| 1 | Repairing of 02 no 40KVA Transformers |
| 2 | Cost of Super enameled Cu Wire Class H |
| 3 | Cost of Varnish for Air cooled Transformer |
| 4 | Cost of Thinner suitable for air cooled Transformer |
| 5 | Cost of Nomex Paper for Transformer Coil Insulation |
| 6 | Cost of GMP Tape |
| 7 | Deduction of cost of Scrap Copper Wire @ Rs.353/Kg |
| 8 | To and Fro Transportation |
| 9 | Service Charge (Labour Charge + PF @12.36%) |
| 10 | Profit @10% on consumable |
| 11 | Repairing of 02 nos. Welding Machine |
| 12 | Cost of Super enameled Cu Wire 8 gaug/4 mm |
| 13 | Cost of Insulating Materials |
| 14 | Cost of Glash Boards |
| 15 | Cost of Tap changers 400A |
| 16 | Cost of supply & fixing of studs |
| 17 | Deduction of cost of Scrap Copper Wire @Rs. 250/KG |
| 18 | Service Charge (Labour Charge + PF @12.36%) |
| 19 | Profit @10% on Consumable & Labour charge |
| 20 | Repairing of 01 no. Static Exciter |
| 21 | Copper Strip for primary coil |
| 22 | Copper strip for secondary coil |
| 23 | Insulation materials |
| 24 | Amp meter with shunt |
| 25 | Volt meter |
| 26 | Diode 150 amp |
| 27 | Fuse holder with fuse |
| 28 | Cooling Fan |
| 29 | Heat Sink mounting board |
| 30 | Heat Sink |
| 31 | Cost of body structure denting |
| 32 | Deduction of cost of Scrap Copper Strip |
| 33 | Service Charge (Labour Charge + PF @12.36%) |
| 34 | Profit @10% on Consumable & Labour charge |
| 35 | Repairing of 3.3 KV Field Switch |
| 36 | Earth Leakage relay (Digital) with CBCT 85-380V,0.03A |
| 37 | Auxiliary Contact 110 V |
| 38 | Charging coil set 110V DC |
| 39 | Tripping coil 110V DC |
| 40 | Ampmeter 3.3 KV |
| 41 | Indicator 8 Ampere |
| 42 | Support insulator |
| 43 | Outgoing insulator |
| 44 | Bus bar 6x40 m |
| 45 | Heat shrink tube 3.3/6.6 KV |
| 46 | Earthing arrester |
| 47 | Cost of wire,lugs,tapes,cleaning agent, nut, Bolt and Washer |
| 48 | Alluminium strip for earthing arrester |
| 49 | MS Channel 4\\" |
| 50 | Copper bus bar cutting, hole making and bending |
| 51 | Setting and Repairing OFVC Capsule |
| 52 | Replacement of Current Transformer |
| 53 | Repairing of mechanical rear and draw out System |
| 54 | Cost of Grousing electrodes |
| 55 | Cost of Ferroweld II |
| 56 | Cost of Steel electrode Durochrome |
| 57 | Cost of 24mm M.S. Steel Plate |
| 58 | Cost of Angle 50x50x6mm |
| 59 | Paint |
| 60 | Primer |
| 61 | Service charge (Labour Charge + PF @12.36%) |
| 62 | Profit @10% on Consumable & Labour charge |
| 63 | Welding machine charges |
| 64 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |