| 1 | The rate of supply of item is inclusive of Freight and insurance at site including loading & unloading. |
| 2 | PCC Poles 9 mtr long 400 Kg |
| 3 | 33 KV D/C Lattice Structure (42' ungalvanised with 3 Nos. 33 KV cross arm (Channel)) |
| 4 | ACSR DOG Conductor |
| 5 | 33 KV 3C X 300 Sqmm. HT XLPE Cable |
| 6 | 33 KV 3C X 300 Sqmm. Outdoor CABLE JOINTING KITS |
| 7 | 33 KV 630 Amps. Isolators with PI (With EB) |
| 8 | 33 KV Disc Insulator 45 KN B&S Type |
| 9 | 33 KV Disc Insulator H/W Set for 45 KN B&S Type |
| 10 | 33 KV Pin Insulator |
| 11 | 33 KV Galvanised MS Forged Pin |
| 12 | G.S. Stay Sets 20X2400 MM |
| 13 | 33 KV Stay Insulator |
| 14 | Stay Set Clamps suitable for 9mtr. Long PCC Poles |
| 15 | 1.8 Mtr. Channel Bracket with clamp |
| 16 | G.S. Earthwire 6 SWG |
| 17 | MS Rod Type Earthing Set with wire and clamp |
| 18 | PG Clamp for ACSR DOG Conductor |
| 19 | M.S. Channel 100X50X6 MM |
| 20 | Danger Plates |
| 21 | G.S. Stay Wire 7/8 SWG |
| 22 | Aluminium Lugs 300 Sqmm. |
| 23 | 33 KV CT/PT Structure |
| 24 | HT Meter Box |
| 25 | HT TVM with accuracy 0.2s with DLMS protocol |
| 26 | Control Cable 12C X 2.5 Sqmm |
| 27 | M.S. Angle 50X50X6 MM |
| 28 | 33 KV 800 Amps. Isolators with PI (W/o EB) |
| 29 | 33 KV CT-PT Set 200/5 Amps. |
| 30 | 33 KV CT-PT Set 50/5 Amps. |
| 31 | Trimming of tree branches/plants manually/ by machine and preparing route approchases for proposed line. |
| 32 | Excavation of pit in ordinary rock which does not require blasting/murrad (in Jodhpur discom) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. |
| 33 | (A) Height of poles/R.S.Joist/M.S. Rail /Size of pit |
| 34 | 9 Mtr/ 1.2mx0.6mx1.50 m deep |
| 35 | (B) Lattice Tower /Size of pit |
| 36 | 12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep |
| 37 | (C) Stay set/Depth of pit |
| 38 | 8'x 3/4\\" -0.75x0.5x1.6 m |
| 39 | Excavation of pit in Hard rock (Where blasting/drilling is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. |
| 40 | (A) Height of poles/R.S.Joist/M.S. Rail /Size of pit |
| 41 | 9 Mtr/ 1.2mx0.6mx1.50 m deep |
| 42 | (B) Lattice Tower /Size of pit |
| 43 | 12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep |
| 44 | (C) Stay set/Depth of pit |
| 45 | 8'x 3/4\\" -0.75x0.5x1.6 m |
| 46 | Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The cost muffing and grouting will be paid extra. |
| 47 | Lattice Structure |
| 48 | Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension. Size of stay set/stay wire |
| 49 | 8\\"x3/4\\" with 7/8 SWG stay wire |
| 50 | Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement, river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21 days in steel plates shuttering /farmer base. |
| 51 | Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs. |
| 52 | Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 Nos. disc. & 1set of H/W) on terminal point including fixing of hardware and strips. |
| 53 | Fixing of 33kv pin insulator with pins. |
| 54 | Fixing of danger plates on supports/structure |
| 55 | Fixing of PG clamp of Dog /Racoon Conductor |
| 56 | Assembly, Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. |
| 57 | (A) G.O. switch. with earthing blade. |
| 58 | 33kv G.O.switch |
| 59 | (B) G.O. switch. without earthing blade. |
| 60 | 33kv G.O.switch |
| 61 | Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / P.G.clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. |
| 62 | (B) IN RURAL AREA |
| 63 | ACSR DOG |
| 64 | Laying, jointing, stringing, tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc. including proper binding at each end. |
| 65 | (B) IN RURAL AREA |
| 66 | G.I.Earth wire 6 SWG |
| 67 | Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr. length as per design and requirment to be driven in earth by mechanical means and Providing & fastening of suitable clamps with the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil: |
| 68 | Where drilling is required |
| 69 | Providing and fixing of G.I. Pipe of 150 mm diameter. B-Class (IS:1239 mark), at the starting and finishing point of 33 KV under ground cables and to lay & clamp vertically with the existing support including labour charges. |
| 70 | Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper. (including cost of red oxide) |
| 71 | On new surface |
| 72 | Painting with aluminium paint of approved brand and manufacturer to give an even surface. (including cost aluminium paint) |
| 73 | On new works with two coats. |
| 74 | Laying of 33 KV XLPE Cable (Aluminium Conductor) underground as per relevant ISS / JVVNL standard including excavation of 30 cm width x120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn. |
| 75 | B) 3x240 Sq mm to 3x400 Sq mm |
| 76 | Intallation of 33 KV Cable (XLPE) termination / straight through joints (Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required. (Including crimping of lugs) Including required excavation/ removal/ fixing/ reaffixing/ testing etc. as required. |
| 77 | (i) Outdoor end terminal |
| 78 | (ii) 3x240 Sq mm to 3x400 Sq mm |
| 79 | Fixing and assembly of disc.point channel pair with pilot plates top hampers & clamps on erected single pole structure as per design. |
| 80 | 33 KV line |
| 81 | Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr. length as per design and requirment to be driven in earth by mechanical means and Providing & fastening of suitable clamps with the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil: |
| 82 | Where drilling is not required |
| 83 | Erection & fixing of steel struts in the excavated pit in position. The top end of the strut will be properly holed/welded with the main support muffed in cement concrete of ratio 1:3:6 as per item No.5.7. The cost of muffing and grouting will be paid extra. |
| 84 | P.C.C Poles 9 Meter(200Kg.) |
| 85 | Laying of 33 KV XLPE Cable (Aluminium Conductor) underground as per relevant ISS / JVVNL standard including excavation of 30 cm width x120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn. |
| 86 | Note:- Per mtr. Rate shall be paid extra for excavation of puccka road Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: SUPERINTENDING ENGINEER (TW), JVVNL, JAIPUR Name of Work: Execution of deposit works, including the Supply, Erection, Installation, Testing, and Commissioning of materials/equipment for the construction of 33/11 KV sub-stations, 33 KV & 11 KV overhead Line, laying of 33 KV and 11 KV underground XLPE Cable, construction of 33 KV Bay, 11 KV Bay and shifting of 33 KV & 11 KV line, Metering under Kota circle on turnkey basis against TW/TN-622. Contract No: JPD/SE(TW)/TW/TN-622 Name of the Bidder/ Bidding Firm / Company : ABSTRACT OF PRICE SCHEDULE FOR SUPPLY & ERECTION OF MATERIAL & EQUIPMENT(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) |
| 87 | Description |
| 88 | Quoted rate in BOQ1- SUPPLY OF MATERIAL AND EQUIPMENT |
| 89 | Quoted rate in BOQ2- ERECTION OF MATERIAL AND EQUIPMENT Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |