at 450mm centre to centre/ intermidiate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and inculding ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermidiate channel with connecting clips across the intermidiate channel at 457mm centre to centre including 4mm thick non asbestos fibre cemet building boards fixed/laid to GI frame work and applying two coats of oil bound distemper including taking down old one, complete all as specified and as directed. |
| 14 | M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed work and including dismantling timber scantling 40Sqcm and over in section as in unframed work in any positioncomplete all as specified and as directed. |
| 15 | M & L for preparing new surfaces of wood and wood based materials of any description and girth, not otherwise described and applying two coats of creosote complete all as specified and directed. |
| 16 | M&L for weather boarding, 2nd class hard wood clean sawn, plain, 20 mm thick feather edged 15 mm to 20 mm thick and fixed with 30 mm laps and repairs to replace old or decayed boarding includind taking out old one complete all as specified and as directed. |
| 17 | S & F prelaminated particle board 18/19mm, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws as in pelmet box includind taking out old one complete all as specified and as directed. |
| 18 | S & F in repairs harrison rails 25mm dia , mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 19 | M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 20 | M&L for preparation of old painted steel surfaces of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed. Please Enable Macros to View BoQ information |